Installing/Replacing the Battery

Low battery is indicated by a red LED next to the battery symbol.

To replace the battery, remove the protective rubber boot carefully, 
taking care not to damage the SMB jack on the top of the pulse 
generator.

On the back of the unit there is a sliding panel. Push and slide this 
panel away from the device to remove it.

Remove the old battery.

Install the new battery, respecting the polarity indicated on the 
device.

Connecting the Cable to the CMAC 2504

An SMB-to-BNC cable is provided for connecting the CMAC 2504 
with the acoustic emission transducer.

Connect the SMB connector to the SMB jack on the CMAC 2504 by 
pushing the cable connector gently, but firmly onto the jack.

To remove the cable from the CMAC 2504, pull gently, but firmly 
on the cable connector.

Connecting the Cable to the Acoustic Emission 
Transducer

Connect the BNC end of the supplied cable to the acoustic emis-
sion transducer by connecting it to the transducer and twisting to 
secure the connection.

To remove the cable from the transducer, twist the cable connector 
and pull gently, but firmly on the cable connector.

SMB jack on the CMAC 2504 (left) and cable with SMB connector (right).

Acoustic emission transducer (left) and cable with BNC connector (right).

Injecting a Signal

Ensure that the CMAC 2504 device is connected to the transducer 
and powered on. Ensure the SKF Acoustic Emission Enveloping 
condition monitoring system is ready for signal acquisition.

Apply a thin, but even layer of couplant to the surface of the 
transducer.

The metallic surface that the transducer will be applied to should 
be flat and smooth and prepared so that all dust, residue and paint 
have been removed using sandpaper and surface cleaner (IPA), 
thus ensuring direct contact with the metal.

Press the transducer onto this surface to inject a signal into it and 
hold in place until several data samples of the system response 
have been recorded.

Apply couplant to transducer.

Press transducer onto surface.

3

Содержание CMAC 2504

Страница 1: ...CMAC 2504 Acoustic emission pulse generator User manual ...

Страница 2: ... contains refined peanut oil Please refer to the Material Safety Data Sheet MSDS Recommended use All installations of SKFAEE condition monitoring solutions must be validated before they can be commissioned The CMAC 2504 is rec ommended for the validation of SKFAEE condition monitoring sys tems including SKF Multilog On line IMx systems equipped with CMON 2504 AE interface cards and appropriate aco...

Страница 3: ...able to the acoustic emis sion transducer by connecting it to the transducer and twisting to secure the connection 2 To remove the cable from the transducer twist the cable connector and pull gently but firmly on the cable connector SMB jack on the CMAC 2504 left and cable with SMB connector right Acoustic emission transducer left and cable with BNC connector right Injecting a Signal 1 Ensure that...

Страница 4: ...sor Outer ring Inner ring Bearing seal 4 It is recommended that each acoustic emission sensor installation be validated by injecting a signal using the CMAC 2504 device at the following locations If the acoustic emission sensors are mounted on the inner ring then Immediately adjacent to the acoustic emission sensor in an axial direction into the inner ring At a position 90 along the inner ring in ...

Страница 5: ...S 786M dual sensor mounted on the axial face of the outer ring of the bear ing when a signal was injected by the CMAC 2504 into a location ad jacent to the sensor Note the strong pulse train in the time domain and also the clear 70 Hz peak plus harmonics in the spectrum Spectrum top and time waveform bottom of the acoustic emission response 5 ...

Страница 6: ...s Bearings and housings Lubrication systems Mechatronics Services The Power of Knowledge Engineering Combining products people and application specific knowledge SKF delivers innovative solutions to equipment manufacturers and pro duction facilities in every major industry world wide Having expertise in multiple competence areas supports SKF Life Cycle Management a proven approach to improving equ...

Отзывы: