E)  Structural polymer unions of high strength and durability. 
F)  Rubberized casters with 200mm diameter and brake system. 
G)  33 density mattress, coated in 100% waterproof material, electronically sewn. 
H)  Tilting side handles with double trigger. 
I)  Anti-fall safety system. 
J)  Hard tubular aluminum structure. 
K)  Articulated polymer joints. 
L)  Adjustable backrest (fowler) with 8 adjusting positions.

 

 

M)  Front stoppers coated with high impact PVC profile. 
N)  Air-axle with rubberized casters and height adjustment system. 
O)  Custom electrostatic painting on lower frame (optional). 
 
 
 
 
 
Applies to MRS 340 – TOP MOTION the same instructions presented for the MRS 310 – ESSENTIAL, except for cleaning and disinfecting 
the parts that have electrostatic painting. This should be done using only a damp cloth, without the use of any abrasive product. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
PARTS AND FEATURES 
 
A)  
Safety belts with automotive couplings. 
B)  33 density mattress, coated in 100% waterproof material, electronically sewn. 
C)  Hard tubular aluminum structure. 
D)  Rubberized casters with 127mm diameter and brake system. 
E)  Structural polymer unions of high strength and durability. 
F)  Adjustable backrest (fowler) with 8 adjusting positions. 
G)  Tilting side handles. 
 
 
 
 
 
Applies to MSS 300 – PRIME CARE the same instructions presented for the MRS 310 – ESSENTIAL, with the exception of the retractable 
system operation, as PRIME CARE model is devoid of such feature. The operation of this model should be performed as follows. 
 
1. Since it doesn’t have retractable legs, all movement of the PRIME CARE model should be performed in the ground. 2. The transport and 
movement of placing or withdrawing it from the interior of the ambulance (3) must always be carried out by at least two rescuers. 

STANDARD COT MSS 300 – PRIME CARE 

C

B

A

D

E

G

F

USAGE INSTRUCTIONS 

USAGE INSTRUCTIONS 

Содержание MCS 200

Страница 1: ...or any content without the written consent of Sitmed SUMMARY DISCLAIMER 1 GENERAL INFORMATION 2 LIABILITY LIMITS 2 ATTENTION 2 FIRST AID POPULAR CONCEPT 2 PACKAGING AND STORAGE 2 EQUIPMENT S LIST 3 IDENTIFICATION AND TRACEABILITY 3 VISUAL COMMUNICATION 3 WARNINGS 4 RESCUE CHAIR MCS 200 ÁGILA 5 IMMOBILIZATION BOARD MIS 100 MEDUSE 7 FOLDABLE STRETCHER MPS 110 PANDORA 8 BI FOLDABLE STRETCHER MPS 120 ...

Страница 2: ...s well as modifying the equipment by altering the original design generates risk of accidents and loss of warranty as well as the consequent liability of the owner for the damages it may cause Use only original parts provided by Sitmed and before servicing read this manual or contact Sitmed Technical Service for guidance and clarification Before using the equipment make sure that it is in perfect ...

Страница 3: ...l which features model and reference number for tracking control To prevent loss wear and commitment in identifying serial equipment labels are affixed to hard to reach places yet easy viewing Look for the serial label on the bottom of your device to find the correct model you have so you can refer to the instructions in this manual Figure 1 Serial label template affixed to all Sitmed devices VISU...

Страница 4: ... the load limit stipulated for each equipment Sanitize the same periodically or after each use Follow the preventive maintenance schedule performing the same according to the instructions in this manual All products and components used by Sitmed are recyclable Before disposing of parts or unused equipment check the need for disinfection or sterilization of the same If there is any doubt or difficu...

Страница 5: ...nder handle H Footrest base I Fastener system for ambulances J Rubberized casters with 127mm diameter and brake system 1 Open the chair by pulling the arm and disarm bar F 2 Lock the arm and disarm bar and pushing it until the end of its course 3 Lower the armrest D lift the foldable arms B lower the footrest H and extend the extensor levers G as required RESCUE CHAIR MCS 200 ÁGILA A D G H J E C B...

Страница 6: ...le B 02 Plastic stoppers C 02 5 16 Plater washer D 04 M6 X 25 self tapping screws E 02 M8 Pressure washers F 02 M8 Nuts G 02 M8 X 65 Screws 1 To install the chair find a spot inside the ambulance where it can stand without any obstruction 2 Attach the locking turtle A to the king pin and the plastic stoppers B in the rear couplers affixed to the chair 3 Attach the assembly to the ambulance wall an...

Страница 7: ...s 1 2 3 and 4 Depending on the patient s weight two rescuers additional help may be necessary as they can be placed as illustrated at positions A and B Figure A Block transfer Lift the patient by keeping the spine stabilized and lying on the board Figure B 90 degrees rolling Roll the patient sideways keeping the spine stabilized placing the board underneath the patient and roll him back to the ori...

Страница 8: ...opening or closing 2 Lay the patient on the stretcher whether or not immobilized to the immobilization board 3 Before transporting someone lock the patient with the seat belts B adjusting the buckle to ensure its stability FOLDABLE STRETCHER MPS 110 PANDORA D C A B E OPERATING INSTRUCTIONS 1 3 The MPS 110 PANDORA stretcher has a flexible synthetic base and it is not recommended to transport patien...

Страница 9: ...tcher folding it lengthwise 4 Fold the stretcher 5 Store the stretcher inside its bag for transport BI FOLDABLE STRETCHER MPS 120 PANDORA 2 A B D C E F G OPERATING INSTRUCTIONS The MPS 120 PANDORA 2 stretcher has a flexible synthetic base and it is not recommended to transport patients with suspected cervical spine injury without being properly immobilized with a rigid board Do not use the stretch...

Страница 10: ...M Adjustable backrest fowler with 8 adjusting positions N Air axle with rubberized casters and height adjustment system 1 Wheel brake To lock the wheels step on the bottom of the yellow part A and to release step on the top B 2 Double trigger side handles Press the top of the yellow trigger C simultaneously on both sides lowering the handle To close again simply return to the original position The...

Страница 11: ...ve them or to put them in the cot pass the couplings inside the base handle trapping it in the structure of the cot The cot ambulance fastener installation kit contains the following items A 01 Aluminum V guide with stoppers B 01 Locking turtle with adjusting rail C 08 M8 pressure washer D 08 M8 X 65 Screws E 08 Plater washer 5 16 F 08 M6 X 50 self tapping screw G 08 M8 nuts The first step for ins...

Страница 12: ...m and still After fixing the sets its necessary to perform a fine adjustment of the king pin and the locking turtle Test the cot anchorage by placing and pulling it out of its fastener with and without weight The perfect attachment consists of the simultaneous locking of the king pin on the turtle and the pins of the air axle on the frontal guide stoppers If necessary adjust the height of king pin...

Страница 13: ...ng it in a 100 horizontal position until it is attached to the fastener system Pull the cot to make sure it is securely attached to its fastener 4 To remove the cot from inside the ambulance suspend the cot with one hand and use the other hand to trigger the locking turtle 5 Press the locking turtle lever down releasing the king pin 6 Pull the stretcher back holding the locking turtle lever until ...

Страница 14: ...e operated by four rescuers placed in positions as indicated in the image PARTS AND FEATURES A Movable or fixed rear handle for transport B Steel set with king pin to lock on rear fastener C Polymer retraction lever D Safety belts with automotive couplings RETRACTILE COT MRS 340 TOP MOTION A D H L G E B I C F J M N K O Be alert when removing the cot from the ambulance while it is parked on steep o...

Страница 15: ...damp cloth without the use of any abrasive product PARTS AND FEATURES A Safety belts with automotive couplings B 33 density mattress coated in 100 waterproof material electronically sewn C Hard tubular aluminum structure D Rubberized casters with 127mm diameter and brake system E Structural polymer unions of high strength and durability F Adjustable backrest fowler with 8 adjusting positions G Til...

Страница 16: ... 100 waterproof material electronically sewn G Structural polymer unions of high strength and durability H Additional 3 casters for ground support I Tilting side handles with double trigger J Anti fall safety system K Articulated polymer joints L Hard tubular aluminum structure M Adjustable backrest fowler with 8 adjusting positions N Front stoppers coated with high impact PVC profile O Air axle w...

Страница 17: ...ulance 6 until it locks to the fastener system The IV Pole and the O cylinder holder are both sold separately and may be attached to the Sitmed stretchers In the case of your stretcher having one of those accessories please proceed as follows IV POLE 1 Arm the bracket lifting the rod A in position 90 degrees until the yellow trigger automatically locks into the base of the bracket 2 Open the hitch...

Страница 18: ...ried inside the ambulance D To install the clip choose a free wall inside the ambulance brace the clip on the wall mark the hole and secure with the supplied hardware PARTS AND FEATURES A Slim lightweight and compact B Additional support casters C Rubber castors with a diameter of 127mm and a brake system D Safety belts with automotive locks E Mattress density 33 coated in 100 waterproof material ...

Страница 19: ... To remove the cot from the ambulance release it from the fasten system by pressing the locking lug as per instructions in this manual Pull the cot out of the ambulance without pulling any levers suspending the patient s weight and keeping the cot 100 level in the horizontal position Pull it until both legs lower by gravity and the telescopic system locks automatically INDEPENDENT RETRACTION SYSTE...

Страница 20: ...est in second position use your both hands to pull up the straps E until the hooks clip in the under cavity F To back to the original position just pull up the system using your both hands G MULTI POSITIONS SYSTEM If your cot has the multi positions system you can use it to put the patient in several positions including Fowler position Trendelenburg and RCP position To put the patient in fowler po...

Страница 21: ...e Med Rac as accessory The Med Rac are used as support for devices such as Monitors infusion pumps desfibrilators and others up to 30Kg To use your Med Rac you must open the side bases A loosening all gauntlets B in both sides Open the bases until the end and tight the gauntlets At this moment your Med Rac will look as a table C To fasten the equipment on the Med Rac use the velcro straps D adjust...

Страница 22: ... with the cot in elevated position The blue area indicate where is possible the patient sit on the cot ADDITIONAL SAFETY SYSTEM Level Up II has a system that prevents accidental fall When unloading from the ambulance the system will set automatically making it impossible to pull the retraction levers To fold the legs to loading the cot into the ambulance use your thumb A and push the red lever out...

Страница 23: ...hic articulation system X with height adjustment levels K Base in leaked plot for accessories transport with 15kg load capacity L Safety belts with automotive couplings M Adjustable backrest Fowler with 8 adjusting positions N Folding bed for transport in elevators and confined spaces O Air axle with rubberized casters and height adjustment system The cot ambulance fastener installation kit contai...

Страница 24: ...try of the ambulance aligned with the fastener system so that there is room for the wheels frame to rise and fall freely 3 Attach the safety hook A on the movable bar B taking into account the movement of the bar causing it to be tensioned Mark the holes C remove the safety hook and the cot drill the marked holes be careful that the location chosen for the hook positioning does not compromise or d...

Страница 25: ...onsists of raising his feet to at least 30 centimeters above the floor This position is called shock position This helps to keep the blood in vital organs where it is most needed 2 The MXS 330 ELEVEX cot makes it possible to place the patient in the shock position by activating the telescopic system similar to the movable backrest which is located under the patient s legs Pull the yellow trigger A...

Страница 26: ...he anti recoil system A Pull the cot to be sure that it is fully engaged at the safety hook B 2 Lift the weight of the cot patient and pull the rear handle 3 Na additional rescuer C must be placed at one side of the cot to manually raise the wheels frame 4 Push the cot inside the ambulance until it gets locked on the fasteners 5 To remove the cot from inside the ambulance unlatch the king pin from...

Страница 27: ...Components or loose parts with excessive wear and tear If bolts and nuts are tight and in their respective places Elastic pins out of position If casters are freely rotating and braking when brakes are triggered If all movable parts are correctly moving If the backrest is working in all tilt levels If the mattress is sanitized and free of perforations If the safety belts are sanitized well tight a...

Страница 28: ...following schedule to perform periodic maintenance of your equipment thus ensuring its longest life and safety MONTH DATE RESPONSIBLE SHIFT VTR Nº NOTES JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC MONT DATE RESPONSIBLE SHIFT VTR Nº NOTES JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ...

Страница 29: ...e city of Flores da Cunha Brazil The buyer residing in another location will therefore be solely responsible for the costs and risks of the equipment transportation Warranty is valid only if duly proven defective manufacturing It will be necessary to prove the ownership of the equipment and the warranty period through the serial number and invoice of purchase of the equipment For full control of y...