4.
畫面顯示
E01
表示安全開關被觸動,無法回復。
5.
畫面顯示
E02
表示控制面板上的
EEPROM
異常,無法正
常動作。
排除方式:更換新的控制板(
FD683
)
6.
畫面顯示
E
表示圈數檢知器異常,無法正常動作
4.The panel displays E01
It indicates that the safety lock switch is
touched and cannot be reverted.
5.The panel displays E02
It indicates that EEPROM on the control
panel is abnormal,
and cannot work regularly.
Solution: Substitute another new control
panel (FD683).
6.The panel displays E03
It indicates that the coil detector is abnormal
and cannot work regularly.
P28
Introduction
Содержание 700KS-LFD6-K
Страница 1: ...700KS LFD6 K ORIGINAL INSTRUCTIONS BOOK PARTS LIST...
Страница 2: ......
Страница 12: ...COMBINATION 1 Contrl Box 1 2 Contrl Box 2 3 Contrl Box 3 Pedal Switch P9...
Страница 14: ...P Airsupplysource WIRING DIAGRAM P11...
Страница 29: ...1 2 1 The control panel is blank 2 The stepping motor driver is no signal P26 Introduction...
Страница 30: ...3 3 The setting value of the stepping motor driver P27...
Страница 32: ...7 E04 7 The panel displays E04 It indicates that the coil detector is abnormal and cannot work regularly P29...
Страница 34: ...P31...
Страница 35: ...P32...
Страница 36: ...P33 P33...
Страница 37: ...P34...
Страница 38: ...P35 P35...
Страница 39: ...P36 P36...
Страница 40: ...P37...
Страница 41: ...2017 02 06 P38 P38...
Страница 42: ...2017 02 06 2 P39 P39...
Страница 43: ...2017 02 06 1 P40 P40...
Страница 44: ...P41 P41...
Страница 45: ...P42 P42...