6. Package Contents

No.

Contents

1

Device (contain mounting kit) * 1

2

Terminal block * 1 set

3

Installation guide card * 1

C2000-A1-SDD1010-AB3 User Manual

33 / 34

SinoCon Co., Ltd. 

www.sinoconsys.com

Содержание KonNaD C2000-A1-SDD1010-AB3

Страница 1: ...Last updated 2020 1 10 C2000 A1 SDD1010 AB3 User Manual Ethernet 1DI 1DO Remote I O Module Ethernet Digital I O Module SinoCon Co Ltd...

Страница 2: ...us 3 2 2 DO Power on Status 3 3 Other Features 3 3 1 DI Pulse Mode 3 3 2 Filter Parameters 3 3 3 Zeroing 4 Software Tools 4 1 Main Screen 4 2 Use Software 4 2 1 Device Settings 4 2 2 View Device Statu...

Страница 3: ...liability stated by SinoCon in the terms and conditions of sale of its products and SinoCon makes no warranties regarding the sale or use of KonNaD products including the suitability for the specific...

Страница 4: ...re 1 2 Wiring Refer to Port Description for the recommended wires After the device is powered on the PWR is steady red the RUN is flashing which indicates the device is powered normally Plug the netwo...

Страница 5: ...l pop up to direct you to complete the installation 1 3 2 Device Debug Search Devices Select Search for Ethernet devices and Click Search to find all devices in the LAN Change IP Address Double click...

Страница 6: ...left corner of the software to see all the point value of the device Read the status of DI The value 0 indicates Open the value 1 indicates Short to GND Use a wire to short the DI1 and GND you can se...

Страница 7: ...Refer to Registers for information on Secondary Development C2000 A1 SDD1010 AB3 User Manual 7 34 SinoCon Co Ltd www sinoconsys com...

Страница 8: ...annels 1 DO Connector Terminal block DO Type Form C DO Mode Logic Level Contact Capacity 30V 3A Ethernet No of Ports 1 Bandwidth 10 100M Communication Distance 100m Industrial Protocols Standard Modbu...

Страница 9: ...ristics Dimensions 75 105 30mm Installation Din rail or wall Environmental Limits Operating Temperature 40 85 Storage Temperature 60 125 Ambient Relative Humidity 5 95 RH non condensing Classification...

Страница 10: ...2 2 Apprearance C2000 A1 SDD1010 AB3 User Manual 10 34 SinoCon Co Ltd www sinoconsys com...

Страница 11: ...0M network Downstream Serial Port RXD RS485 data receive indicator Steady on RS485 line fault please check if the positive and negative poles of 485 line are reversed Flashing RS485 receiving data Off...

Страница 12: ...OM Digital output common RVV 2 1 0 NC Digital output normally close RVV 2 1 0 Ethernet Ethernet RJ45 Ethernet port CAT 5e Downstream Serial Port 485 485 RS485 RS485 downward RVSP 2 1 0 Power Input V V...

Страница 13: ...2 5 Product Dimensions unit mm inch 2 6 Installation Method C2000 A1 SDD1010 AB3 User Manual 13 34 SinoCon Co Ltd www sinoconsys com...

Страница 14: ...atus 0x05 function code is used to write single DO status and 0x0F function code is used to write multiple DO status simultaneously 3 2 2 DO Power on Status It controls DO status when the device is ju...

Страница 15: ...ed This value can be modified according to the site conditions and the range is 0 20 3 3 3 Zeroing When set to auto zero the DI positive negative pulse count or DI logic level count value will be auto...

Страница 16: ...and cannot be searched the device parameters can be modified through Remote Set 3 Change Password Modify password of Ethernet type devices 4 Clear Password Clear password of Ethernet type devices If y...

Страница 17: ...device and you can modify the point value of the device 12 Refresh Used to refresh the point value of the device after it changes 4 2 Use Software 4 2 1 Device Settings Select Search for Ethernet dev...

Страница 18: ...it will actively connect to the server Here the concept of the Socket of the Server Client is not to be confused with the application s Server Client Listening port The listening port waits for the c...

Страница 19: ...to 2 Click Add to add the cascading device in the pop up 4 2 2 View Device Status After setting the IP address of the device and the computer on the same network segment click Refresh in the lower le...

Страница 20: ...atus is set to 1 the DO1 indicator is on and when the DO1 Status is set to 0 the DO1 indicator is off The Power on state of DO can be controlled When DO1 Mode is Level mode the DO1 Power on state is s...

Страница 21: ...t be searched the device parameters can be modified through Remote Set Click Remote Set in the upper left corner of the software the pop up dialog box to fill in the device IP address the port 21678 i...

Страница 22: ...RW e g 10 1 1 11 0x0B01010A 1st register low 2 bytes of IP 0x010A 2nd register high 2 bytes of IP 0x0B01 0x03 0x06 0x10 40107 1 Modbus TCP port RW e g Default 502 01 F6 0x03 0x06 0x10 40108 1 Reserved...

Страница 23: ...cts to the server through the server IP or domain name 0x03 0x06 0x10 40152 1 Reserved field RW Read as 0 write invalid 0x03 0x06 0x10 40153 1 Weather to auto upload RW 0 No default 1 Yes The devices...

Страница 24: ...g count from the written value 0x03 0x06 0x10 40304 1 DI1 level change count RW Range from 0x0000 0xffff any value can be written After writing count from the written value 0x03 0x06 0x10 40305 1 DI1...

Страница 25: ...Bytes identification of a Modbus Request Response transaction 0000 Protocol ID 2 Bytes 0000 Modbus protocol 0004 Length Field 2 Bytes number of following bytes FF Unit ID 1 Byte 0xFF Master device 01...

Страница 26: ...0006 Length Field 2 Bytes number of following bytes FF Unit ID 1 Byte 0xFF Master device 0F Function Code 1 Byte 0F Write 0064 Starting Address 2 Bytes address of the first register 0001 Quantity of...

Страница 27: ...e single register 0064 Starting Address 2 Bytes address of the first register FF00 Data 2 Byte FF00 indicates COM and NO is close 5 2 4 Read DI Status 0x02 Take the case of acquisition 1 channel DI as...

Страница 28: ...000100000006FF03012C0001 Command Field Description 0001 Transaction ID 2 Bytes identification of a Modbus Request Response transaction 0000 Protocol ID 2 Bytes 0000 Modbus protocol 0006 Length Field 2...

Страница 29: ...06012E000F Command Field Description 0001 Transaction ID 2 Bytes identification of a Modbus Request Response transaction 0000 Protocol ID 2 Bytes 0000 Modbus protocol 0006 Length Field 2 Bytes number...

Страница 30: ...ponse transaction 0000 Protocol ID 2 Bytes 0000 Modbus protocol 0009 Length Field 2 Bytes number of following bytes FF Unit ID 1 Byte 0xFF Master device 10 Function Code 1 Byte 10 Write 0130 Starting...

Страница 31: ...bytes 01 Unit ID 1 Byte 01 RS485 address of the cascading device 02 Function Code 1 Byte 02 Read 00C8 Starting Address 2 Bytes address of the first register 0004 Quantity of Registers 2 Bytes the numb...

Страница 32: ...ode 1 Byte 0F Write 0064 Starting Address 2 Bytes address of the first register 0004 Quantity of Registers 2 Bytes the number of required registers 01 Data Length 1 Byte Data Length 03 Data 1 Byte 03...

Страница 33: ...6 Package Contents No Contents 1 Device contain mounting kit 1 2 Terminal block 1 set 3 Installation guide card 1 C2000 A1 SDD1010 AB3 User Manual 33 34 SinoCon Co Ltd www sinoconsys com...

Страница 34: ...period or that have been improperly installed incorrectly input voltage improperly used accidental events or natural disasters etc are not covered by the warranty 3 Before accepting the warranty serv...

Отзывы: