HEATER POSITIONING 

1. Position heater at least 200mm from the eave lining or 

ceiling or wall at 90˚ to heater.

2. Position heater at least 1.8m above the floor.
3. Never position in front, above or below a power point.
4. If heater is facing another vertical surface, example – 

wall, the gap must be at least 1 metre.

5. Never mount heater within 1 metre of a water source, 

example – tap.

NOTE: Never mount heater into the wall or ceiling. Only 
mount to the surface.

eave/ceiling

floor

1.8 m

wall

eave/ceiling

minimum 1.8m

wall

200mm

90°

1m minimum

200mm

floor

wall

heater

NO

eave/ceiling

heater

1.8m minimum

NO

Содержание Gasmate OPTIMUM EH600 Series

Страница 1: ...ES Important Retain these instructions for future use 03841 11 18 Metal radiant heater with non glowing element Adjustable wall and ceiling bracket Black anodised aluminium 1 5m long power cord Designed for indoor and outdoor use Ideal for use in alfresco areas verandahs and garages EH633 EH633R requires 15A power point to be installed by qualified electrician ...

Страница 2: ...is NOT designed to run off an extension cord If you require an additional power point please have one installed by a qualified electrician The use of extension cords may cause power voltage loss which will result in damage to the appliance this will NOT be covered under warranty Installation Always ensure you select the correct fixing accessories which suit the particular wall ceiling material you...

Страница 3: ...le system with this heater DO NOT clean the heater while the heater is on or plugged into the mains power supply DO NOT touch any part of the heater while on hot surfaces may burn DO NOT use the wall heater as a dryer DO NOT attempt to modify the heater power cord power plug or the supplied accessories in any way DO NOT expose the heater to rain water or use in damp wet conditions NEVER cover this...

Страница 4: ...allation of a 15AMP socket by a qualified electrician before use TECHNICAL SPECIFICATION MODEL EH613 EH613R B EH623 EH623R B EH633 EH633R B Remote Control No Yes No Yes No Yes Voltage 220 240V AC 50Hz 220 240V AC 50Hz 220 240V AC 50Hz Input Wattage 1800W 2400W 3200W 15AMP Unit Weight 6 8Kg 7 5Kg 7 5Kg 8 2Kg 9 0Kg 9 7Kg IP Rating IPx4 IPx4 IPx4 Heater specifications can be found on the data label B...

Страница 5: ...nt of a power point 3 Mark and drill 2 mounting holes for bracket C 4 Using 2 suitable screws not supplied attach the bracket to the wall or ceiling Note If unsure what screws to use please discuss with your local hardware store 5 Using the nuts and bolts join the bracket C to the heater bracket B and tighten fully 6 Heater is now mounted and ready for use Check the safety distance between the hea...

Страница 6: ...eved 5 Insert and tighten the locking bolt if possible to stop any unintentional movement of the heater Note If locking bolt can not be fitted ensure the head tilt bolt is very tight Head Tilt Bolt 30 CEILING MOUNT WITH CHAIN Only use this mounting option if your ceiling is too high 1 Attach the bracket C as noted below 2 Cut chain D not supplied to desired length 3 Using nut and bolt attach chain...

Страница 7: ...elow a power point 4 If heater is facing another vertical surface example wall the gap must be at least 1 metre 5 Never mount heater within 1 metre of a water source example tap NOTE Never mount heater into the wall or ceiling Only mount to the surface eave ceiling floor 1 8 m wall eave ceiling minimum 1 8m wall 200mm 90 1m minimum 200mm floor wall heater NO eave ceiling heater 1 8m minimum NO ...

Страница 8: ...e unit switch on it will glow Red Standby Function On 4 Using the remote press ON the heater will come on and a small blue LED will glow Turn OFF 1 Using the remote press OFF the heater will turn off and the small LED light will go out 2 Turn the unit switch off the red LED will go out 3 Switch the wall socket off 4 Unplug the lead from the wall socket when not in use CLEANING Always ensure that t...

Отзывы: