Siruba DL720 Скачать руководство пользователя страница 3

- 2 - 

 

1 Key Description 
 

 

 

Name Key 

Indicate 

Function 
Parameter Edit 

 

Press this key to enter or exit function parameter edit mode. 

Setting 
Parameter 
Check and 
Save 

 

For the content of the selected parameters check and save: after select parameter 
press this key to check and modify operation, after modified parameter value press 
this key to exit and save the parameter. 

On the 
Adjustment 
Key 

 

1. Choose the region parameter items of incrementing key 
2. Parameter setting value incrementing key 

Under the 
Adjustment 
Key 

 

1. Choose the region parameter items of diminishing key 
2. Parameter setting value decrementing key 

Slow Launch 
Setting 

 

If click, set used or cancelled slow launch function. 

Needle Stop 
Position 
Selection 

 

If click, the needle stop position after shift the sewing mode ( Up position / Down 
position) 

 
2. Operating Instructions 
2.1 Restore Factory Setting 

Under the shutdown state, hold on the “up” key and “down” key to boot, then double-click the S key to 

confirm it, shutdown restart. 

 

3 Parameter List 
 

Parameters Parameter 

Function Range Default 

Description 

P01 Maximum 

speed 

200-3700 3700 

Set the max sewing speed. 

P02 

Needle stop position 

selection 

0-2 1 

0: Needle up 1: Needle down 2: OFF 

P03 

Soft start switch 

0-1 1 

0: OFF 
1: ON 

P04 

Soft start sewing speed 

200-1500 400 

 

P05 

Stitches number of soft 

start 

1-15 1 

 

P06 Minimum 

speed 

200-500 200 

Set the minimum speed. 