![Sita IT Series Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/sita/it-series/it-series_manual-of-installation-use-and-servicing_1285532007.webp)
6
3.
Permissible operating range (data) according to ÖNORM M5873-1:2001
Permissible range of operation is the result of typetest according to ÖNORM M5873-1:2001.
For each UV-transmittance (%) is reported the minimum reference irradiance (W/m
2
) and the
maximum flow (m
3
/h) considering that the minimum Reduction Equivalent Fluence demanded is 400
J/m
2
.
UV 80 IT
UV-trasmittance
%T100 (100mm)
UV-trasmittance
%T10 (10mm)
Minimum reference
irradiance Emin
Maximum flow
Qmax
%
%
W/m2
m3/h
< 9
< 78,6
not permitted
0,00
9
78,6
97,14
14,59
10
79,4
100,48
15,90
11
80,2
103,54
17,14
12
80,9
106,36
18,32
13
81,5
108,98
19,45
14
82,2
111,44
20,53
15
82,7
113,76
21,57
16
83,3
115,95
22,57
17
83,8
118,04
23,55
18
84,2
120,03
24,50
19
84,7
121,95
25,43
20
85,1
123,80
26,35
21
85,6
125,60
27,24
22
85,9
127,34
28,13
23
86,3
129,04
29,00
24
86,7
130,70
29,87
25
87,1
132,33
30,73
26
87,4
133,93
31,59
27
87,7
135,51
32,45
28
88,0
137,07
33,31
29
88,4
138,62
34,16
30
88,7
140,15
35,02
31
88,9
141,67
35,89
32
89,2
143,18
36,75
33
89,5
144,68
37,63
34
89,8
146,18
38,51
35
90,0
147,68
39,39
36
90,3
149,17
40,29
37
90,5
150,67
41,19
38
90,8
152,16
42,10
39
91,0
153,65
43,03
40
91,2
155,15
43,96
41
91,5
156,64
44,90
42
91,7
158,14
45,86
43
91,9
159,65
46,82
44
92,1
161,16
47,80
45
92,3
162,67
48,79
46
92,5
164,18
49,79
Содержание IT Series
Страница 10: ...9 4 1 Installation scheme recommended ...
Страница 11: ...10 ...
Страница 12: ...11 ...