The CMAC 2504 is a handheld, portable acoustic emission pulse 
generator used to inject a known signal into a machine instrumented 
with an SKF Acoustic Emission Enveloping (AEE) condition monitor-
ing systems. The system’s response to the signal is used to validate 
the installation. The CMAC 2504 generates a pulse train output with 
20 V amplitude, 2.0 

μ

s pulse width and a repetition frequency of 

~70 Hz. The AEE system response should be an attenuated pulse 
train with the same repetition frequency (~70 Hz). The presence of 
this response is sufficient to validate an AEE installation.

Features

•  Pulse train output with 20 V amplitude, 2.0 

μ

s pulse width and a 

repetition frequency of approximately ~70 Hz

•  LED indicators for on/off state and also for low battery condition
•  Estimated battery life > 100 hours for Lithium PP3 battery
•  Automatically turns off after 60 minutes to conserve battery life
• Handheld
• Portable
•  Rugged rubber boot
• Carry case

Components

•  Acoustic emission pulse generator base unit
•  9 V PP3 Lithium battery with rating 550 to 1 200 mAh
•  Protective rubber boot with stand/belt-clip
•  Signal cable (BNC to SMB)
•  Acoustic emission transducer
• Couplant gel*
•  Protective carrying case

*  Allergy warning: Couplant gel contains refined peanut oil.

 Please refer 

to the Material Safety Data Sheet (MSDS).

Recommended use

All installations of SKF AEE condition monitoring solutions must be 
validated before they can be commissioned. The CMAC 2504 is rec-
ommended for the validation of SKF AEE condition monitoring sys-
tems including SKF Multilog On-line IMx systems equipped with 
CMON 2504 AE interface cards and appropriate acoustic emission 
sensors. The CMAC 2504 can also be used to optimise sensor loca-
tions in advance of permanent installation by assessing the signal at-
tenuation for different sensor positions using the CMAC 2504 as an 
input stimulus.

Storage

When not being used, the CMAC 2504 should be stored in the 
provided carrying case. The device has been designed to withstand 
temperatures between –40 and +60 °C 

(–40 and +140 °F)

 and 

humidity levels of 10 to 90% relative (non-condensing) while in 
storage. For long term storage (i.e., > 3 months), it is recommended 
that the battery be removed from the unit.

Instruction guide

Turning the device On and Off

1 On

 – Press the red power button on the device membrane to turn 

the device on. A green LED, adjacent to the button, will light 
indicating that the device is on.

2 Off

 – Press the red button and hold for at least three seconds. The 

green LED will turn off, indicating that the device is powered off.

On/Off button

On state LED 

indicator (green)

Low battery LED 

indicator (red)

Carrying case.

2

Содержание CMAC 2504

Страница 1: ...CMAC 2504 Acoustic emission pulse generator User manual ...

Страница 2: ... contains refined peanut oil Please refer to the Material Safety Data Sheet MSDS Recommended use All installations of SKFAEE condition monitoring solutions must be validated before they can be commissioned The CMAC 2504 is rec ommended for the validation of SKFAEE condition monitoring sys tems including SKF Multilog On line IMx systems equipped with CMON 2504 AE interface cards and appropriate aco...

Страница 3: ...able to the acoustic emis sion transducer by connecting it to the transducer and twisting to secure the connection 2 To remove the cable from the transducer twist the cable connector and pull gently but firmly on the cable connector SMB jack on the CMAC 2504 left and cable with SMB connector right Acoustic emission transducer left and cable with BNC connector right Injecting a Signal 1 Ensure that...

Страница 4: ...sor Outer ring Inner ring Bearing seal 4 It is recommended that each acoustic emission sensor installation be validated by injecting a signal using the CMAC 2504 device at the following locations If the acoustic emission sensors are mounted on the inner ring then Immediately adjacent to the acoustic emission sensor in an axial direction into the inner ring At a position 90 along the inner ring in ...

Страница 5: ...S 786M dual sensor mounted on the axial face of the outer ring of the bear ing when a signal was injected by the CMAC 2504 into a location ad jacent to the sensor Note the strong pulse train in the time domain and also the clear 70 Hz peak plus harmonics in the spectrum Spectrum top and time waveform bottom of the acoustic emission response 5 ...

Страница 6: ...s Bearings and housings Lubrication systems Mechatronics Services The Power of Knowledge Engineering Combining products people and application specific knowledge SKF delivers innovative solutions to equipment manufacturers and pro duction facilities in every major industry world wide Having expertise in multiple competence areas supports SKF Life Cycle Management a proven approach to improving equ...

Отзывы: