background image

Ra

n

ge

 H

o

o

d

s

V

ented

ge.com

49-80438    08-06 JR   

Safety Information

 . . . . . . . . 2, 3

Operating/Care and 
Cleaning Instructions

Charcoal Filters  . . . . . . . . . . . . . .5
Grease Filters . . . . . . . . . . . . . . . .4
Hood Lights  . . . . . . . . . . . . . . . .5
Hood Surfaces  . . . . . . . . . . . . . . .5
Stainless Steel Surfaces  . . . . . . . .5
Vent Controls  . . . . . . . . . . . . . . .4

Installation Instructions

 . . .6–15

Troubleshooting Tips

 . . . . . . .16

Consumer Support

Consumer Support  . . . . . . . . . .20
Warranty  . . . . . . . . . . . . . . . . . . 19

JV535
JV536
JV565
JV566
JV635
JV636
JV665
JV666

Owner’s Manual

and Installation

Instructions

Write the model and serial 
numbers here:

Model #

________________

Serial # __________________

Find these numbers on a label
on the back wall of the hood.

Summary of Contents for JV666HSS

Page 1: ...ss Steel Surfaces 5 Vent Controls 4 Installation Instructions 6 15 Troubleshooting Tips 16 Consumer Support Consumer Support 20 Warranty 19 JV535 JV536 JV565 JV566 JV635 JV636 JV665 JV666 Owner s Manu...

Page 2: ...back to an exit Based on Kitchen Firesafety Tips published by NFPA WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE A Never leave surface units unattended at high settings Boilovers cause smokin...

Page 3: ...t le dos une sortie Bas sur l ouvrage intitul Kitchen Fire Safety Tips publi par la NFPA AVERTISSEMENT R DUISEZ LE RISQUE D UN FEU DE GRAISSE SUR LA SURFACE DE CUISSON DU FOUR A Ne laissez jamais sans...

Page 4: ...FAN OFF NITE HI LIGHT Reusable Metal Grease Filters The hood has 2 metal reusable grease filters The metal filters trap grease released by foods on the cooktop They also help prevent flaming foods on...

Page 5: ...r GE supplier If the model is not vented to the outside the air will be recirculated through disposable charcoal filters that help remove smoke and odors The charcoal filters should be replaced when t...

Page 6: ...exceed 65 equivalent feet NOTE It s important that ducting be installed using the most direct route and with as few elbows as possible This ensures clear venting of exhaust and helps prevent blockage...

Page 7: ...ry air movement the total duct length of a 31 4 x 10 rectangular 6 or 7 diameter round duct should not exceed 65 equivalent feet DUCTING CHART JV5 Series Models 0 25 50 75 100 125 150 175 Equivalent L...

Page 8: ...NGTH DUCT EQUIVALENT NUMBER PIECES LENGTH x USED TOTAL 6 Round 24 Ft x Ft wall cap 18 ft w o with damper x Ft damper 6 Round 33 Ft x Ft roof cap 6 Round 2 Ft x Ft to 31 4 x 10 rect transition 6 Round...

Page 9: ...If you are going to vent your range hood to the outside see the Ducting Requirements section for exhaust duct preparation 66 or more from the floor to the top of the hood 30 or 36 30 min Bottom edge...

Page 10: ...ne the vent option that your installation will require from the following choices The outside vent exhaust option that your installation requires will determine the hood knockouts that you will use NO...

Page 11: ...move the protective shipping film from the edges of the metal grease filters Press the filter locks back and lift the filters out Set them aside REMOVE WIRING COVER FROM THE JUNCTION BOX Remove the wi...

Page 12: ...RTICAL DUCTED DISCHARGE INSTALLATIONS ONLY Re install the 7 round exhaust adaptor with its screws removed in Step 2 under the Prepare the Hood section 6 7 8 7 round exhaust adaptor NOTE The 7 round ex...

Page 13: ...ss hole in wall Hood mounting screws 4 Horizontal duct access hole Cabinet bottom 1315 16 30 hood 1615 16 36 hood 17 16 1 8 33 4 51 4 51 4 127 16 1315 16 30 hood 1615 16 36 hood C Outside rear exhaust...

Page 14: ...the power on until installation is complete 12 11 13 SCREW IN PARTWAY Drive a mounting screw from the hardware packet partway into each center of the narrow neck of the keyhole slots marked on the ca...

Page 15: ...ust be permanently grounded Connect house wiring 120 VAC to hood wiring CONNECT WIRING Connect house black to hood black wire house white to hood white wire and house ground to hood green yellow wire...

Page 16: ...service Fan continually cycles The motor is probably Replace the filter if it is soiled If it is not soiled off and on overheating and turning itself or if replacing the filter does not solve the prob...

Page 17: ...Notes 17 Safety Instructions Operating Instructions Installation Instructions Troubleshooting Tips Consumer Support...

Page 18: ...18 Notes Consumer Support Troubleshooting Tips Installation Instructions Operating Instructions Safety Instructions...

Page 19: ...arranty excludes the cost of shipping or service calls to your home Some states do not allow the exclusion or limitation of incidental or consequential damages This warranty gives you specific legal r...

Page 20: ...at are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your w...

Page 21: ...ero inoxidable 4 Superficies de la campana 4 Instrucciones de instalaci n 5 14 Solucionar problemas 15 Soporte al consumidor Soporte al consumidor 20 Garant a 19 JV535 JV536 JV565 JV566 JV635 JV636 JV...

Page 22: ...mas con sus espaldas hacia una salida Basado en Ideas para la seguridad en la cocina publicado por NFPA ADVERTENCIA PARA REDUCIR EL RIESGO DE UN FUEGO DE GRASA DE ESTUFA A Nunca deje unidades de super...

Page 23: ...tes a los de su modelo Control del VENTILADOR Gire a LO bajo MED medio HI alto o MAX m ximo sea necesario El uso continuo del sistema de ventilaci n mientras cocina ayuda a mantener la cocina m s c mo...

Page 24: ...t n incluidos con la campana Deben ser ordenados de su suplidor GE Si el modelo no tiene ventilaci n hacia el exterior el aire se recircula a trav s de los filtros de carb n desechables que ayudan a e...

Page 25: ...7 de di metro no debe superar el equivalente a 65 pies NOTA Es importante que los ductos se instalen usando la ruta m s directa y con el menor n mero posible de codos Esto garantiza una ventilaci n di...

Page 26: ...a 65 pies Transici n rectangular de 31 4 x 10 a circular de 6 2 pies Codo de 90 circular de 7 14 pies Tapa de techo de 7 39 pies TABLA PARA LOS DUCTOS Modelos de la serie JV5 0 25 50 75 100 125 150 1...

Page 27: ...E DEL DUCTO PIEZAS LONGITUD N MERO DEL DUCTO EQUIV x USADO TOTAL Tapa de 24 pies x pies pared circ 18 pies sin de 6 con reg de tiro x pies reg de tiro Tapa de 33 pies x pies techo circ de 6 Transici n...

Page 28: ...uctos para la preparaci n del ducto del escape 66 o m s desde el piso hasta la parte superior de la campana 30 36 M n 30 El borde inferior del gabinete debe tener una distancia de 30 o m s desde la su...

Page 29: ...e entre las siguientes opciones la opci n de ventilaci n que su instalaci n requiere La opci n de escape de ventilaci n exterior que su instalaci n requiera determinar los agujeros ciegos de la campan...

Page 30: ...mpaque de los bordes de los filtros met licos para la grasa Presione los bloqueos del filtro y levante los filtros hacia afuera Col quelos a un lado RETIRE LA TAPA DEL CABLEADO DE LA CAJA DE EMPALME R...

Page 31: ...S DE SALIDA CIRCULAR CON DUCTO VERTICAL DE 7 NICAMENTE Vuelva a instalar el adaptador del escape de 7 con los tornillos correspondientes retirados en el paso 2 bajo la secci n Preparar la campana 6 7...

Page 32: ...16 1315 16 campana de 30 1615 16 campana de 36 C Escape posterior exterior ducto horizontal rectangular 31 4 x 10 Use el diagrama o la campana como una plantilla y marque la localizaci n en el gabinet...

Page 33: ...n est completa 12 11 13 ATORNILLE PARCIALMENTE Inserte un tornillo de montaje del paquete de herramientas parcialmente en cada centro del cuello angosto de las ranuras de bocallave marcadas en el fon...

Page 34: ...l cableado de la casa 120 VAC al cableado de la campana CONECTE EL CABLEADO Conecte el cable negro de la casa al cable negro de la campana el cable blanco de la casa al cable blanco de la campana y el...

Page 35: ...a solicitar servicio El ventilador est Probablemente el motor est Reemplace el filtro si est sucio Si no est sucio permanentemente sobrecalentado y se apaga solo o si reemplazar el filtro no solucion...

Page 36: ...16 Soporte al consumidor Solucionar problemas Instrucciones de instalaci n Operaci n Seguridad Notas...

Page 37: ...17 Seguridad Operaci n Instrucciones de instalaci n Solucionar problemas Soporte al consumidor Notas...

Page 38: ...18 Notas Soporte al consumidor Solucionar problemas Instrucciones de instalaci n Operaci n Seguridad...

Page 39: ...a garant a excluye el costo de env o o las visitas de servicio a su casa Algunos estados no permiten la exclusi n o las limitaciones de da os incidentales o consecuenciales Esta garant a da derechos l...

Page 40: ...garant a est a n activa Puede comprarla en l nea en cualquier momento o llamar al 800 626 2224 durante horas normales de oficina GE Consumer Home Services estar a n ah cuando su garant a termine Pieza...

Reviews: