Step 1.
Select “
Advanced Network > linkCONNECT”
to enter the linkCONNECT settings.
Figure 16.
linkCONNECT settings
linkCONNECT Settings
Parameter
Instruction
Serial to TC/IP mode
Disable, Server and Client mode
Server IP/Port
IP address and domain name for Server IP
Socket Type
TCP/UDP protocol
Socket Timeout
Setting time to transmit data to serial port
Serial Timeout
Serial timeout is the waiting time for transmitting a
data packet. The default setting is 500ms.
Packet payload
Packet payload is the maximum transmission length
for serial port data packet. The default setting is
1024bytes.
Heart-beat Content
Send heart beat to the defined server to keep router
online. It is convenient to monitor the router from the
server.
Table 11.
linkCONNECT settings instruction