SIP Medusa Ti-1002 Скачать руководство пользователя страница 2

31 

 

Declaration of Conformity 

 

We 

 

SIP (Industrial Products) Ltd 

Gelders Hall Road 

Shepshed 

Loughborough 

Leicestershire 

LE12 9NH 

England 

 

As the manufacturer's authorised representative within the EC 

declare that the 

 

Medusa Ti-1002 - SIP Pt. No. 03951 
Medusa Ti-2002 - SIP Pt. No. 03953 

 

Conforms to the requirements of the following directive(s), as indicated.

 

                       

              2006/95/EC                         Low Voltage Directive 

                                           98/37/EC                             Machinery Directive 
                                           2004/108/EC                       EMC Directive 
                                           97/68/EC                             Emissions From Non-road Mobile Machinery

 

                                           

As Amended By 

                                                                       2002/88/EC 
                                                                       2006/96/EC 

                                                                      

200/14/EC                           Noise Emission Directive 

                                           2002/95/EC                         ROHS Directive 

                                           

As Amended By 

                                                                       2005/618/EC, 2005/717/EC, 2005/747/EC, 2006/310/EC, 2006/690/EC, 2008/35/EC, 2008/385/EC 

And the following harmonised standard(s) 

 

EN 12601:2001 

EN 55012:2002+A1:2005 

EN 61000-6-3:2007 
EN 61000-6-1:2007 

Signed: …………………………………... 

Mr P. Ippaso - Director - SIP (Industrial Products) Ltd 
Date: 20/04/2010. 

  DECLARATION OF CONFORMITY 

Содержание Medusa Ti-1002

Страница 1: ...the local amenity tip and place into the appropriate recycling bin Never dispose of electrical equipment or batteries in with your domestic waste If your supplier offers a disposal facil ity please us...

Страница 2: ...d 2006 95 EC Low Voltage Directive 98 37 EC Machinery Directive 2004 108 EC EMC Directive 97 68 EC Emissions From Non road Mobile Machinery As Amended By 2002 88 EC 2006 96 EC 200 14 EC Noise Emission...

Страница 3: ...s 7 Guarantee 8 Technical Specifications 9 Getting To Know Your Generator 11 Operating Instructions 18 Maintenance 20 Exploded Drawing Ti 1002 21 Parts List Ti 1002 23 Exploded Drawing Ti 2002 24 Part...

Страница 4: ...oose clothing or jewellery to start or operate the gen erator Loose clothing or jewellery may become entangled in moving components causing equipment damage and or personal injury 10 Be aware of movin...

Страница 5: ...ator with power cords or by any means to move it only move the generator with the carrying handles 31 Never cover the generator or restrict the exhaust or air flow in any way 32 Always ensure that the...

Страница 6: ...overheating or damage to the equipment as well again if you are unsure ask a suitably qualified electrician Caution Never attempt to connect the generator directly to the electrical system of any buil...

Страница 7: ...M5x16 PW01 00170 108 18 Washer M5 PW01 00170 108 17 Spring Washer M5 PW01 00170 109 Hex Bolt M6x30 PW01 00171 108 18 Washer M5 PW01 00170 110 Flange Bolt M5x8 PW01 00172 109 Hex Bolt M6x30 PW01 00171...

Страница 8: ...00151 54 25 Step Motor Support PW01 00140 77 Cross Head Screw M5x30 PW01 00152 54 26 Choke Lever Assembly PW01 00140 78 Maintenance Cover Left PW01 00153 54 27 Washer M3 PW01 00140 79 Bolt M6x16 PW01...

Страница 9: ...00018 51 Washer M6 PW01 00086 18 Recoil PW01 00117 52 Spring Washer M6 PW01 00087 19 Flange Bolt M6x12 PW01 00008 53 Flange Bolt M6x25 PW01 00139 20 Fuel Tank Cap PW01 00118 54 Carburettor Complete PW...

Страница 10: ...Recoil Starter 3 Fuel Cap 12 DC Socket 4 Primer Bowl 13 DC Circuit Breaker 5 Fuel Valve 14 AC Socket 6 Maintenance Panel A 15 Low Oil Indicator 7 Engine Switch 16 Pilot Power Indicator 8 Earth Ground...

Страница 11: ...77 129 Flange Bolt M10x1 PW01 00100 96 Air Filter Cover PW01 00078 130 Fan Hood PW01 00101 97 Self Tapping Screw M4x12 PW01 00079 131 Self Tapping Screw 3 5x12 PW01 00102 98 Plastic Case Left PW01 000...

Страница 12: ...00027 8 Flange Bolt M6x12 PW01 00008 42 Tube Sleeve PW01 00035 9 Starter Cover PW01 00009 43 Fuel Tank Rubber Seal PW01 00036 10 Washer M8 PW01 00010 44 Inverter Block PW01 00037 11 Flange Bolt M6x16...

Страница 13: ...on 1 position Step 2 Turn the fuel tap to the on position Step 3 Slide the choke lever to the left Note The choke may not be needed if the engine is already warm or the ambient temperature is hot 039...

Страница 14: ...n unclean area 1 Remove the M6 screws and open the muffler cover 2 Remove the two M4 screws on the spark arrestor 3 Take out the spark arrestor 4 Check the spark arrestor clean or replace if necessary...

Страница 15: ...heck the overall condition of the plug and replace if damaged 7 Reinstall the plug spark plug cap and maintenance panel Check The Fuel Tank Filter periodically Just under the fuel cap is a fuel filter...

Страница 16: ...nerator In an emergency simply press the engine switch to the off position In normal conditions Remove any load from the generator Turn the fuel tap to off Press the engine switch to the off position...