Reader Equipment Installation
ID
entity
6204
User’s Guide
7
2.2.3.
Connecting the External Antenna
The ID
entity
6204 supports four external Tx/Rx antennas. Connect the
antenna to the antenna port located on the bottom of the reader.
Refer to Chapter 7 – Specifications for specific information regarding the
external antenna and antenna cable.
Caution:
The IDentity 6204 is equipped with four external RF ports. If activated, these RF
ports must be properly terminated with a 50 ohm load or a functional UHF
antenna before power up. Always power down the reader before removing an
antenna or load from an RF port.
ATTENTION
The IDentity 6204 antenna ports may be susceptible to damage from
static discharge or other high voltage. Use proper Electrostatic
Discharge (ESD) precautions to avoid static discharge when handling or
making connections to the IDentity 6204 reader antenna or
communication ports. Equipment failure can result if the antenna or
communication ports are subjected to ESD.
2.2.4.
Connecting Digital Inputs/Outputs
The ID
entity
6204 is equipped with a general purpose digital input/output
(I/O) port that provides four optically isolated 5-24 VDC input signals and
four open-collector output signals. The digital inputs can be used as general
purpose inputs or to trigger the reader for tag reading. These inputs can be
configured to provide an external read trigger from proximity sensors, photo
switches, or other devices.
The digital outputs can be used as general purpose outputs, to indicate tag
reading activity, or to indicate the reader is transmitting (RF On). The
outputs can also be configured to trigger conveyor gates or other access
control and sorting devices. For detailed information on configuring the
digital inputs and outputs refer to Chapter 7.
2.2.5.
Connecting the Power
The ID
entity
6204 operates on 24 Vdc provided through the bulkhead
connector on the rear of the reader. Connect the power supply to the reader
and connect the power supply to your 100–240 Vac, 50-60 Hz power
source. Allow 30 seconds for the reader to initialize.
Refer to the Chapter 8 –
Specifications
for details on the bulkhead
connector.