EN
4. Technical data
- 10 -
951-150-032-EN
Version 09
4. Technical data
4.1 General technical data
General data
Designation
Dimensioned drawing
Field of application
Lubricant metering devices
Ambient temperature
[°C]
-40 ....+85
Principle of operation
Piston detector/position sensor
Material
Active area stainless steel (1.4404); housing stainless
steel (1.4016), plug: PEI
Mounting type
Mountable flush in the associated adapter
Tightening torque
[Nm]
7
±0.5
Circuit state display
LED
Yellow/lights up on damping
Electrical connection
M12x1 plug-in connection, gold-plated contact
Sensing range
Bipolar piston detector
sensing distance
[mm]
2.2 condition on delivery
Effective sensing distance (Sr)
[mm]
2.2 ±10%
Hysteresis
[% of Sr]
≤ 10
Accuracy/deviations
Switching point
[% of Sr]
±10%
Reproducibility
[% of Sr]
±10%
Permiss. operating pressure
with associated adapter
r
[bar]
Identical to permissible operating pressure of the
metering device in which the sensor with adapter is
installed (see metering device documentation).
8,5
15
M10x0,8
52
SW10
M12x1
8
8,7
3
LED
L+
L-
1 (4)
4(1)
4
1
3
2
2-wire DC PNP/NPN