BEFORE YOU INSTALL
Sirius warranty covers only Sirius product. If you choose to install a non-Sirius branded accessory such as
flexible ducting, Sirius will only warrant the hood and motor. If installation or inferior parts are found to be the
cause of failure or issue then charges will apply for service and parts.
Flexible ducting is not permitted under any circumstances. Flexible ducting has been found to increase noise
levels, increase vibration and reduce airflow. Sirius Semi-rigid or solid ducting can be used in lieu. There is a
range available to suit any application.
Available at www.siriusbrand.com
A reduction in the duct diameter from stated ducting size will void warranty.
If you are in doubt about the ducting, please contact Sirius on 1300 762 219 prior to
installation.
Before proceeding with the installation of the ceiling cassette, please thoroughly inspect the entire unit
(including the motor) for any damages, including all of the electrical connections. If any damage is found,cease
installation and report it immediately to the retail partner that the cassette was purchased from.
Reduction of the ducting diameter will void the manufacturer warranty as it will severely affect the performance
of the motor and may cause damage with prolonged usage.
Use ducting approved by standards enforced, see www.siriusbrand.com for details for approved ducting. The
manufacturer will not be deemed responsible for air capacity and noise problems caused by failure to comply
with the above and no warranty on the product will be provided.
FAILURE TO INSTALL THE SCREWS OR FIXING DEVICE IN
ACCORDANCE WITH THESE INSTRUCTIONS MAY RESULT IN
ELECTRICAL HAZARDS OR ELECTROCUTION.
The cassette requires one 10AMP GPO located inside the ceiling cavity
to power both the lighting and the motor.
• Only use Sirius Ducting with a maximum length of 7 metres & minimum of 2 metres from the outlet collar
on the cassette to the motor location.
• Limit the number of elbows in the ducting, since each 90 degree bend reduces the air capacity by 1 lineal
metre (e.g. if there are 2 x 90 degree bends, the maximum duct length should not exceed 5 metres.)
• Avoid abrupt changes of direction where possible, bends of more than 90 degrees should be avoided at all
costs.
• A minimum of 150mm ducting is applicable to the SLT977EMEL and SLT978EMEL.