PRODUCT SPECIFICATIONS
SKF Multilog On-line System IMx-Rail
20 (29)
SKF Multilog On-line System IMx-Rail
User Manual Supplement
Revision B
o
Aluminium cased
o
Isolated (input/output, input/case)
o
Continuous short circuit protection with automatic recovery
3.3.3 Analogue inputs
•
16 analogue single ended inputs, referenced to chassis/enclosure ground.
•
Channels 9 to 16 can connect to additional sensor types
o
PT1000, temperature probes (2-wire connection)
•
For further information refer IMx-16/IMx-16Plus user manual
3.3.4 Digital inputs
•
Four digital inputs, non-isolated, referenced to chassis/enclosure ground
•
For further information refer IMx-16/IMx-16Plus user manual
3.3.5 Digital outputs
•
Three: System status (RS), Warning and Alarm (R1 and R2)
•
For further information refer IMx-16/IMx-16Plus user manual
3.3.6 Analogue measurement
•
24-bit A/D conversion, one A/D converter for each channel
•
Maximum sampling frequency: 102.4 kHz (though lower for event capture)
•
Frequency range: from DC to 40 kHz
•
For further information refer IMx-16/IMx-16Plus user manual
3.3.7 Digital measurement
•
For further information refer IMx-16/IMx-16Plus user manual
3.3.8 Signal processing
•
Event capture mode
o
Data storage on time, associated measurement value or alarm state
o
Run cycle mode (used for rail track monitoring)
•
Rail Track monitoring
o
Supports @ptitude Observer’s Metro and Mainline modes
o
Measurements linked to GPS and speed data (as appropriate)
o
Continuous capture between two locations or when triggered
▪
At least 9.5 minutes of data at 1 kHz Fmax.
▪
Ready for new capture after 15 s (2-channels used)
•
For further information refer IMx-16/IMx-16Plus and/or @ptitude Observer
user manuals
3.3.9 Interfaces
•
Mobile data or Ethernet LAN (RJ45 or Wi-Fi)
o
LTE/GSM/Wi-Fi antenna is integral to the enclosure lid
o
Firmware configurable support for micro-SIM or eSIM
▪
Micro-SIM card holder (top end cap of IMx-16Plus)
o
One RJ45 port, 100 Mbit/s