Notice
Check gear rotation by turning
either gear.
If gears are not in mesh correctly or do
not rotate freely, remove one gear and re-
place correctly at 90° to other gear
(
† fig. 4
).
!
Notice
If gears do not turn or LED is not
blinking, perform assembly steps again.
Detector assembly
1
Align rib on top of cover (
2.1
) with “magnet”
on body (
1.1
) (
† fig. 4
).
2
Insert both gears at 90° angles to each
other (
† fig. 4
).
3
Lightly grease the o-ring (
1.4
) and place it in
the detector body (
1.1
).
Fig. 4
90°
1.4
2.1
7
1.1
1.3
1.2
4
Place cover (
2.1
) on detector body (
1.1
),
taking care not to damage o-ring (
1.4
).
5
Install washers and bolts (
2.3, 2.4
),
tightening bolts in a diagonal pattern to
0.73 ft.lbf
(1 Nm)
.
6
Visually check that the cover assembly (
2.1
)
has been pulled down evenly (
† fig. 4
).
Testing procedure
1
Apply 12 to 30 V DC to pin 1 and 3 of con-
nector (
† fig. 1 page 5
).
2
Apply low air pressure or pressurized
grease ( by grease gun, for example) to any
port of the detector.
3
As a result of this action, the gears should
turn, and LED should begin blinking.
6