SINGFLO 2440 Series Скачать руководство пользователя страница 18

 

WARRANTY

LIMITED WARRANTY PROCEDURE

SINGFLO

  warrants  its  pump  to  be  free  of  defects  in  material  and  workmanship  to  the  original  retail 

purchaser  for  the  period  of  one  year beginning with  the  purchase date  of  the unit  or, in  the  absence  of 

proof  of  purchase  date,  one  year  from  the  date  of  manufacture  as  shown  on  the  pump,  not  to  exceed 

two  (2)  years  in  any  event.  Each  pump  has  been  operated  and  tested  before  being  shipped  from 

SINGFLO

's factory. During the warranty period if the pump is not operating correctly, you may return it 

freight pre-paid to your local distributor, dealer or directly to 

SINGFLO

.  

Upon 

SINGFLO

's  inspection,  any  unit  found  faulty  due  to  manufacturing  defects  will  be  repaired  or 

replaced  at  no  charge.  This warranty  does  not  apply  to  any  damage  resulting  from  misuse,  negligence, 

accidents,  improper  installation  or  wiring.  Abuses  such  as  removal  of  the 

SINGFLO

  label,  improper 

repair,  installation,  application,  or  damaged  lower  housing  assembly  due  to  running  dry,  are  also  not 

considered warrant able.  There will be charges applied for any of   the above mentioned non-warrantable 

items. 

If  you  send  the  pump  to  us  for  prompt  repair,  please  package  it  carefully  to  avoid  shipping  damage. 

Enclose  your  name,  address,  a  phone  number  where  you  may  be  reached  and  your  proof  of  purchase 

date. 

The  above  represents  our  warranty  policy.  Under  no  circumstances  will  we  assume  or  accept 

responsibility for unauthorized expenditures, losses, or any costs greater than the basic pump value. 

 

 

 

 

Содержание 2440 Series

Страница 1: ...User Manual SUBMERGED PUMP ENGLISH...

Страница 2: ...440 Series Submersible Pump The engineers and technicians who designed and manufactured these pumps have developed these instructions from their experiences These instructions should be read completel...

Страница 3: ...nt past the end of lead wires Fig 4 Generously lubricate the cable 4 to 6 in 10 to 15 cm with supplied O Ring grease d Slide the cable boot components over the cable Part A in the following order Fig...

Страница 4: ...llar is seated flush NOTE The orientation of the Plug Cable Adapter will not effect the pumps performance j Push the Nut Part D over the Plug Cable Adapter and then finger tighten the nut NOTE Before...

Страница 5: ...installing the pump fill in the application worksheet on pages 14 15 The application worksheet is a guide to make sure that the pump is installed properly in the well Following the guidelines laid out...

Страница 6: ...BYPASS 3 Q POPPET BYPASS 3 R VALVE HOUSING ASSEMBLY 1 S LOWER HOUSING ASSEMBLY 1 T MOTOR 1 U CANISTER 1 V SCREW CANISTER 3 W LOCK WASHER MOTOR SCREW 3 REPLACEMENT PART KITS 24 135 00 LIFT PLATE E F I...

Страница 7: ...M L K J I G F E D C B A W F H R Q VIEW A P 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Lift Plate Cable Plug Valve Lower Housing Motor Canister Filter Screen O Ring 24 135 00 24 136 00 24 137 00 24 138 00 24 139...

Страница 8: ...RINSE SCREEN REFER TO REMOVAL AND DISASSEMBLY SECTION Pg 9 5 FLUID PATH IN 5 CHECK FOR PINCHED HOSE CLOGGED PLUMBING RESTRICTED LINES 6 LOOSE CONNECTIONS 6 CHECK HOSE CLAMPS or REPLACE HOSE Pg 4 or P...

Страница 9: ...ly Fig 9 Remove the Nut Part D unscrewing it counterclockwise and pull the plug up 4 Remove the Lift Plate Part F Fig 9 Using a 2 Phillips Screwdriver remove the screws Part E from 6 places and pull u...

Страница 10: ...g Assembly contains small parts Be careful not to lose parts after removing Upper Housing a Using a 5 32 Allen Wrench remove the screws Part L from 3 places b Before separating the Upper Housing from...

Страница 11: ...bly Parts R Fig 11 Place the Valve Housing Assembly into the Upper Housing Part N Note Make sure that the inlet valves are centered on top of the bypass Poppets Part Q 4 Install the Lower Housing Asse...

Страница 12: ...HE ASSEMBLY TOGETHER b Using a 5 32 Allen Wrench tighten the screws on the first pass with 25 5 in lb 2 8 Nm 5 torque c Tighten the screws on the second pass with 65 5 in lb 7 3 Nm 5 torque 10 Connect...

Страница 13: ...2 25 Nm 5 TORQUE TO PREVENT STRIPPING b Using a 2 Phillips Screwdriver install the screws Part E 6 places into the Lift Plate 14 Install the Plug Cable Adapter Assembly Note The orientation of the Plu...

Страница 14: ...____ SOLAR ARRAY INFORMATION MAKE MODEL_______________________________________________________________________________________________ WATTS AVAILABLE NO OF PANELS X WATTS PER PANEL __________________...

Страница 15: ...l changes in the region TOTAL VERTICAL LIFT H1 H2 H3 12 VDC FLOW CHART TOTAL FLOWRATE SOLARARRAYSIZE CURRENT VERTICAL LIFT PERHOUR MINIMUMTOTAL POWERRATING AMPS S T T A W R T L L A G S R E T E M T E E...

Страница 16: ...BYPASS 105 110 P S I MAX 7 2 7 5 bars MAXIMUM LIFT 230 ft 70 M MAXIMUM SUBMERSION 100ft 30 M OUTLET PORT 1 2 12 7 mm I D Barbed Fitting for 1 2 I D 12 7 mm I D Tubing INLET 50 MESH STAINLESS STEEL SCR...

Страница 17: ...___________________________ ____________________________________________________________________________________________ _______________________________________________________________________________...

Страница 18: ...faulty due to manufacturing defects will be repaired or replaced at no charge This warranty does not apply to any damage resulting from misuse negligence accidents improper installation or wiring Abu...

Отзывы: