Singer Instruments ROTOR HDA Скачать руководство пользователя страница 18

18

software icon guiDe

AdVANce OPTiONs

IcOn

nAME

SETTIng

DEScrIPTIOn

TAb

UnIT

MIn

MAx DEFAUlT

Off

Full

Until 
repeat

during 
Pairs

revisit 
source

repeat 
Pairs

Off

Automatic

random

recycle

recycle

recycle

recycle

On/Off

On/Off

On/Off

Plate 
Protection

Offset

Offset

Offset

rePads™/pins are always dumped.

rePads™/pins are recycled for the 
duration of the program.

rePads™/pins are recycled for the 
duration of one cycle of the program.

rePads™/pins are recycled for the 
duration of each pinning pair.

revisit ensures that the source is 
revisited for each pinning. if revisit 
source if off, the source plate will not 
be revisited unless a new position on 
the source plate is being pinned.

By protecting the source plates you 
can ensure that lids are only removed 
when it is vital to do so. This will 
increase the time it takes to run each 
program, but each source plate will 
be exposed for less time, and the 
print head will never move over a 
source plate without a lid on, unless 
it is pinning from it

A pinning pair represents pinning 
from a source plate to a target plate. 
you can adjust how many times 
each of these pairs are repeated. 
during pair repetition, recycle and 
revisit mode rules will be followed 
as normal.

No offset is used for source pinning.

An automatic offset is used for each 
source pinning.

A random offset is used for each 
source pinning.

General>recycle

N/A

N/A

N/A

N/A

Boolean

Boolean

Boolean

Boolean

Boolean

Boolean

N/A

N/A

N/A

N/A

Off

Off

Off

Off

Off

Off

N/A

N/A

N/A

N/A

On

On

On

On

On

On

N/A

N/A

N/A

N/A

Off

Off

Off

Off

Off

Off

General>recycle

General>recycle

General>recycle

General>recycle

General>Plate 
Protection

General>Pairs

source>Offset

source>Offset

source>Offset

Содержание ROTOR HDA

Страница 1: ...User Guide v1 2...

Страница 2: ...R HDA require moving During Pad Head removal always ensure the push cylinder is cleared before moving away from the carriage The push cylinder runs from the carriage arm into The Stinger Pad Head If e...

Страница 3: ...tra fast manipulation of high density arrays of yeast other fungi and bacteria Reagent sets such as deletion mutant collections and the complete set of cloned yeast genes can be utilised for high thro...

Страница 4: ...en Protective Screen Screen Handle Lid Lifters Turntable Hopper Control Panel Pad Head Emergency Stop Carriage Arm RS232 Shuttle Input Dump Zone Hopper Loading Bay Black Bay Dump Drawer Fast Buttons U...

Страница 5: ...my features Beer Bottle Opener Air Line Connection NOTE Ensure to keep transit hardware in a safe place should the ROTOR HDA require moving Removable Transit Clamps Removable Transit Bar MCI Mounting...

Страница 6: ...er is where the fresh RePads are loaded Load a stack of RePads pins facing down into the Hopper as shown ensuring the chamfered corner is to the top right The Pad Hopper is fully autoclavable to ensur...

Страница 7: ...Solid agar Solid agar Solid agar Solid agar Liquid Solid agar 96 short Compatible densities Compatible densities Compatible densities Compatible densities Compatible densities Compatible densities Co...

Страница 8: ...irst The turntable will then rotate to allow you to load the second two The Pad Head moves to the Source Plate lowers and collects a sample of cells The Pad Head lowers and picks up a RePad The Pad Ho...

Страница 9: ...repeated until your chosen protocol is finished Follow the simple step by step instructions for loading unloading of plates and consumables See page 14 The Pad Head moves to the Dump Zone and drops t...

Страница 10: ...o work through the ROTOR HDA initialisation procedure Turn on the Compressor Select OK on the Touch Screen or use the Fast Buttons Open the Roll over Cover OK Cancel Insert the Power Cables into the R...

Страница 11: ...ents com 4 5 Initialisation routine Clear all objects from the ROTOR Stage so nothing will obstruct the initialisation routine Select OK On screen or use the Fast Buttons The ROTOR HDA will perform a...

Страница 12: ...s on The source could be colonies grown on solid agar or cultures grown in liquid media In solid agar the ROTOR HDA currently supports colony density up to 24576 In liquid media the ROTOR HDA supports...

Страница 13: ...media The final step is to select the program that you want to perform The programs available are only those compatible with your previous selection In this example there are three available programs...

Страница 14: ...the Fast Buttons to continue 3 Simple step by step instructions will guide you through the program Each plate position is colour coded Red blue yellow and green go into the ROTOR Turntable while black...

Страница 15: ...he ROTOR HDA will now count the number of Pin Pads loaded to ensure there are enough to complete the program The ROTOR HDA will now start pinning the colonies for replication Live program information...

Страница 16: ...than 4 replicates of a target plate you can repeat the program with one click Make your selection When pinning is completed you will be instructed to remove the Plates Press OK when you are done A Pro...

Страница 17: ...Hopper from the Home Screen Rotate This rotates the Turntable Reset This resets the ROTOR HDA Load Plate Remove Plate Swap Plates UV This opens the UV Lamp Options Info This opens the Info and Settin...

Страница 18: ...y removed when it is vital to do so This will increase the time it takes to run each program but each source plate will be exposed for less time and the print head will never move over a source plate...

Страница 19: ...lates The retraction distance applied to the Pad Head after sensing the bottom of the plate The number of times each source pin ning will repeat Skipping around on the agar surface to select from a wi...

Страница 20: ...for each source pinning This feature is useful when pinning from source plates that have been printed to a non central location The pressure that the Pad Head will use to push onto the agar The speed...

Страница 21: ...he diameter from the specified diameter uniformly with each cycle for a thorough mix The number of cycles comprising of 5 steps that the dry mix on source plates will be executed Liquid mixing can be...

Страница 22: ...linear encoder Y Z are open loop stepper motor drives with optical data setting Pad Head Vacuum operated and fully floating to comply with agar surface Programmable variable pressure Pad Dispenser Ho...

Страница 23: ...lst replication is in progress This makes the process very continuous Performance tests carried out for Singer by a major yeast laboratory claim replication rates in excess of 100 PlusPlates per hour...

Страница 24: ...ed onto 1x 384 density plate 1 2 Pinning examples 1 4 Array 1 4 Single source 1 4 single source Each colony from a 1x 96 density plate replicated in quadruplicate to a 1x 384 density plate These proto...

Страница 25: ...HDA Success Time to enjoy your Delicious Beer you ve earned it Repeat steps 1 6 until suitably relaxed Place the Bottle Cap in the Bin Nobody likes a litter bug Lever the Beer Bottle to remove the Bot...

Страница 26: ...26 Notes...

Страница 27: ...27 singerinstruments com Notes...

Страница 28: ...28 Notes...

Страница 29: ...29 singerinstruments com Notes...

Страница 30: ...Roadwater Watchet Somerset TA23 0RE UK 44 0 1984 640226 tel 44 0 1984 641166 fax contact singerinstruments com singerinstruments com Scan to visit website for more helpful tips and tutorials...

Отзывы: