IDD-213W User Manual
18
The suggested minimal interval for GPS report is 10s. For example, if only sampled by
time interval is enabled, then the settings might be 10s of sample rate and 1 group of
GPS data per message, or 5s of sample rate and 2 groups of GPS data per message.
5
5..4
4
R
Re
eg
gu
ulla
arr G
G--S
Se
en
nsso
orr D
Da
atta
a R
Re
ep
po
orrttiin
ng
g
Device reports G-Sensor data (g-value of X/Y/Z axis) according to configured time
interval, this function is disabled by default.
The sample rate can be 200-6000ms and default setting is 1000ms.
There can be single or several groups of G-Sensor data in one G-Sensor message,
determined by groups of G-Sensor data per message, device will not report G-Sensor
message until it has collected specified groups of G-Sensor data. Groups of G-Sensor
data per message can be 50-100 and default setting is 100.
5
5..5
5
R
Re
eg
gu
ulla
arr D
Diia
ag
gn
no
ossttiicc D
Da
atta
a R
Re
ep
po
orrttiin
ng
g
Device is able to read variety of vehicle diagnostic data, also called PID (parameter ID),
including vehicle speed, engine RPM, engine coolant temperature, mass flow air, etc,
and report up to 10 types of PID data according to configured time interval.
The sample rate can be 2-600s and default setting is 60s.
There can be single or several groups of PID data in one PID message, determined by
groups of PID data per message, device will not report PID message until it has
collected specified groups of PID data. Groups of PID data per message can be 1-30
and default setting is 1.
The suggested minimal interval for PID report is 10s, for example, 10s of sample rate
and 1 group of PID data per message, or 5s of sample rate and 2 groups of PID data
per message.
5
5..6
6
D
DT
TC
Css R
Re
ep
po
orrttiin
ng
g
Device is able to read vehicle pending and stored DTCs (diagnostic trouble code), and
freeze frame data. The backend server analyzes and displays the DTCs for users on
time to avoid high repairing cost.
5
5..7
7
C
Ce
ellll IID
D R
Re
ep
po
orrttiin
ng
g
Device reports Cell ID every 30 seconds when it loses GPS signal, this function is
disabled by default.