Changing Time/Date 

Change the time/date when moving between time zones in one of two ways: 

1.  Connect to the dosimeter(s) via the SKC SmartWave dB mobile app: the time/date will 

automatically be adjusted to the time/date on your phone.  

2.  Use DataTrac dB Software to adjust the time/date and upload the setting from the PC to the 

dosimeter(s) (

see DataTrac dB Software for NoiseCHEK User Manual

). 

Recording/Playing a Voice Note  

Record a voice note to identify details like 

the kind of noise being sampled, location of sampling, wearer’s 

job description, and other relevant items. You can upload and play a voice note on a PC using DataTrac 
dB Software. Only one voice note can be held in NoiseCHEK, and it must be deleted or uploaded to a PC 
before another note can be recorded.  

Note: Voice Note can be disabled in DataTrac dB software. See DataTrac dB Software for NoiseCHEK 
User Manual.  

1.  From the Home screen, press and hold the Voice button to begin recording a note. 

Note: Maximum recording time is approximately 44 seconds.

 

2.  End recording by pressing the Voice button again (otherwise it will be ended 

automatically when recording time exceeds maximum limit). 

See below

a. 

To save the recording

, select Home (press green button). The white LED 

will continue to flash intermittently (when dosimeter is powered on but not 
running) to indicate that a recording is present. If you try to record another 
note in the meantime, you will see the message that a recording is present. 

See Voice Note Status

b. 

To delete the recording

, select Delete (press red button). Select Yes (press green 

button) to confirm; the message that the recording has been deleted will appear. The 
white LED will stop flashing. 

See Voice Note Status. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Recording ended manually 

Recording stopped automatically 

 

Recording deleted 

Confirm deletion 

Содержание 701-001

Страница 1: ...he Battery 4 Notes and Cautions 6 Turning Power On Off 6 Determining Battery Charge Status 6 Microphone windscreen removed Windscreen Windscreen lock direction indicator Windscreen unlock direction indicator Voice Note button Clothing clip History button Previous button Windscreen LED collar Next button Screen Display Red button Power off stop select Green button Power on start select Clothing cli...

Страница 2: ...tus Icons 8 Changing Time Date 9 Recording Playing a Voice Note 9 Voice Note Status 10 Attaching NoiseCHEK on a Worker 10 Removing Reinstalling Windscreen 10 Operation 11 Performing a Sample Run 11 Calibrate 11 Sample 12 Post calibrate 13 Lock Feature 14 Reviewing Data History 14 Using DataTrac dB Software 15 Install DataTrac dB Software 16 Accessories Replacement Parts 17 Appendix Performance Pro...

Страница 3: ...hecking Dosimeter Kit Contents Use the table below to verify that you received all items associated with the Cat No ordered If you are missing items contact SKC at 800 725 8472 U S only or 724 941 9701 If you ordered Cat No Your package should contain 701 001 Dosimeter only requires charging dock see kits below or Accessories Replacement Parts 701 001K Single Kit includes dosimeter 1 unit Charging...

Страница 4: ...k b Plug power supply cube into 100 240 V power supply The power LED on the back of the dock will light up blue when connected to the power supply Note You can also charge NoiseCHEK by connecting the charging dock to your PC or a USB battery bank with a USB cable Charging time may increase significantly depending on the power available from the USB port used 2 Place the NoiseCHEK in the prepared c...

Страница 5: ...into a 100 240 V power supply The power LED on the back of the dock will light up blue when connected to the power supply Figure 2b Charging Train in Carry Case with Charging Cable Installed 2 Place the dosimeters in the prepared charging dock Battery charging status bars will be displayed on the dosimeter screens five amber LEDs will blink during charging Full charge is indicated by five green bl...

Страница 6: ...t Turn off From the Home or any Setup screen press and hold the red button Figure 1 Select YES press green button to confirm shutdown See below right Note After 5 minutes of inactivity NoiseCHEK will shut down automatically Determining Battery Charge Status The battery status icon is always displayed at the top left on the screen See the table below to determine the battery charge Battery Status I...

Страница 7: ...hing intermittently Communicating via Bluetooth with SKC SmartWave dB app Using the Buttons See the table below for how to use the dosimeter buttons Figure 1 to operate the device navigate screens and select screen prompts Button Functions Green Turn on device See Turning Power On Off Start run pause run and resume run Select prompts YES OK SELECT HOME RESUME LIST and digit in PIN for Lock feature...

Страница 8: ... has a Home screen with the following parameters set to the particular standard e g OSHA HC or PEL ACGIH MSHA HC or PEL or custom Exchange Exchange rate Threshold Criterion Criterion level Response Freq weight Frequency weight Octave bandwidth screens are displayed if enabled in DataTrac dB Software To view the parameter and bandwidth screens use the Previous Next buttons to scroll to them Note Fo...

Страница 9: ...e Voice Note can be disabled in DataTrac dB software See DataTrac dB Software for NoiseCHEK User Manual 1 From the Home screen press and hold the Voice button to begin recording a note Note Maximum recording time is approximately 44 seconds 2 End recording by pressing the Voice button again otherwise it will be ended automatically when recording time exceeds maximum limit See below a To save the r...

Страница 10: ...maximum sound Turn the wearer s head toward the dosimeter to make sure the chin does not touch the dosimeter 2 Fasten the clothing clips securely to the shirt See right 3 During sampling keep clothing from touching the windscreen to avoid contaminating results Removing Reinstalling Windscreen Remove windscreen Hold the windscreen collar with arrow on collar facing you turn it to the unlock indicat...

Страница 11: ...dscreen 3 Attach the AcoustiCHEK Class 2 114 dB calibrator on the microphone and turn on the calibrator by pressing the Power key 4 Press the Level key to set calibrator to 114 dB see calibrator operating instructions and Figure 3 After a 5 second countdown shown on the screen calibration will take place 5 When calibration is complete passed turn off or remove the calibrator from the microphone 6 ...

Страница 12: ...ing The run indicator will appear at the top right of the screen see below right a To pause sampling press and hold green button Select Yes press green button to confirm The pause indicator appears at top right on the screen See below Note If Auto Lock is enabled you will be prompted to enter the four digit PIN using the buttons on the dosimeter to select the PIN digits See Lock Feature NoiseCHEK ...

Страница 13: ...prompted to enter the four digit PIN See Lock Feature 5 Remove the device from the worker s shoulder Review sample history or return to Home screen by pressing the red button or History button 6 Proceed to Post calibrate Post calibrate Each time NoiseCHEK is calibrated it displays the calibration values obtained Before and After calibration and stores them For post calibration use the Before value...

Страница 14: ...T press green button Review data from the History views on the NoiseCHEK device on your PC using DataTrac dB software see Using DataTrac dB Software or on your mobile device using the SKC SmartWave dB mobile app Upload and print summary reports from PC or mobile app Upload a more detailed report compliance time history from your PC Note All the data needed to comply with OSHA is in the summary rep...

Страница 15: ...re lock and auto lock and more Figure 4 Schedule sample runs Upload data for viewing and or generating and sharing summary and compliance reports Figure 4 DataTrac dB Setup Screen When all four virtual dosimeters and octave band data logging are enabled and log data is set to 1 second it will take approximately 3 hours 1 3 octave or 1 hour 1 octave to download data accumulated during an 8 hour run...

Страница 16: ...alog datatrac DataTracdB setup exe or copy from USB drive setup exe and install DataTrac dB as instructed DataTrac dB will launch automatically The DataTrac dB Installer requires administrator privileges to install properly 3 Place noise dosimeter s in the charging dock to complete the communication train Figure 5 Note DataTrac dB will only detect dosimeters that are properly seated in the connect...

Страница 17: ... below 701 003 Power Supply for Charging Docks 100 240 V 220 600 AcoustiCHEK Calibrator Class 2 114 dB 703 002 Replacement Parts Cat No Replacement Windscreen 701 004 Replacement Microphone inch 701 005 SKC Limited Warranty and Return Policy SKC products are subject to the SKC Limited Warranty and Return Policy which provides SKC s sole liability and the buyer s exclusive remedy To view the comple...

Страница 18: ...ed Status LEDs Green amber blue and white LEDs provide visual indication of dosimeter status from a distance Security User selectable 4 digit PIN can be activated to secure access from mobile device and STOP PAUSE function on the dosimeter Connectivity USB to PC with DataTrac dB Software BLE to mobile device with SKC SmartWave dB app Battery Li Ion polymer rechargeable battery 3 7 V 1200 mAh Charg...

Отзывы: