Sixnet Slim Line Switch Installation Guide
Page 30 of 33
SC or ST Fiber Ports: (100BaseF multimode or singlemode)
100BaseF ports
Up to 4
Fiber port mode
Multimode (mm) or Singlemode (sm)
Fiber port connector
Duplex SC or ST
Optimal fiber cable
50/125 or 62.5/125 µm for mm; 9/125 µm for sm
Center wavelength
1300 nm (other wavelengths available)
Multimode
Links up to 4 km typ.; 1310 nm; use with 50 or 62.5/125 um fiber
> Transmitter power (dB): -21 min, -17 typ, -14 max
> Receiver sensitivity (dB): -34 typ, -31 max
Singlemode
Links up to 20 km typical; 1310 nm; use with 9/125 um fiber
> Transmitter power (dB): -15 min, -11 typ, -8 max
> Receiver sensitivity (dB): -36 typ, -31 max
Singlemode long haul
Links up to 40 km typical; 1310 nm; use with 9/125 um fiber
> Transmitter power (dB): -5 min, -3 typ, -0 max
> Receiver sensitivity (dB): -36 typ, -34 max
Nominal max. distance (full
duplex)
(see web for details)
4 km with multimode;
20 km with singlemode;
up to 120 km with long haul singlemode
Half and full duplex
Full duplex on unmanaged models;
Software configurable on managed models
Ethernet compliance
100BaseF
Eye safety
IEC 60825-1, Class 1; FDA 21 CFR 1040.10 and 1040.11
SFP Mini-Gbic SFP (pluggable) Ports: (many types available)
Note:
On the Gigabit (MG) models these ports are pluggable and accept many different types of
pluggable SFP (Mini-Gbic) transceiver modules for Gigabit fiber connections.
Gigabit SFP ports
Up to 4
Port types supported
Gigabit fiber multimode, fiber singlemode, fiber long-haul
singlemode, fiber single-strand and more
Note: 100 Mbps fiber transceiver modules are also supported on these ports.
Fiber port connector
LC typically for fiber (depends on module)
Optimal fiber cable
Typical 50 or 62.5/125 µm for multimode (mm);
Typical 8 or 9/125 µm for singlemode (sm)
Fiber wavelength (typical)
850 nm for mm; 1310 nm for sm; 1550 for long haul sm
TX output power
See fiber transceiver datasheet for details.
RX input sensitivity
Max. distance (full duplex)
Up to 80+ km with long haul singlemode modules
Half and full duplex
Software Configurable
Ethernet compliance
1000BaseT and 1000BaseF (SX/LX/LH)
Eye safety
IEC 60825-1, Class 1; FDA 21 CFR 1040.10 and 1040.11
Note:
See SFP fiber optic transceiver datasheet for complete
specifications. Also, other fiber transceivers may be available for
special requirements such as longer distances, single strand (BiDi) or
other special applications.