6.6 Timer operation

Timer ON setting:

-

When the air-conditioner is OFF, press the “Timer” button and select a desired ON time through the

temperature and time setting buttons.

-

“Preset ON Time” is displayed on the operation panel.

-

ON time can be regulated at any time in 0-24 hours.

Timer OFF setting

-

When the air-conditioner ON, press “Timer” button and select a desired OFF time through the
temperature and time setting buttons.

-

“Preset OFF Time” is displayed on the operation panel.

-

OFF time can be regulated at any time in 0-24 hours.

6.7 Auto SWING

After machine turns on, press this key, the louver will swing continuously left and right; by pressing this
button again the movement will stop and the louver remain in that position.

6.8 SLEEP mode

- While in cooling mode, press the SLEEP key to set the temperature. It increases 1°F after an hour and

at most increases 2°F after 2 hours.

- While in heating mode, press the SLEEP key to set the temperature. It decreases 1°F after an hour and

at most decreases 2°F after 2 hours.

- Press the SLEEP key again can cancel the setting.

6.9 Water drainage

Water Full Alarm

The inner water tray inside the air-conditioner has one water level safety switches, it controls
water level. When water level reaches an anticipated height, the water full indicator lamp lights
up. (If water pump is damaged, when the water is full, please remove the rubber blockage at the
bottom of unit, and all water will drain outside.)

Continuous Drainage

- When you plan to leave this unit unused for a long time, please remove the rubber blockage from

the drainage hole at the bottom of unit, and connect a drain hose to the lower fixing clip. All the
water in the water tank will drain outside.

- You can drain the water as the above when the unit working at the HEAT mode.
- If water pump is damaged, continuous drainage can be used, and under this condition, the water

pump is not activated. The unit can also work well.
If water pump is damaged, intermittent drainage can also be used. Under this condition, when
the water full indicator lamp lights up, please connect a drain hose to the lower fixing clip, then
all the water in the water tray will be drained outside. The unit can also work well.

Содержание SLK-KY018-12KC/E

Страница 1: ...able Air conditioner User s Manual R32 For Model SLK KY018 12KC E SLK KY018 14KC E Thank you for using our product Please read this user s manual carefully to ensure proper use maintenance and installation ...

Страница 2: ... Name of Parts 3 3 Accessories 4 4 Appearance and Function of Control Panel 5 5 Appearance and Function of Remote Control 6 6 Operation Introduction 7 7 Installation Explanations 10 8 Maintenance Explanations 15 9 Troubleshooting 16 ...

Страница 3: ...er supply and move it slowly 8 To avoid the possibility of fire disaster the air conditioner shall not be covered 9 All the air conditioner sockets must comply with the local electric safety requirements If necessary please check it for the requirements 10 Children should be supervised to ensure that they do not play with the appliance 11 If the supply cord is damaged it must be replaced by the ma...

Страница 4: ...ircuit should hold a current valid certificate from an industry accredited assessment authority which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification 19 Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried...

Страница 5: ...Page 3 2 Name of Parts Fig 1 1 Louver 6 Drainage outlet 2 Control panel 7 Air outlet 3 Front panel 8 Power cord 4 Castor 9 Drainage outlet 5 Air inlet 2 Name of Parts ...

Страница 6: ......

Страница 7: ...odel A Power on off 3 Dehumidifying B Fan speed 4 Fan C Temperature up 5 Auto swing D Temperature down 6 Low fan speed E Operation mode 7 Medium fan speed F Timer on off 8 High fan speed 1 Sleep mode 9 Water full 2 Cooling 4 Appearance and Function of Control Panel ...

Страница 8: ...exposed to direct sunlight 1 Power on off 2 Timer on off 3 Operation MODE 4 C F selector 5 Temperature up 6 Temperature down 7 LED display 8 Auto swing 9 Fan speed 10 Sleep mode 1 Receiver signal 2 Cooling 3 Dehumidifying 4 Fan 5 Auto swing 6 Timing 7 Timer on off 8 Sleep mode 9 Fan speed 10 Temperature display 5 Appearance and Function of Remote Control ...

Страница 9: ... 2 As shown in Fig 5 and Fig 5a install the exhaust hose and adjust the window position well Fig 5 Fig 5a 3 As shown in Fig 6 Connect drain hose well only for using heating model 4 Insert the power cord into an grounded AC115V 60Hz socket 5 Press the POWER button to turn on the air conditioner Fig 6 6 Operation Introduction ...

Страница 10: ...temperature 61 F 88 F Press the WIND button to select wind speed 6 3 Dehumidifying operation Press the Mode button till the Dehumidify icon appears Automatically set the selected temperature to current room temperature minus 2 F 61 F 88 F Automatically set the fan motor to LOW wind speed 6 4 Fan operation Press the Mode button till the Fan icon appears Press the WIND button to select wind speed 6 ...

Страница 11: ...eases 2 F after 2 hours Press the SLEEP key again can cancel the setting 6 9 Water drainage Water Full Alarm The inner water tray inside the air conditioner has one water level safety switches it controls water level When water level reaches an anticipated height the water full indicator lamp lights up If water pump is damaged when the water is full please remove the rubber blockage at the bottom ...

Страница 12: ...and the window Connector to the ends of the exhaust hose 2 Insert the fixing clip of the housing adaptor into the openings at back of the air conditioner 3 Put the other end of the exhaust hose to the near windowsill see Fig 9 Window Kit Installation The installation manner of window slider kit is mostly in horizontal or vertical As shown Fig 10 and Fig 10a check the min and max size of the window...

Страница 13: ...Page 11 Fig 9 Fig 10 Fig 10a Fig 11 ...

Страница 14: ... dimensions of the window Glue them to the frame of your window and then do the same on the inner surface of the window flap on the side of the handle 3 Glue the widest side A of the large white fabric piece to the window frame and then glue the narrower side B to the window leaf handle side from the center then up and finally down 4 Close the window and make sure the large fabric piece is not stu...

Страница 15: ...level of the bottom or middle of the window then insert the exhaust duct into the opening Readjust the zipper so that the exhaust duct is attached so that there is no air exchange between the inside and the outside 6 Your caulking kit is now installed you can now turn on and enjoy the coolness of your mobile air conditioner If you no longer want to use your mobile air conditioner and close your wi...

Страница 16: ...ne water level safety switches it controls water level When water level reaches an anticipated height the water full indicator lamp lights up If water pump is damaged when the water is full please remove the rubber blockage at the bottom of unit and all water will be drained outside ...

Страница 17: ...e air filter becomes clogged with dust dirt the air filter should be cleaned once every two weeks Dismounting Open the air inlet grille and take off air filter Cleaning Clean the air filter with neural detergent in lukewarm 104 F and dry it up in the shade Mounting Putting the air filter into the inlet grille replace the components as they were 8 2 Clean the Air conditioner Surface First clean the...

Страница 18: ... if possible Exhaust air hose is not connected or blocked Connect or clean the exhaust air hose Temperature setting is too high Reset the temperature Air inlet is blocked Clean the air inlet 3 Noisy The ground is not level or not flat enough Place the unit on a flat level ground if possible The sound comes from the flowing of the refrigerant inside the air conditioner It is normal 4 E0 Code Room t...