They do not sense heat, flame, or gas. This smoke alarm
device is designed to give audible warning of a developing
fire. However, many fires are fast - burning, explosive, or
intentional, and others are caused by carelessness or safety
hazards. In this circs, Smoke may not remake the unit
alarm
QUICKLY ENOUGH
to ensure safe escape.
7:Smoke alarm devices have limitations. This smoke alarm
device is not foolproof and is not warranted to protect lives
or property from fire. Smoke alarm devices are not a
substitute for insurance. Homeowners and renters should
insure their lives and property. In addition, it is possible for
the smoke alarm device to fail at any time. For this reason,
you must test the smoke alarm device weekly and replace
unit every 10 years.
Battery Connections:
Diagram 2
Battery Specification:
Carbon Zinc
Battery
:
Gold Peak:GP1604S 9V by GP International (Shen
zhen).LTD
Replace Battery:
1: Turn the alarm body counterclockwise and take out the
alarm body from the bracket.
2: Take out the old battery, connect the new battery to power
connector.
3: Fix the battery into battery box, fit alarm body on bracket
and turn the alarm body clockwise.(see Diagram 3).
4: Test smoke alarm using test button. The sound
pattern is 3 short beeps-pause 1.5 seconds, repeat it.
If there’s no sound output, it means that the smoke
alarm is faulty or the installing operation is wrong,
and you can get helps from the section: “trouble
shooting”.
WARNING:
Test the alarm for correct operation
using the test facility whenever the battery is replaced.
Diagram 3
Do Not Install Smoke alarm devices in
the Following Places:
1:Near appliances or areas where normal combustion
Regularly occurs (kitchens, near furnaces, hot water
heaters).Use specialized smoke alarm device with
unwanted alarm control for this areas.
2:In areas with high humidity, like bathrooms or areas near
dishwashers or washing machines. Install at least 10feet
away from these areas.
3:Near air returns or heating and cooling supply vents. Install
at least 3 feet away from these areas. The air could blow
smoke away from the detector, interrupting its alarm.
4:In rooms where temperatures may fall below 0
℃
or rise
above 40
℃
,
or in humidity higher than 93%. These
conditions will reduce battery life or cause a fault alarm.
5:Inextremely dusty, dirty, or insect – infested areas influence
particles interfere with smoke alarm device operation.
Operation:
Testing
Power on the alarm is mounted on bracket. Test the unit to
ensure proper operation by pressing the test button, this will
sound the alarm if the electronic circuitry, Bracket is
mounted, horn, and battery are working. If no alarm sounds,
there is a defective battery or other failure, you can refer to
“Trouble shooting” section for solution.
DO NOT
use an open flame to test your alarm, you could
damage the alarm or ignite combustible materials and start a
fire.
CAUTION:
Due to the loudness(85 decibels) of the alarm,
Always stand an arms-length away from the unit when
testing.
Test the alarm weekly to ensure proper operation. Erratic or