Accessories/Replacement Parts (Cont)

Replacement Parts

Pump Case Parts

P21411 

Case Parts, excluding Battery Case

P21661MH 

Battery Pack Assembly, NiMH

P22417BC 

Belt Clip with screws

P22433N Keyboard 

Assembly

P22433U Control 

Board

P22433R 

Cap Screws, set of 2

P22433RS2 

Replacement Stack, does not include 

fl

 owmeter and 

fi

 lter housing assemblies or motor

P22417C 

Exhaust Port Fitting

Pump Stack Parts

P22417D 

Filter Housing Assembly

P22417E 

Pressure Switch Assembly

P22417F 

Valve Plate Assembly

P22417G Pump 

Body

P22417HC Diaphragm/Yoke 

Assembly

P22417J Regulator 

Assembly

P22417K 

Pulsation Dampener Assembly (2)

P22433L Flowmeter 

Assembly

Parts Not Shown in Illustration

P22433C Tamper-resistant 

Cover

P22433ES 

External Screw Kit

P72392 LCD
P22417M Motor/Eccentric 

Assembly

P5187 

Foam Cover for control board, pk/5

Replacement Filters

P22409 

Replacement Filter Set, 3 

fi

 lters/3 O-rings

P2240901 

Filters only, pk/10

P2240902 

Filter/O-ring Set, 100 

fi

 lters/10 O-rings

Pump Case Parts

Pump Stack (Cat. No. P22433RS2) Exploded

P22433R

P2243001

P22417BC

P21661MH

P22433U

P21411

P21411

P22433L

P22433RS2

(does not include 

fl

 owmeter and 

fi

 lter housing 

assemblies or 

motor)

P22433RS2

(does not include 

fl

 owmeter and 

fi

 lter housing 

assemblies or 

motor)

P22417F

P22417E

P22417HC

P22417G

P22417K

P22417J

P22417D

P22417C

Содержание 224-PCXR4

Страница 1: ...on Description The PCXR4 Universal Sample Pump Figure 1 is a constant flow from 5 to 5000 ml min air sampler suitable for a broad range of applications It is ideal for industrial hygiene studies as well as environmental testing Checking Pump Kit Contents Use the table below to verify that you received all items associated with the Cat No ordered If you are missing items contact SKC at 800 752 8472...

Страница 2: ... on the charger 3 Insert the charging plug end of the cable into the jack on the back of the pump s battery pack Figure 1 4 Charge the battery completely the LED at the port connected to the pump is a steady green before using the pump 5 Disconnect the charging cable from the back of the pump s battery pack Notes and Cautions To comply with intrinsic safety regulations do not charge or operate the...

Страница 3: ...mp operation with Battery Eliminator The Battery Eliminator is an accessory that converts alternating current AC to direct current DC from which the pump can be operated for extended runs The Battery Eliminator should be used in non hazardous locations only See Accessories 1 Remove the battery pack from the pump see Replace the Battery Pack 2 The Battery Eliminator is comprised of two pieces a wal...

Страница 4: ...stment screw until the built in rotameter indicates 2 L min The LCD should show BATT OK in the upper left corner If it does not recharge the battery 4 Press the Flow and Battery Check again to place the pump in Hold 5 Prepare the calibrator see calibrator instructions Using flexible tubing connect the calibrator outlet suction port to the sampling medium inlet 6 Using 1 4 inch Tygon tubing connect...

Страница 5: ...he pump into the air discharge port on top of the pump hand tighten only Using PTFE tubing connect the inlet of the sample medium e g sample bag to the exhaust port fitting on the pump Turn on the pump to collect the appropriate volume of air Shut off the pump and close inlet on sample medium to stop sampling 3 With the LCD displaying HOLD start sampling by pressing Start Hold Figure 1 SAMPLE RUNNI...

Страница 6: ...he battery is fully charged and that the pump has run for five minutes before calibrating Leave the pump running 2 Ensure that the regulator has been activated for low flow and the pump flow rate is set at 1 5 L min 3 Connect the single adjustable tube holder to the pump inlet see calibration train below using 1 4 inch Tygon tubing 4 Insert an opened sorbent tube into the rubber sleeve Figure 3 of...

Страница 7: ...tion 2 Place the appropriate size protective tube cover over the tube and screw it into place on the tube holder For personal sampling clip the tube holder to the worker in the breathing zone See above right 3 While the LCD displays HOLD start sampling by pressing Start Hold SAMPLE RUNNING will be displayed Figure 2 and record the start time 4 At the end of the sampling period press Start Hold and...

Страница 8: ...1 Ensure that the battery is fully charged and that the pump has run for five minutes before calibrating Leave pump running 2 Ensure that the regulator has been activated for low flow and the pump flow rate is set at 1 5 L min 3 Calculate the sum of all tube flow rates The maximum flow rate through any one tube is 500 ml min a If the sum is 1000 ml min set the pump flow rate to 1 5 L min b If the ...

Страница 9: ...Battery Eliminator in hazardous locations UL Listing for intrinsic safety is not in effect during pump operation with Battery Eliminator Use of any device other than the approved battery pack or Battery Eliminator to power the pump voids any warranty Charge pump battery completely before calibration and sampling Calibrate verify pump flow rate before and after each sampling operation using the tub...

Страница 10: ... use See Charge the Battery Pack For more information on SKC pump batteries visit http www skcinc com instructions 1756 pdf To comply with intrinsic safety regulations battery packs should not be charged in hazardous locations Ensure proper orientation of charging cable before plugging it into the charging jack Improper orientation contact will short circuit the battery and voids any warranty Shor...

Страница 11: ...tenance PowerFlex Charging System for SKC Personal Pumps 5 Stations 100 240 V 223 1000 Single 100 240 V 223 2000 PowerFlex Pump Cable for Universal XR models 223 1002 Battery Eliminator connects pump to line power for extended sampling 115 V 230 V 223 325 223 325B Pump Accessories Screwdriver Set included with pump 224 11 Protective Nylon Pouch with belt and shoulder strap Black 224 87 Red 224 95A...

Страница 12: ...hragm Yoke Assembly P22417J Regulator Assembly P22417K Pulsation Dampener Assembly 2 P22433L Flowmeter Assembly Parts Not Shown in Illustration P22433C Tamper resistant Cover P22433ES External Screw Kit P72392 LCD P22417M Motor Eccentric Assembly P5187 Foam Cover for control board pk 5 Replacement Filters P22409 Replacement Filter Set 3 filters 3 O rings P2240901 Filters only pk 10 P2240902 Filter...

Страница 13: ...sted for Class I Division 1 and 2 Groups A B C D Class II Division 1 and 2 Groups E F G and Class III Temperature Code T3C ATEX approved models available Contact SKC Operating Temperature 32 to 104 F 0 to 40 C Storage Temperature 4 to 113 F 20 to 45 C Charging Temperature 50 to 113 F 10 to 45 C Operating Humidity 0 to 95 non condensing Protect sample pump from weather when in use outdoors Multiple...

Страница 14: ...0 14 Polyvinyl Chloride PVC filter 5 0 μm pore size Flow Rate L min Filter Diameter 37 mm 25 mm 2 47 41 2 5 38 33 3 35 30 3 5 26 27 4 22 25 4 5 21 23 Table 1 Pump Run Time in Hours with NiMH Battery Appendix Cont Typical Run Times Table 1 contains the typical run times achieved when using a fully charged nickel metal hydride NiMH battery pack Data is sorted by type of sample media All run times ar...

Отзывы: