Siruba DL720 Скачать руководство пользователя страница 5

- 4 - 

 

 
 
5 Port Outline Diagram:   
5.1 Port Description 

 

If there are still errors, please replace the control box and call 
for customer service. 

E09 
E11 

Positioning signal error 

Turn off the machine, please check if the encoder in bad 
connection or is too loose. To get it right and turn on. If there 
are still errors, please replace the control box and call 
for customer service. 

E14 

Encoder signal error. 

Turn off the system power supply, please check motor encoder 
connector if loose or fall off, renew to normal then restart 
system. If still not work, please replace the motor and notify the 
manufacture.  

E15 

Power module abnormal over current 
protection 

Turn off the system power supply, and then restart the 
machine. If still not work, please replace the control box and 
notify the manufacture. 

E17 

The sewing table safety switch is not in 
the correct position 

Turn off the system power supply, please check machine head 
is open or not, the machine head switch is damage or not.   

Отзывы: