Document NO.:RD-517-39-001 

 

   

Version: B    2017.02.14 

- 7 - 

Wire on alarm harness connected to: 

 

Black wire --- Hot wire of AC line   

 

White wire --- Neutral wire of AC line 

 

Yellow  wire  ---  I/O  signal  as  interconnect  line  of  other       

Units in the multiple station set up.   

Mounting Instructions: 

 

After selecting the proper location for your smoke alarm, 

wire the AC QUICK CONNECTOR harness as described 

in the Wiring instructions (AC power should be turned off 

at this stage).

 

 

Turn  the  alarm  body  counterclockwise  and  seperate  the 

bracket.

 

 

Remove  locking  plug  from  the  bracket  with  screw  driver 

(refer to Diagram 9).   

 

 

 

 

 

 

 

 

 

 

Hold  the  bracket  in  the  installation  position,  mark 

installation holes of the bracket with a pencil.   

 

Bore two installation holes in the marked positions with a 

3/16  (5  mm)  drill  bit.    Press  the  two  plastic  plugs  into 

holes with hammer. (Refer to Diagram 10) 

 

 

Diagram 10 

 

Pull  the  AC  QUICK  CONNECTOR  through  the  center 

hole in the bracket. Attach the bracket to the plastic plugs 

and  tighten  the  screws  into  the  plastic  plugs  (refer  to 

Diagram 11 - installation sketch map).   

Installation sketch map: 

 

Diagram 11 

 

Install the battery into battery box. 

 

Connect  the  AC  QUICK  CONNECTOR  to  the  alarm 

body. 

 

Fit  the  alarm  on  the  bracket  and  turn  the  alarm  body 

clockwise, until it aligns with the bracket. 

 

Insert  locking  plug  into  the  gap  between  bracket  and 

bottom cover to lock the alarm in place (Refer to Diagram 

12). 

locking plug 

Diagram 9 

Do not tear labeling 

Holes of ceiling 

 

Plastic plugs 

 

Terminal

 

Bracket

 

Screws

 

AC quick connector

 

Содержание GS517

Страница 1: ...he basement ceiling at the bottom of the stairwell Typical multi storey dwelling installation recommendations Install a minimum of one smoke alarm on each occupiable level of the home Install a smoke alarm on the ceiling or wall inside each bedroom and in the hallway outside each separate sleeping area If a bedroom area hallway is more than 30 feet long install a smoke alarm at each end install a ...

Страница 2: ...adequate insure to protect their lives and property In addition it is possible for the smoke alarm to fail at any time For this reason you must test the smoke alarm weekly and replace them every 10 years Battery Specification Voltage DC 9V Carbon Zinc battery Gold Peak 1604P Replace Battery 1 Replace the battery Remove the locking plug between bracket and bottom cover See Diagram 1 Diagram 1 Remov...

Страница 3: ... your alarm may indicate a defective alarm NOTE WEEKLY TESTING IS REQUIRED LED indicators Illumination of the Green LED indicates that the alarm is receiving AC power This alarm is equipped with a red LED indicator with two modes of operation Red LED Flashing every 32 seconds indicates that the smoke alarm is operating properly RED LED Flashing when the Test button is pressed or the smoke alarm se...

Страница 4: ...he AC QUICK CONNECTOR is properly connect to the smoke alarm 2 If the problem still exists please return to your retailer 3 If the unit is out of warranty please replace another new alarm Smoke alarm does not sound when tested NOTE Push test button for at least five seconds while testing 1 Ensure that the battery and the AC QUICK CONNECTOR are properly connected 2 Clean smoke alarm 3 If there are ...

Страница 5: ... there 6 Call the fire department from your neighbor s home not from yours 7 Don t return to your home until the fire officials say that it is all right to do so 8 There are situations where a smoke alarm may not be effective to protect against fire as stated in the National Fire Alarm and Signaling Code NFPA 72 For instance a Smoking in bed b Leaving children home alone c Cleaning with flammable ...

Страница 6: ...nimum protection install at least one alarm close to the bedrooms For additional protection see SINGLE FLOOR PLAN and MULTIPLE FLOOR PLAN in Diagram 7 Diagram 7 WARNING TEST YOUR SMOKE ALARM OPERATION AFTER MOBILE HOME HAS BEEN IN STORAGE BEFORE EACH TRIPAND AT LEAST ONCE A WEEK DURING USE Wiring Instructions The appropriate power source is 120 volt AC single phase When installing or removing the ...

Страница 7: ...holes of the bracket with a pencil Bore two installation holes in the marked positions with a 3 16 5 mm drill bit Press the two plastic plugs into holes with hammer Refer to Diagram 10 Diagram 10 Pull the AC QUICK CONNECTOR through the center hole in the bracket Attach the bracket to the plastic plugs and tighten the screws into the plastic plugs refer to Diagram 11 installation sketch map Install...

Страница 8: ... use and service for a period of 3 years from the date of purchase This warranty does not cover damage resulting from accident misuse or abuse or lack of reasonable care of the product In no case shall company be liable for any incidental or consequential damages for breach of this or any other warranty express or implied whatsoever The defective product can be mailed to the following address with...

Отзывы: