USER’S SECTION

FUEL EFFECT

This fire in certain models is supplied with ceramic
fuel  effect  pieces  to  simulate  a  real  fire  and  a
granular  bed  to  provide  flame  distribution  across
the bed. These items are safe to handle and they
are designed for easy re-fitting after removal

.

Gas consumption

Please refer to the general data on page 6 item 1

OPERATING INSTRUCTIONS -
  Manual Version

    Figure 1

                                                              OFF

IGNITION

HIGH

LOW

For  your  safety,  the  fire  is  fitted  with  a  Flame
Supervision  Device  (FSD),  which  will  shut  off  the
gas  supply  if  for  any  reason  the  pilot  is
extinguished.  This  device  incorporates  a  fixed
probe,  which  senses  heat  from  the  pilot  burner
flame. If the probe is cool, the device will prevent
any gas flow unless the control knob is pushed in
at the IGNITION position.

If for any reason the flames go out or if the fire has
been turned off for any reason, always WAIT FOR
3 MINUTES before attempting to relight.

TO LIGHT THE FIRE

1.

From  the  off  position,  SLOWLY  push  in
and turn the control knob anti-clockwise to
activate  the  spark  at  the  IGNITION
position.

2.

Keep  the  control  knob  pressed  in  at  this
position  for  approximately  10  –  20
seconds  to  allow  the  Flame  Supervision
Device to warm.

3.

Release the control knob. The pilot should
remain lit independently.

SELECT THE BURNER FLAME LEVEL

NOTE: When first turned on the flames will appear
predominately blue. The ceramic bed will take time
to warm up.

1.

After lighting the pilot as described above,
turn the control knob anti-clockwise to the
HIGH position. The fire will now ignite.

2.

To decrease the amount of flame push the
control  knob  in  slightly  and  turn  to  the
LOW position. The fire can now be used at
any  desired  setting  at  any  position
between  minimum  (LOW)  and  maximum
(HIGH).

TO TURN OFF

1.

Push  in  and  turn  the  control  knob
clockwise  to  the  OFF  position  to
extinguish the flames and the pilot flame.

2.

If  desired  he  pilot  flame  can  be  left  on  to
make it quicker and easier to light the fire.
Although the pilot is using gas all the time
it is on, the amount used is minimal. To do
this turn the control knob to the IGNITION
position  instead  of  the  OFF  position  as
described  above.  If  the  fire  is  to  be
switched  OFF  for  long  periods,  it  is
recommended  that  the  control  knob  be
turned to the OFF position.

CLEANING

All cleaning 

MUST

 be carried out when the fire is

cold.  NOTE:  Heat  is  retained  for  some  time  after
the  fire  is  switched  OFF.  Clean  the  surround  and
fender  parts  with  a  slightly  damp  cloth  and  then
dry. Abrasive cleaners should NOT be used.

Normally  the  fire  should  only  need  dusting.  Light
coatings of soot will usually be burnt off during the
normal operation of the fire. If however, particles of
mortar from the chimney accumulate these should
be  removed  from  the  coals  and  back  brick  by
dismantling them and cleaning with a soft brush

If  soot  or  other  foreign  matter  has  become  mixed
with the granular materials and cannot be removed
by  hand,  remove  the  contaminated  layer  and
replace  with  a  clean  layer.  When  levelling  ensure
that none of the granules are pushed into the pilot
burner outlet.

If large pieces of debris are found any where in the
fireplace,  the  chimney  and  appliance  should  be

V-11-07

Содержание Fire Royal 1000

Страница 1: ...E MANUAL REMOTE PLEASE KEEP THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE Our policy is constant development and improvement Strict accuracy of illustrations and specifications is not guaranteed Modifications to design and materials may be necessary subsequent to publication WINTHER BROWNE 75 Bilton Way Enfield London EN3 7ER Tel 0845 612 1893 Fax 0845 612 1894 V 11 07 eco ...

Страница 2: ...______________ 5 FUEL BED ASSEMBLY _________________________________________ 5 INSTALLATION SECTION ______________________________________ 6 1 GENERAL DATA__________________________________________ 6 2 GENERAL INSTALLATION REQUIREMENTS ___________________ 6 3 CHECK CARTON CONTENTS _______________________________ 7 4 THE FIREPLACE _________________________________________ 7 5 GAS SUPPLY PIPE_______...

Страница 3: ... 150mm DEEP MADE FROM WOOD OR ANY OTHER COMBUSTIBLE MATERIAL IS 766mm FOR COMBUSTIBLE PROJECTIONS ABOVE 150mm DEPTH ADD 12 5mm TO THE ABOVE CLEARANCE FOR EVERY 25mm OF ADDITIONAL PROJECTION DEPTH 9 NEVER THROW PAPER OR OTHER MATERIAL ONTO THE FIRE 10 IT SHOULD BE APPRECIATED THAT ALTHOUGH THIS APPLIANCE CONFORMS TO ALL THE REQUIRED STANDARDS IT IS A DECORATIVE FUEL EFFECT HEATING APPLIANCE WITH AN...

Страница 4: ...ise to the HIGH position The fire will now ignite 2 To decrease the amount of flame push the control knob in slightly and turn to the LOW position The fire can now be used at any desired setting at any position between minimum LOW and maximum HIGH TO TURN OFF 1 Push in and turn the control knob clockwise to the OFF position to extinguish the flames and the pilot flame 2 If desired he pilot flame c...

Страница 5: ...and follow the operating instructions on pages 4 and 5 The ODS is designed to shut off the gas supply to the burner if the oxygen content of the room falls below a certain level If it continues to operate then contact your installer to have the fire and flue system checked SERVICING AND MAINTENANCE If your fire requires servicing or maintenance please contact your supplier quoting the model name a...

Страница 6: ...ent person and installed in accordance with the current edition of I S 813 Domestic Gas Installations and the current building regulations 2 2 The appliance can be used in the following openings A Fireplace recess built from components according to BS 1251 Open Fireplace Components The flue should be a class 1 type with a minimum effective height of 3 meters The Minimum depth of the opening 310mm ...

Страница 7: ...locality note the spillage test requirements detailed on page 16 2 14 VENTILATION REQUIREMENTS For use in GB purpose built ventilation is not normally required for 600 model The 1000 model REQUIRES ventilation of min air space 100mm x 100 mm For use in I E ventilation must be in accordance with IS 813 2 15 It is essential that all decorative fenders have a minimum open area of 50cm_ to ensure adeq...

Страница 8: ...pply and check for gas soundness with a suitable leak detection fluid see BS 6891 Please check all joints including the pilot assembly 6 6 FUEL BED ASSEMBLY Refer to the User s section for details 7 FUNCTIONAL CHECKS Remove the pressure test point sealing screw from the isolation elbow and attach a suitable pressure gauge Light the pilot and check the correct operation of the burner at all the fla...

Страница 9: ...ace for replenishment 9 5 Please explain to the customer the purpose of the Oxygen Depletion System ODS and in particular the following a The ODS system operates if the Oxygen level in the room falls below safe levels usually due to interruption of the evacuation of combustion products i e a blocked chimney etc b Describe the restart procedures c Point out that on operation of the ODS system they ...

Страница 10: ...the 8mm burner supply tube from the tap e Disconnect the 8mm gas inlet tube from the tap f Pull off the control knob g Remove the retaining nut from the front of the control panel The tap FSD ignition unit can now be removed and exchanged h Re assemble in the reverse order 11 MAINTENANCE SPARES During servicing and maintenance your appliance may need some replacement parts Here is a short list of ...

Страница 11: ...unt of granular material in the burner tray See section 6 6 3 Try slight adjustments to the fuel effect pieces IGNITION FUNCTIONAL CHECK 1 NO See NO SPARK chart NO Consult the User s section in this manual and retry NO Check isolation tap and gas meter and retry NO Correct and retry NO Ther is a blockage in the system Check the inlet test point the mag valve seating and blow out any dirt from the ...

Страница 12: ...assembly e g coal soot etc Check for fluff in the pilot aeration hole See figure 19 PILOT WILL NOT STAY LIT OR FIRE GOES OUT If the appliance goes out in use continually this may mean that the oxygen depletion sensor ODS has been activated The appliance should not be used until the cause has been found and rectified IGNITION FUNCTIONAL CHECK 2 NO Consult the User s section in this manual and retry...

Страница 13: ...13 FIG 6 SCREWS SUPPLIED FLUE ADAPTER OPTION NOT INCLUDED GATHER HOOD CANOPY SCREWS SUPPLIED V 11 07 ...

Отзывы: