Power source and temperature ratings

Verify that the power source is appropriate before you plug in and operate the unit. Use the
unit under conditions where the temperature remains within the range given in the Technical
Specifications of this product. You can download the HD18 SA datasheet at www.siqura.com.

Optical safety

The following optical safety information applies to HD18 SA models with SFP interface. 

This product complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to
Laser Notice No. 50, dated June 24, 2007. This optical equipment may contain Class 1M lasers
or LEDs and has been designed and tested to meet IEC 60825-1:1993+A1+A2 and IEC
60825-2:2004 safety class 1M
 requirements.

Warning: Optical equipment presents potential hazards to testing and servicing personnel,
owing to high levels of optical radiation.

When using magnifying optical instruments, avoid looking directly into the output of an
operating transmitter or into the end of a fiber connected to an operating transmitter, or there
will be a risk of permanent eye damage. Precautions should be taken to prevent exposure to
optical radiation when the unit is removed from its enclosure or when the fiber is disconnected
from the unit. The optical radiation is invisible to the eye.

Use of controls or adjustments or procedures other than those specified herein may result in
hazardous radiation exposure.
 

The installer is responsible for ensuring that the label depicted below (background: yellow;
border and text: black) is present in the restricted locations where this equipment is installed.
 

EMC

This device has been tested and found to meet the CE regulations relating to EMC and
complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) This device must accept any
interference received, including interference that may cause undesired operation. These limits
are designed to provide reasonable protection against interference to radio communications in
any installation. The equipment generates, uses, and can radiate radio frequency energy;
improper use or special circumstances may cause interference to other equipment or a
performance decrease due to interference radiated by other equipment. In such cases, the
user will have to take appropriate measures to reduce such interactions between this and
other equipment.

Any interruption of the shielding inside or outside the equipment could make the equipment
more prone to fail EMC requirements.

Non-video signal lines must use appropriate shielded Cat 5 cabling (S-FTP), or at least an
equivalent. Ensure that all electrically connected components are carefully earthed and
protected against surges (high voltage transients caused by switching or lightning).

ESD

Electrostatic discharge (ESD) can damage or destroy electronic components. Proper
precautions should be taken against ESD when opening the equipment.

Safety and compliance

 6 

Содержание HD18 SA

Страница 1: ...HD18 SA 316L Analogue PTZ dome camera with D N and WDR Installation Manual...

Страница 2: ...pective owners Liability Siqura accepts no liability for claims from third parties arising from improper use other than that stated in this manual Although considerable care has been taken to ensure a...

Страница 3: ...y 7 3 Product overview 8 3 1 Features 8 3 2 Operation requirements 8 3 3 Package contents 9 3 4 Dimensions 9 4 Mount the camera 10 4 1 Use SA Wall Mount H 10 4 2 Use SA Sunshield H optional 12 5 Conne...

Страница 4: ...ct closure transmissions Before you start We advise you to read and observe all instructions and warnings in this manual before you continue Keep this manual with the original bill of sale for future...

Страница 5: ...ations accessible to trained service personnel only Safety requirements The equipment described in this manual has been designed and tested according to the UL IEC EN 60950 1 safety requirements For c...

Страница 6: ...diation exposure The installer is responsible for ensuring that the label depicted below background yellow border and text black is present in the restricted locations where this equipment is installe...

Страница 7: ...r be classified as reactive hazardous waste It is safe for normal disposal as required for batteries by your local authority 2 2 Cautions Handle the camera carefully Do not abuse the camera Avoid bump...

Страница 8: ...6x Optical zoom 12x Digital zoom Day Night with IR cut filter Wide Dynamic Range Backlight Compensation 316L Stainless steel construction 360 Continuous rotation 400 s Preset targeting 256 Presets 8 P...

Страница 9: ...t the box contains the items listed here If any item is missing or has defects do not install or operate the product Contact your supplier for assistance 316L Stainless steel housing with dome body in...

Страница 10: ...ng bracket for SA dome cameras SA Pole mount adapter H 316L Pole mounting adapter for SA wall mount H SA Sunshield H 316L Sunshield for SA dome cameras In This Chapter 4 1 Use SA Wall Mount H 10 4 2 U...

Страница 11: ...Mount the camera 11...

Страница 12: ...4 2 Use SA Sunshield H optional The following pictures show how to mount SA Sunshield H This accessory is supplied with bolts M8 4x nuts M8 4x and washers 4x Mount the camera 12...

Страница 13: ...Mount the camera 13...

Страница 14: ...ower cable The two cables are not included in the package contents of the camera but can be obtained from Siqura To connect and power the camera 1 Connect the video data cable to the ten pin video dat...

Страница 15: ...Connect the camera 15...

Страница 16: ...ction Instruction Set Preset Number key press and hold the Preset button for three seconds Go Preset Number key Preset to command a dome camera to go to a specific preset position Display or hide an O...

Страница 17: ...Cable definition D protocol keyboard to PTZ camera For the D protocol keyboard For the HD18 SA camera Use a control keyboard 17...

Страница 18: ...Connect the camera 14 D Dimensions 9 F Features 8 Functions 16 M Mount the camera 10 O Operation requirements 8 P Package contents 9 Product overview 8 S Safety and compliance 5 Safety information 5...

Отзывы: