background image

12

DISMANTLING PROTECTION  

5.1 

DISPLAY INFORMATION  

In accordance with international PCI regulations, the individual 
components of the davinci  VENDING terminal have been 
equipped with dismantling protection. This is intended to pre-
vent it from being dismantled and modified with malicious 

intent during operation, before then being put back into 
 operation. For this reason, the dismantled parts must always  
be returned to SIX Payment Services in order for these to  
be re  activated.

The dismantling protection consists of electronic contacts, 
which are located on the device front and can only be activated 
when the components are mounted correctly. Whether or not 

the dismantling protection of a component is active can be 
determined based on the status information shown on the 
 display:

DISPLAY

DESCRIPTION

HELP

Tampered (0) 
Tampered (2)

•  The security apparatus of the VENDING module was  triggered 

or tampered with

•  Return the VENDING module to  

SIX Payment Services

Reader Tampered (0) 
Reader Tampered (2)

•  The security apparatus of the reader was  triggered  

or  damaged

•  Return the reader to SIX  Payment Services

Not mounted (4)

•  The VENDING module is not mounted correctly

•  Check the contacts on the  dismantling  protection
•  Activation possible  following correct mounting

Reader not mounted (4) • The reader is not mounted correctly

• The mouthpiece is not mounted correctly

•  Activation possible  following correct mounting
•  You may need to check the contacts on the dis-

mantling protection and/or the  mouthpiece mount

Not activated (5)

•  The dismantling protection for the VENDING  module  

has not been activated

•  Carry out activation

Reader not activated (5) •  The dismantling protection for the reader has not  

yet been activated

•  Carry out activation

Not mounted (7)

•  The VENDING module is not mounted correctly
•  The VENDING module was removed

•  Device must be returned to  

SIX Payment Services for  reactivation

Reader not mounted (7) •  The reader is not mounted correctly

•  The reader was removed
•  The mouthpiece is not mounted correctly

•  Device must be returned to  

SIX Payment Services for  reactivation

Not activated (8)

•  The dismantling protection for the VENDING module has been 

re-closed

•  A password is required for its reactivation
•  Whilst it is in this state, no transactions are possible

•  Device must be returned to  

SIX Payment Services for  reactivation

Reader not activated (8) •  The dismantling protection for the reader has been re-closed

•  A password is required for its reactivation
•  Whilst it is in this state, no transactions are possible

•  Device must be returned to  

SIX Payment Services for  reactivation

Содержание Worldline DAVINCI III

Страница 1: ...INTEGRATION GUIDE DAVINCI III VENDING...

Страница 2: ...6 PIN ASSIGNMENT FOR THE CONNECTORS 9 2 6 1 PIN ASSIGNMENT FOR THE DAVINCI III VENDING MODULE 9 2 6 2 PIN ASSIGNMENT FOR THE CARD READERS 9 2 6 3 PIN ASSIGNMENT FOR THE RFID READER 9 2 7 EARTH 9 3 TER...

Страница 3: ...may occur that lead to deviations from these instructions SIX Payment Services shall therefore accept no liability for the up to dateness completeness or accuracy of the information provided in these...

Страница 4: ...lies to the 4 screws that hold the mouthpiece module together The external 4 screws affixing the reader to the device front may have a maximum torque of 0 3 Nm for the final tightening step Figure Cut...

Страница 5: ...therwise the dismantling protection may be triggered The contact area for the dismantling protection switch must be flat Welding studs M5 4x DEVICE FRONT CUTOUT The VENDING module is mounted to the de...

Страница 6: ...ader 6 2 3 INSTALLING THE CONTACT CARD SLOT READER To begin with the mouthpiece and the retainer plate are mounted to the device front step 1 The retainer plate features channels to carry away water T...

Страница 7: ...2 1 7 2 4 INSTALLING THE RFID READER The RFID reader is affixed to the device front as follows Open and remove the mounting frame Figure Mounting the RFID reader Figure Dismantling the RFID reader...

Страница 8: ...is powered using the hybrid slot reader a mains adapter or a vending machine In such instances additional components can also be powered simul In the version displayed the davinci III VENDING module...

Страница 9: ...N ASSIGNMENT FOR THE RFID READER 2 7 EARTH It must be ensured that the correct earth is in place between the davinci III VENDING module and the slot reader Figure Earthing example davinci III VENDING...

Страница 10: ...directly via LAN IP Configuration DHCP Obtains the IP address from the DHCP server and displays it continue with OK Static IP Must also be stated and prepared upon activation accordingly Server lP Add...

Страница 11: ...be pressed as the white screen is being set up Thereafter the user is requested to enter the Z password MENU ITEMS 1 Test PIN pad Every button must be pressed 1x 2 Test external reader The card is re...

Страница 12: ...the dismantling protection Activation possible following correct mounting Reader not mounted 4 The reader is not mounted correctly The mouthpiece is not mounted correctly Activation possible following...

Страница 13: ...to execute Plaintext PIN verifications against chip cards which have an SDA chip static data authentication These would then under certain circumstances no longer function correctly The Swiss Maestro...

Страница 14: ...14 6 DAVINCI SAFE Assembly instructions for the davinci SAFE terminal Unlocking Housing Loosen the 4 nuts Base plate assembly Upper bracket Open housing Attention consider the direction...

Страница 15: ...six payment services com worldline com 110 0653 02 INT_EN 11 2020 YOUR LOCAL POINT OF CONTACT CAN BE FOUND AT six payment services com contact...

Отзывы: