background image

Setting up the ACU-1 from the Front Panel

Replybyte1:
Bit0

Silence Alarm Left Channel is active

Bit1

Silence Alarm Right Channel is active

Bit2

Silence Detect Left Channel is active

Bit3

Silence Detect Right Channel is active

ReadPo

Function:

Reads the current relay settings.

Format:

AAhex/boxnode/3Ehex

—replybyte1

Bits set in replybyte1 correspond to relays on.  Bit 0 is relay 1.

SetLink

Function:

Sets linking for silence sense.

Format:

AAhex/boxnode/3Fhex/byte4

Byte4:
0

silence detect off

1

left and right separate

2

left or right linked

3

left and right linked

FadeUpDown

Function:

Turn one or more audio channels on and off.  

Format:

AAhex/boxnode/51hex/byte4/byte5

Set bits in byte4 to turn channel(s) on.  Set bits in  byte5 to turn channel(s) off.  Bit 0 is channel 1.  If common
bits are set in byte4 and byte5, the byte5 (fade down) bits override.

PoMomen

Function:

Operate relays momentarily

Format:

AAhex/boxnode/52hex/byte4

Bits set in byte4 will cause momentary relay operation.  Bit0 corresponds to relay 1.  Any combination of relays
may be operated momentarily at the same  time.  Relays that were previously turned on and are operated
momentarily will turn off after the delay period (delay period defined in SetPoTime).

SetNode

Function:

Set/read node address.

Format:

AAhex/boxnode/53hex/byte4

byte4:
0

read only

1-10

set node address

11-255

read only

SetBaud

Function:

Set baud rate.

Format:

AAhex/boxnode/54hex/byte4

ACU-1

page 6

Содержание ACU-1

Страница 1: ...g buttons 1 and 8 simultaneously for at least one second Program User Settings from the Front Panel firmware version 6 and later All user programming in the ACU 1 can be read and altered from the fron...

Страница 2: ...001000 Baud Rate 18 00010010 00000111 Momentary Relay Time 19 00010011 00110010 Left Silence Threshold 20 00010100 00000001 Right Silence Threshold 21 00010101 00000001 Left Silence Alarm Time 22 0001...

Страница 3: ...rom 0 to 255 where 255 is full on SetUp Function Sets fade up rate Format AAhex boxnode 34hex byte4 byte5 Byte4 determines the channel s which are to be set bit 0 being channel 1 byte5 sets the fade u...

Страница 4: ...channels Byte5 sets time 1 to 250 sets 1 to 250 seconds SetPo Function Sets parallel output Format AAhex boxnode 38hex byte4 Bits set in byte4 turn relays on Bit 0 is relay 1 ReadPi Function Reads th...

Страница 5: ...0 seconds Silence Level Left 42 dB Silence Level Right 42 dB Silence Time Left 30 seconds Silence Time Right 30 seconds Silence Link 1 L and R separate Automatic Level Control On 5 sec dB increase spe...

Страница 6: ...nels on and off Format AAhex boxnode 51hex byte4 byte5 Set bits in byte4 to turn channel s on Set bits in byte5 to turn channel s off Bit 0 is channel 1 If common bits are set in byte4 and byte5 the b...

Страница 7: ...de 56hex replybyte1 replybyte2 replybyte3 replybyte4 Replybyte1 replybyte2 and replybytebyte3 are hours minutes and seconds Replybyte4 0 24 hour time 1 AM 12 hour time 2 PM 12 hour time 3 clock not se...

Страница 8: ...ed Format AAhex boxnode 5Bhex byte4 Byte4 0 read ALC mode value returned in replybyte1 1 set ALC off 2 255 set ALC on 2 to 255 seconds per 1 dB gain increase SetPiHold Function Set read parallel input...

Страница 9: ...4 Byte4 b0 data mode 0 1 8E1 8N1 b1 ALC attack speed 0 1 normal slow firmware version 6 and later b2 unused b3 unused b4 unused b5 unused b6 unused b7 unused ReadConfig2 Function Read Config2 byte For...

Страница 10: ...Version 6 only Baud Rate Address decimal Address binary Data binary 115 2K 18 00010010 00000000 57 6K 18 00010010 00000001 38 4K 18 00010010 00010000 28 8K 18 00010010 00000010 19 2K 18 00010010 00010...