Operating Instructions

Cat. No. 228-9530

SKC Inc.

863 Valley View Road

Eighty Four, PA 15330 USA

Form 40079 Rev 1504

Содержание QuickTake 30

Страница 1: ...Operating Instructions Cat No 228 9530 SKC Inc 863 Valley View Road Eighty Four PA 15330 USA Form 40079 Rev 1504 ...

Страница 2: ...Guide 1 Description 3 Performance Profile 4 Battery Operation 6 Operation 10 Mounting Sampling Media 12 Calibration and Setting Flow 14 Setup 15 Sampling 17 Advanced Setup 19 Maintenance 23 Warranty 23 Ordering Information 24 ...

Страница 3: ...lays press to start sampling To Run or Hold Press To repeat a sample run From Done reset rSEt or sampling error SErr press to return to run time preset Press to sample To change or calibrate flow Note Flow rate does not appear on LED Press or and scroll to a run time preset Press and hold CAL for 2 seconds Does not require a security code Press or to change flow rate until desired flow appears on ...

Страница 4: ... of 1 to 999 minutes continuous run with manual shut off or intermittent sampling A rechargeable lithium ion battery pack provides effective run times see Performance Profile Typical Cumulative Run Time on page 4 Handle for easy portability Charging jack on side of case not shown High contrast LED display for readout of presets run time and battery status Calibration mode button Up arrow increases f...

Страница 5: ... 14 hrs at 10 L min battery only Sampling times when using spore traps are usually 10 min SKC recommends reducing length of sample time when using a 30 L min flow rate to prevent overloading the media Results obtained using a new pump and new fully charged batteries Pump and battery performance may vary The AC charger adapter can be used to extend battery run time but it is not a battery eliminato...

Страница 6: ...ge 18 for details Flow fault features are enabled as the default setting Flow fault may be disabled at the user s option See Advanced Setup Flow fault Flow fault displays immediately Pump shuts off after 5 seconds Fault restart Pump attempts restart every 10 seconds up to five times Media Compatibility Viable cascade impactors spore trap cassettes e g VersaTrap asbestos cassettes microvacuum casse...

Страница 7: ...pump for approximately 5 minutes before calibrating This ensures the battery is in more steady state conditions and improves the agreement in pre and post sampling calibrations The pump will not sleep during charging Connecting a sleeping pump to the charger will wake it up from sleep The AC charger adapter can be used to extend battery run time but it is not a battery eliminator Therefore it will...

Страница 8: ...e a Phillips head screwdriver to loosen the two screws with washers from the battery bracket Use forceps to remove screws and washers from the case set the screws aside Do not lose washers 5 Lift the bracket slightly slide it toward the case handle and lift it out of the case 6 Detach the battery from the battery harness by pressing on the connector tab left side of connector and pulling both side...

Страница 9: ... mounting tape available from SKC as Part No 51872 and apply to the bottom of the battery Remove the protective strip from the tape s remaining side to expose adhesive Ensure the battery harness wires on battery pack are facing away from the case handle before inserting battery in case 10 Align the battery in case as shown above before allowing the bottom of the battery to come into contact with a...

Страница 10: ...e pump in hazardous locations Use only the SKC approved battery and charger for this pump Use of an unapproved battery and or charger may damage the battery and the pump and voids any warranty To reduce risk of injury fire or electric shock always follow basic safety precautions when using this product Do not submerge the pump or subject it to any liquids Protect the sample pump from weather when ...

Страница 11: ...th the LED on press If battery status is low recharge the battery see Charging the Battery on page 6 Battery Status Indicators Full charge approximately 75 to 100 battery capacity remaining Battery is charged enough to operate the pump approximately 25 to 75 battery capacity remaining Battery charge is low charge battery approximately 1 to 25 battery capacity remaining Low Battery Fault Pump will ...

Страница 12: ...e LED by pressing and holding To interrupt a run terminate a sample or reset a pump From Hold press Sample reset rSEt will display Press to reset the pump or to ignore the reset and return to Hold To set flow or calibrate See Calibration and Setting Flow for details 1 Connect a calibrator to the pump inlet 2 Scroll to any run time preset Press and hold CAL for 2 seconds to enter calibration mode p...

Страница 13: ... adapter onto the spore trap cassette inlet seal removed attaching flexible tubing to the tube end of the second adapter and attaching the other end of the flexible tubing to the outlet of a calibrator Sampling Wand Accessory Cat No 228 9521 Insert the tube end of a cassette adapter into the hole on the top end of the sampling wand accessory see above up to the center flange Remove the seal from t...

Страница 14: ... over the right edge of the pump Align the hole on the short leg of the bracket with the hole on the side of the pump Secure the bracket to the pump with the thumbscrew 3 Insert the inlet adapter included with bracket into the pump inlet and connect the inlet adapter tubing to the BioStage outlet BioStage outlet Short leg of bracket Thumbscrew securing BioStage BioStage outlet aligned to 10 o cloc...

Страница 15: ... inch ID flexible tubing and appropriate adapters connect the inlet of the pump to the outlet of a representative sampling medium and a primary standard calibrator to the inlet of the representative sampling medium as shown above 2 Scroll to any run time preset Press and hold the CAL button for two seconds The pump will start running and a flashing CAL will appear on the LED 3 Press or to increase...

Страница 16: ...to zero run time remaining below one minute is displayed in seconds with a colon The pump will stop and beep four times The display will flash Done 3 Press to return to the run time preset display If the user wishes to repeat the sample press User Options During Timed Run Sampling Viewing battery status Press Display will automatically return to run time remaining after five seconds or press again...

Страница 17: ... will display cumulative run time and Hold alternately To continue the sample run Press To terminate the sample and reset the pump Press while in Hold Sample Reset rSEt will flash on the LED Press User Options During Continuous Run Sampling Viewing battery status Press Display will automatically return to cumulative run time after five seconds or press again Hold mode Press while the sample is run...

Страница 18: ...ount down to zero and the pump will stop The alarm will beep four times The display will flash Done Press to return to presets If a repeat sample is desired press b Continuous Run mode The timer will count up to 999 minutes automatically reset to zero and count again to 999 minutes until user stops the pump Press to place the pump in Hold when the desired sampling time has elapsed Hold and cumulat...

Страница 19: ...may disable feature If the pump is not able to compensate due to excessive back pressure a flashing FLOF will appear on the LED If the fault is not corrected within five seconds the pump will beep four times and stop running Restoring Sampling from a Flow Fault Fault restart manufacturer default enabled Fault restart will attempt to restart the pump every 10 seconds up to five times Cumulative run...

Страница 20: ... press to move to delay time 2 When finished press Stor will flash on the display To save the new setting Press Press to move to delay time setup To ignore the new setting Press Display will move to the delay time If displayed values are not changed the flashing Stor will not appear and pressing will move the display to the next parameter to be set Digital display Intermittent Sampling Digital dis...

Страница 21: ...red press to return to Intt 2 When finished press Stor will flash on the display To save the new setting Press Press to return to Intt To ignore the new setting Press The LED will return to Intt Start sampling by pressing The LED will count up to 59 seconds then switch to minutes up to the set minutes run time The pump will stop for the programmed number of delay minutes while the LED displays a c...

Страница 22: ...rst preset is selected Choosing End will truncate the stored preset sequence see below For example if the user desires to store only two presets preset time 3 can be set to End shortening the number of presets to scroll through Times programmed for preset times Pt 4 through 8 will not display until the presets are changed to make them display or the factory defaults are reset see Resetting Pump to...

Страница 23: ...lt Digital display Pump default Digital display No do not reset to pump default Enabling Disabling Alarm and Fault Features 1 Press the security code to enter setup mode 2 Press CAL The pump software version number will display briefly 3 Press or to turn feature on or off see below Press to advance to next feature 4 Press to exit feature setup Press again to return to run time presets Feature ON OF...

Страница 24: ...ewthecomplete SKC Limited Warranty and Return Policy go to http www skcinc com warranty asp Li Ion Battery Shipment Rechargeable lithium ion batteries for use with SKC sample pumps have been tested in accordance with the UN Manual and are proven to meet requirements of each test in the UN Manual of Test Criteria Part II subsection 38 3 They have a watt hour Wh rating below 100 Per 2013 IATA regula...

Страница 25: ... with inlet adapter calibration adapter rotameter and deluxe carry case 228 9530K Replacement Parts Replacement Inlet Filters pk 50 P40021A Stem Tubing Adapter pk 2 P31239 Cassette Adapter P33100 Reducing Adapter for Tubing 3 8 inch to 1 4 inch pk 2 P31211 Replacement Battery Pack P75689 Replacement Stack for QuickTake 30 P21266 Accessories Charger Adapter 100 240 V 223 245 Defender Primary Standa...