f) Insert the wire leads into Plug (Cable Adapter) connectors. 

 

   Using a 5/64" Allen Wrench tighten the set screws (Fig. 6). 

 

g

) Slide the Inner Cable Boot (Part B) over the plug until it is flush with  

                   the first step on the collar (Fig. 6). 
                  Wipe the grease from the surface of Inner Cable Boot and cable. 
                    Tape end of Inner Cable Boot tightly to the cable.  
                   Be sure to tape 4 in. (10 cm) below the Inner Cable Boot on the cable. 

Note:   This taped area allows the  Outer Cabl e Boot (Part C) to slide freely over the Inner Cabl e Boot.  

DO NOT REMOVE THE TAPE. 

 

h)  Lubricate the outer surface of the Inner Cable Boot and tape with supplied O-Ring grease.  

 

     Slide the Outer Cable Boot (Part C) over the Inner Cable Boot until it is flush with  

 

     the second step on the collar (Fig. 6). 

 

i) Push the Plug (Cable Adapter) into the Receptacle (Cable Adapter) until the collar is seated flush. 

NOTE:  The ori entation of the Pl ug(Cabl e Adapter) will not effect the pumps performance.

 

j) Push the Nut (Part D) over the Plug (Cable Adapter) and then finger tighten the nut. 

NOTE:

  Before continuing, operate the pump to check all electrical connections, 

 

    using the correct power supply. 

Refer to Technical Specifications (Pg. 14).

         If pump does not operate Refer to 

"Helpful Hints" 

(Page 8) before continuing . 

3) 

Install the 6 in. hose and fitting (1/2" NPT X 1/2" BARB) (Fig. 7, page 5). 

a) Press the fitting into the 6 in. hose, slide the clamp on the hose and over the fitting and tighten the clamp securely.

b) Slide another clamp on the 6 in. hose, slide the assembly over the barbed fitting on the pump, 

                   and tighten the clamp securely. 

Note: Sel ect the proper adapter hos e and accessori es for the pump. 

USE OF DISCHARGE PIPE LARGER THAN 3/4" IS NOT RECOMMENDED.. 

 

Use 150 P.S.I. Min. (10 bars) working pressure rated 1/2 in. I.D. (12.7 mm I.D.) 

smooth bore hose

 (Part not included.). 

 

Use All-Stainless Steel hose clamp (Part not included. 

1 /2 " N PT

Содержание 2440 Series

Страница 1: ...User Manual SUBMERGED PUMP ENGLISH...

Страница 2: ...440 Series Submersible Pump The engineers and technicians who designed and manufactured these pumps have developed these instructions from their experiences These instructions should be read completel...

Страница 3: ...nt past the end of lead wires Fig 4 Generously lubricate the cable 4 to 6 in 10 to 15 cm with supplied O Ring grease d Slide the cable boot components over the cable Part A in the following order Fig...

Страница 4: ...llar is seated flush NOTE The orientation of the Plug Cable Adapter will not effect the pumps performance j Push the Nut Part D over the Plug Cable Adapter and then finger tighten the nut NOTE Before...

Страница 5: ...installing the pump fill in the application worksheet on pages 14 15 The application worksheet is a guide to make sure that the pump is installed properly in the well Following the guidelines laid out...

Страница 6: ...BYPASS 3 Q POPPET BYPASS 3 R VALVE HOUSING ASSEMBLY 1 S LOWER HOUSING ASSEMBLY 1 T MOTOR 1 U CANISTER 1 V SCREW CANISTER 3 W LOCK WASHER MOTOR SCREW 3 REPLACEMENT PART KITS 24 135 00 LIFT PLATE E F I...

Страница 7: ...M L K J I G F E D C B A W F H R Q VIEW A P 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Lift Plate Cable Plug Valve Lower Housing Motor Canister Filter Screen O Ring 24 135 00 24 136 00 24 137 00 24 138 00 24 139...

Страница 8: ...RINSE SCREEN REFER TO REMOVAL AND DISASSEMBLY SECTION Pg 9 5 FLUID PATH IN 5 CHECK FOR PINCHED HOSE CLOGGED PLUMBING RESTRICTED LINES 6 LOOSE CONNECTIONS 6 CHECK HOSE CLAMPS or REPLACE HOSE Pg 4 or P...

Страница 9: ...ly Fig 9 Remove the Nut Part D unscrewing it counterclockwise and pull the plug up 4 Remove the Lift Plate Part F Fig 9 Using a 2 Phillips Screwdriver remove the screws Part E from 6 places and pull u...

Страница 10: ...g Assembly contains small parts Be careful not to lose parts after removing Upper Housing a Using a 5 32 Allen Wrench remove the screws Part L from 3 places b Before separating the Upper Housing from...

Страница 11: ...bly Parts R Fig 11 Place the Valve Housing Assembly into the Upper Housing Part N Note Make sure that the inlet valves are centered on top of the bypass Poppets Part Q 4 Install the Lower Housing Asse...

Страница 12: ...HE ASSEMBLY TOGETHER b Using a 5 32 Allen Wrench tighten the screws on the first pass with 25 5 in lb 2 8 Nm 5 torque c Tighten the screws on the second pass with 65 5 in lb 7 3 Nm 5 torque 10 Connect...

Страница 13: ...2 25 Nm 5 TORQUE TO PREVENT STRIPPING b Using a 2 Phillips Screwdriver install the screws Part E 6 places into the Lift Plate 14 Install the Plug Cable Adapter Assembly Note The orientation of the Plu...

Страница 14: ...____ SOLAR ARRAY INFORMATION MAKE MODEL_______________________________________________________________________________________________ WATTS AVAILABLE NO OF PANELS X WATTS PER PANEL __________________...

Страница 15: ...l changes in the region TOTAL VERTICAL LIFT H1 H2 H3 12 VDC FLOW CHART TOTAL FLOWRATE SOLARARRAYSIZE CURRENT VERTICAL LIFT PERHOUR MINIMUMTOTAL POWERRATING AMPS S T T A W R T L L A G S R E T E M T E E...

Страница 16: ...BYPASS 105 110 P S I MAX 7 2 7 5 bars MAXIMUM LIFT 230 ft 70 M MAXIMUM SUBMERSION 100ft 30 M OUTLET PORT 1 2 12 7 mm I D Barbed Fitting for 1 2 I D 12 7 mm I D Tubing INLET 50 MESH STAINLESS STEEL SCR...

Страница 17: ...___________________________ ____________________________________________________________________________________________ _______________________________________________________________________________...

Страница 18: ...faulty due to manufacturing defects will be repaired or replaced at no charge This warranty does not apply to any damage resulting from misuse negligence accidents improper installation or wiring Abu...

Отзывы: