© Copyright 2017-2022 LBC Bakery Equipment, Inc. 22 Rev 6/2022
CONTROL SETUP (Part 2 of 3)
.
The oven control can be tailored to operate differently, depending on the customer.
Here is a list of the configurable parameters:
•
Sb – Temperature Set-back causes the control to reduce the thermostat setting
when the oven is running, but not being used for more than a selected time. The
oven is not being used when the door remains closed, and the timer is not
running. Sb can be set to “On” or “OF”.
•
St – Set-back Temperature determines what the thermostat will be when set-
back occurs. It can also be set to “00” and cause the oven to turn off when the
set-back time is reached. St is shown in 10-degree increments.
•
Id – Idle delay is the selected time that the oven can be unused before set-back
occurs. Id is shown in ten-minute increments and can be set for 10 minutes, up
to 120 minutes.
•
IL – Idle Illumination can be set to “On”, where the interior light and rack rotator
will continue to operate when the door is closed and the oven is on, or to “OF”,
where the interior light and the rack rotator will be off if the oven door is closed,
and the timer is not running for more than 45 seconds.
•
PL – Programming Limitation limits the user from accessing certain function and
changing pre-set recipes. PL can be set to “On” to turn on the limits or “OF” to
allow user access and recipe changes.
•
FC – F or C temperature restrictions fixes the temperature display in Degrees “F”,
Degrees “C” or allows the user to change the display when set to “B”.
•
tP – Step Function; “On” allows the use of recipe steps. “OF” prohibits the use of
recipe steps. Turning steps on or off requires that the entire recipe list must be
re-written.
•
T4 – The maximum steam time that the user can select is set from 1 to 99
seconds.
•
T5 – Proportional Steam for user settings up to 59 seconds, in seconds ON for
every 10 seconds. “01” will turn the water on for 1 second, then off for 9
seconds and then repeats. “10” turns the water on continuously until the user
set steam time or the T6 limit is reached.
•
T6 – Maximum total water that will be dispensed in a user set steam cycle set for
up to 59 seconds is set in seconds.
Содержание LBC LMO Max-E
Страница 21: ... Copyright 2017 2022 LBC Bakery Equipment Inc 21 Rev 6 2022 CONTROL OPERATION SETUP Part 1 of 3 ...
Страница 25: ... Copyright 2017 2022 LBC Bakery Equipment Inc 25 Rev 6 2022 NOTES ...
Страница 37: ... Copyright 2017 2022 LBC Bakery Equipment Inc 37 Rev 6 2022 ELECTRICAL SCHEMATICS Part 2 of 4 ...
Страница 38: ... Copyright 2017 2022 LBC Bakery Equipment Inc 38 Rev 6 2022 ...
Страница 39: ... Copyright 2017 2022 LBC Bakery Equipment Inc 39 Rev 6 2022 ELECTRICAL SCHEMATICS Part 3 of 4 ...
Страница 40: ... Copyright 2017 2022 LBC Bakery Equipment Inc 40 Rev 6 2022 ELECTRICAL SCHEMATICS Part 4 of 4 ...