Remote OFF delay:
It allows to set the shutdown delay from remote contact. This setting can
helps when the remote ON/OFF contact is directly connected to a flow switch. By increasing
the remote off delay the system does not shut off for short flow stop.
Important!
The remote off delay cannot be too long otherwise the chamber may reach over temperature.
Module 4: G. alarm
➢
Contact NC/NO:
It allows to set the General Alarm contact.
NO
(factory settings) = it allow to set UV system General Alarm in normal
open condition (see electrical diagram).
NC
= it allow to set UV system General Alarm in normal close condition
(see electrical diagram).
➢
Contact GA/EV:
It allows to set the general alarm contact status in case of shutdown from the
user.
GA
(factory settings) = In this case water flow does not stop if an electrovalve
is driven by the General Alarm Contact
EV
= In this case water flow stops if an electro valve is driven by the General
Alarm Contact.