14
4B Use of the machine
4.1 - Control Panel Legend
1. ON-OFF
- Turning the machine on and off:
briefly pressthe ON button
pressthe OFF button for 3 sec.
- Interruption of work phase:
During the work phases, if pressed, it stops the processing and passes to the next one.
- Vac Time or Seal Time Selection:
when in the ON mode, if pressed,it allows you to move the arrow in order to select
Between VacTime and Seal Time (for their modification use keys 2 and 3 to
increase or decreasetheirvalues)
Note: the software always saves the latest change.
2. Increase the Selected Values
- Press to increase the values previously selected:
Adjustable values: vacuum packing time; seal time or external vacuumpacking time
- When in the OFF mode, if pressed for 3 times in a row,the pre-heating cycle or
expulsion of water residues from the oil pump will be started
To be performed after vacuum cycles with liquid products, or every 15 days.
The duration of the cycle is 15 minutes and can be interrupted by pressing the 1 button
NB This should be always performed with the suction cap closed (turn the
cap to close the slots)
3. Decrease the Selected Values
- Press to decrease the values previously selected:
Adjustable values: vacuum packing time; sealing time or external vacuum packingtime
Pressing buttons 2 and 3 simultaneously switching from vacuumpacking cavity
mode to external vacuum packing mode in a cyclic modality.
4. Analog Display
- It allows the working modalities to be viewed:
OFF
cavity vacuum packing
external vacuum packing
pre-heating or expulsion of water residuals
Vacuum percentage
1
4
3
2
Fig. 4.1.1
7
E
ngl
is
h
The Manufacturer is not deemed liable for the consequences caused by the
user’s failure to comply with the safety precautions given in this manual.
1.5 - Description of the machine
The vacuum packaging machine with dome is controlled electrically and therefore
not subject to wear. The electronically-governed sealing system, is composed of a
flat resistance (5mm) bakelite bar which, thanks to an excellent pneumatic system
installed, guarantees balanced and even sealing on any type of bag to be used
(nylon, polyethylene, Cryovac).
The vacuum pumps used are very modern and guarantee surprising silence even
though operating with uninterrupted cycles along with a very high level of final
vacuum.
The models represented in this manual have been created in compliance with the
2006/42 EEC Directive
and successive amendments.
In the event of an accident, the manufacturer cannot be held responsible if the
machine has been modified, tampered with, the safety protections have been
removed or used in ways not declared by the manufacturer.
1.6 - Declared use
The machine has been designed and manufactured to vacuum pack products
according to the instructions in this manual and must be intended for this use only.
Any other use must be considered improper and therefore dangerous. The
Manufacturer cannot be considered responsible for any damage deriving from
improper, incorrect or unreasonable use.
It must be used in professional environments and any staff using the machine must
have experience in the sector and have read and understood this manual.
1.7– Uses not allowed
1.7.1 - Safety prescriptions
The following points must be respected:
1 never touch the metal parts of the machine with wet or damp hands;
2 do not pull the power supply cable or the appliance itself, to disconnect the plug
from the current;
3 do not allow the packaging machine to be used by children or untrained staff;.
4 the electric safety of this machine is only assured when the same is correctly
connected to an efficient earth plant, as envisioned by the electric Safety
Standards in force; this fundamental requirement must be verified. If in doubt,
request an accurate control of the system by professionally qualified staff; the
Manufacturer cannot be considered responsible for any damage caused by
the failure to earth the system;
5 in the event of possible damage to the earth protection, the machine must be put
out of service, in order to prevent undesired and/or involuntary activation;