background image

2

3

The symbol on the product or on its packaging indicates that this product 
may not be treated as house-hold waste. Instead it shall be handed 
over to the applicable collection point for the recycling of electrical and 
electronic equipment. By ensuring this product is disposed of correctly, 
you will help prevent potential negative consequences for the environment 
and human health, which could otherwise be caused by inappropriate 
waste handling of this product. For more detailed information about 
recycling of this product, please contact your local city office, your 
household waste disposal service or the shop where you purchased the 
product. This appliance is marked according to the European directive 
2002/96/EC on waste electrical and electronic equipment (WEEE).

Min. 600mm - Max. 700mm 

for electric cooktops.

Min. 650mm - Max. 750mm

 gas cooktops.

If the rangehood is positioned above the max height 
recommended, warranty may be compromised 
as performance of the rangehood will be affected.
Measurement is taken from the top of the trivets to 
the underside of the hood. (Fig.1)

•  The air being drawn can’t be conveyed through 

or into a duct used to let out fumes from 
appliances fed by energy other than electric 
power (eg. centralized heating, radiators, water 
heaters, etc.).

•  Attention: remove any possible PVC film from the 

stainless steel, including the filters.

•  To externally vent, please comply with the 

pertaining rules given by competent authorities.

•  Provide the room with an adequate ventilation 

when a rangehood and appliances fed by energy 
other than electric power (gas, oil, or coal stoves, 
etc.) are used simultaneously. The rangehood, 
when evacuating the air, could generate a 
negative pressure in the room which can’t exceed 
the limit of 0.04 mbar, in order to avoid the 
suck of exhausts deriving from the heat source. 
Therefore the room should be provided with air 
intakes to allow a constant flow of fresh air.

If the rating label in the rangehood shows the symbol       
    , the appliance is built in class II° and it 

does not 

need

 any earth connection.

If the rating label in the rangehood does not show 
the symbol     , the appliance is built in class I° and it 

needs

 the earth connection.

When performing the electrical connections on the 
appliance, please make sure that the current-tap 
is provided with earth connection and that voltage 
values correspond to those indicated on the label 
placed inside the appliance itself. 

Before carrying out any cleaning or maintaining 
operations, the appliance needs to be switched off. 
If the appliance is not provided with a non-separable 

When ducting rangehood, options are as follows:

Roof vent - EASYROOF 150T/M 

 

        

EASYROOF 200T/M

*Kit includes roof flashing

Download installation guide

Eave vent - EASYEAVE 150/200

Download installation guide

Wall vent - EASYWALL 150/200

Download installation guide

BEFORE YOU INSTALL – please read

Sirius warranty covers only Sirius product. If you choose to install a non-Sirius branded 

accessory such as flexible ducting, Sirius will only warrant the hood and motor. If installation 

is found to be the cause of failure or issue then charges will apply for service and parts. 

Flexible ducting is not permitted under any circumstances. Flexible ducting has been found to 

increase noise levels, increase vibration and reduce airflow. 

Sirius Semi-rigid or solid ducting can be used in lieu.  

There is a range available to suit any application.

Ducting available at www.siriusbrand.com

A reduction in the duct diameter from stated ducting size will void warranty.

If you are in doubt about the ducting, please contact Sirius on 1300 762 219 prior to installation

flexible cable and plug, or with another device 
ensuring omnipolar disconnections from the grid, 
with an opening distance between the contacts of at 
least 3mm, then such disconnecting devices must be 
supplied within the fixed installation.
If the fixed appliance is endowed with a supply cord 
and a plug, the appliance has to be put in a place 
where the plug can be reached easily.

The use of materials which can burst into flames 
should be avoided in close proximity of the appliance. 
When frying, please pay particular attention to fire 
risk due to oil grease. Being highly flammable, fried 
oil is especially dangerous. Do not use uncovered 
electric grills. In order to avoid possible fire risk, all 
instructions for grease-filter cleaning and for removing 
eventual grease deposits should be strictly followed.

WARNING

600 - 700mm (electric)

650 - 750mm (gas)

600 - 700mm (electric)

650 - 750mm (gas)

CAUTION

(Fig. 1)

(Fig. 2a)

(Fig. 2b)

(Fig. 2c)

Dome 
featured on 
200mm kit 
only

SIDE VIEW

FRONT VIEW

WARNING

The appliance must be installed and 

connected to the power supply only by a 

qualified technician.

•  There shall be adequate ventilation of the room when the range hood is used at the same time as 

appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the 
room)

•  The details concerning the method and frequency of cleaning
•  There is a fire risk if cleaning is not carried out in accordance with the instructions;
•  Do not flambé under the 

range hood

;

•  CAUTION: Accessible parts may become hot when used with cooking appliances.

Содержание 9351116000660

Страница 1: ...tulations on your purchase Thank you for choosing a Sirius product SLTC 97 900 EAN 9351116001612 SL22 900 EAN 9351116000660 SL7 1200 EAN 9351116000813 SL107 S900 EAN 9351116001728 SLTC 107 G900 EAN 9351116001735 SL107 S1200 EAN 9351116001742 www siriusbrand com ...

Страница 2: ...liance needs to be switched off If the appliance is not provided with a non separable When ducting rangehood options are as follows Roof vent EASYROOF 150T M EASYROOF 200T M Kit includes roof flashing Download installation guide Eave vent EASYEAVE 150 200 Download installation guide Wall vent EASYWALL 150 200 Download installation guide BEFORE YOU INSTALL please read Sirius warranty covers only Si...

Страница 3: ...outer line of the cover this will give you the exact location of where the top fixing bracket needs to be fitter to the ceiling 10 Fix the top fixing bracket into place using the supplied 30mm screws Fig 7 and telescope the upper flue cover over the bracket and secure in place with the very small 10mm supplied screws Fig 8 CANOPY RANGEHOOD INSTALLATION ONBOARD MOTOR Before installing the appliance...

Страница 4: ... may require cleaning sooner if frequent heavy frying is done To clean the appliance itself water and detergent are recommended while abrasive products should be avoided For steel appliances specialized detergents are recommended please follow the instructions indicated on the product itself to obtain the desired results MAINTENANCE Manual control buttons SL22 900 SL7 1200 SL107 S900 SL107 S1200 A...

Страница 5: ...8 9 SL22 900 WIRING DIAGRAM SLTC 97 900 WIRING DIAGRAM ...

Страница 6: ...10 11 SLTC 107 G900 WIRING DIAGRAM SL107 S900 WIRING DIAGRAM ...

Страница 7: ...12 13 BRACKET TEMPLATE SL 107 S1200 WIRING DIAGRAM ...

Страница 8: ... siriusbrand com All efforts have been made to ensure that the information provided in this brochure is correct at the time of printing Due to continuous product improvement and ongoing development Sirius reserves the right to make changes to the products and technical data without prior notice Some products appearing in this brochure may be for illustrative purposes only Diagrams are indicative m...

Отзывы: