Document NO.:RD-517-39-001
Version: B 2017.02.14
- 2 -
detects smoke.
7.
Smoke alarm may not alert every household member
every time. The alarm horn is loud in order to alert
individuals to a potential danger. However, there may be
some circumstances where a household member may not
hear the alarm (i.e. outdoor or indoor noise, sound
sleepers, drug or alcohol usage, the hard of hearing, etc.).
If you suspect that this smoke alarm may not alert a
household member, install and maintain specialty smoke
alarms. Household member must hear the alarm’s
warning sound and quickly respond to it to reduce the risk
of injury, or death that may result from fire, if a household
member is hard of hearing, install special smoke alarms
with lights or vibrating devices to alert occupants.
8.
Smoke alarms can only sound their alarms when they
detect smoke or detect combustion particles in the air.
They do not sense heat, flame, or gas. This smoke alarm
is designed to give audible warning of a developing fire.
However, many fires are fast - burning, explosive, or
intentional, and others are caused by carelessness or
safety hazards. In such circumstances, Smoke may not
reach the alarm
QUICKLY ENOUGH
to ensure safe
escape. Therefore the installation of smoke alarms is not a
substitute for practicing fire safety in the home.
9.
Smoke alarms have limitations. This smoke alarm is not
foolproof and is not warranted to protect lives or property
from fire. Smoke alarms are not a substitute for insurance.
Homeowners and renters should have adequate insure to
protect their lives and property. In addition, it is possible
for the smoke alarm to fail at any time. For this reason,
you must test the smoke alarm weekly and replace them
every 10 years.
Battery Specification:
Voltage: DC 9V (Carbon Zinc battery)
Gold Peak: 1604P
Replace Battery:
1: Replace the battery:
①
Remove the locking plug between bracket and bottom
cover. (See Diagram 1)
Diagram 1
②
Remove the alarm body from the bracket.
③
Squeeze the locking arms on the sides of the AC Quick
connector while pulling the connector away from the
bottom of the alarm.
④
After alarm has been removed, you can open the battery
cover and replace with new battery. (See Diagram 2)
Diagram 2
Warning: AC power should be turned off at this stage.
2: After you replaced the battery:
①
Close the battery cover,
②
Plug the AC QUICK CONNECTOR into the back of the
alarm, making sure that the locks on the connector snap
into place.
③
Fit the alarm body on bracket and turn the alarm body
clockwise (See Diagram 3).
Diagram 3
④
Insert locking plug into the gap between bracket and
bottom cover (See Diagram 4).
Diagram 4
3: Turn on the AC power, in the meantime, the green LED
lights up. Then test smoke alarm using test button, the
sound pattern is 3 short beeps-pause 1.5 seconds, cycle
this pattern continues until release the test button.
Then unit will goes into hush mode of 8 minutes. During this
period, the RED LED will flash once every 8 seconds. It will
go to normal operation status and flash once every 32
seconds after 8 minutes. Test the smoke alarm by pushing the
test button, if the alarm signal does not sound, this is an
indication that the smoke alarm is faulty or improperly
installed. Refer to the “trouble shooting” section for help.