Product does not start
LP gas tank valve is closed
Make sure regulator is securely attached to the LP gas tank per “Installing LP Gas
Tank,” then turn
LP gas tank valve to “OPEN.”
LP gas tank is low or empty
Exchange, refill or replace LP gas tank.
LP gas leak
1.
Turn LP gas
tank valve to “CLOSED.”
2.
Wait 5 minutes for gas to clear.
3.
Follow “Checking for Leaks” section.
Igniter does not work
1.
Turn off LP gas tank per “Turning Off” section.
2.
Press the igniter button (see figure 4).
a.
If you hear a clicking sound, igniter is working.
b.
Replace the “AA” battery (follow assembly step for inserting battery).
Too much air in hose line
1.
Connect LP gas tank per “Connecting LP Gas Tank” instructions.
Caution: Keep this appliance area clear and free from combustible materials,
gasoline, other flammable vapors and liquids and open flames.
2.
Turn LP gas tank valve slowly to “OPEN.”
3.
Press and hold control valve button for up to 3 minutes.
4.
Try and light the product
per “Lighting” instructions every 30 seconds until you
hear a “POP” sound indicating ignition.
5.
If still not working refer to “Regulator needs to be reset.”
Filter blocked
1.
Turn off LP gas tank per “Turning Off” instructions.
2.
Disconnect LP gas tank per “Disconnecting LP Gas Tank” instructions.
3.
Remove Regulator/Hose Assembly at product engine.
4.
Remove filter. Replace old filter with new filter.
5.
Reconnect Regulator/Hose Assembly at product engine.
6.
Perform leak check per “Checking for Leaks” instructions.
7.
Light product
per “Lighting” instructions.
Regulator needs to be reset
1.
Turn off LP gas tank per “Turning Off” instructions.
2.
Disconnect LP gas tank per “Disconnecting LP Gas Tank” section.