background image

1

7

Requirements for electric connection

Safety precaution

Grounding requirement

1. Must follow the electric safety regulations when installing the unit.

    air switch.

3. Make sure the power supply matches with the requirement of air conditioner.

    Unstable power supply or incorrect wiring or malfunction. Please install proper 

    power supply cables before using the air conditioner.

4. Properly connect the live wire, neutral wire and grounding wire of power socket.

5. Be sure to cut off the power supply before proceeding any work related to 

    electricity and safety.

7. If the supply cord is damaged, it must be replaced by the manufacturer, its 

8. The temperature of refrigerant circuit will be high, please keep the interconnec-

    tion cable away from the copper tube.

9. The appliance shall be installed in accordance with national wiring regulations.

    grounding with specialized grounding device by a professional. Please make 

    sure it is always grounded effectively, otherwise it may cause electric shock.

2. The yellow-green wire in air conditioner is grounding wire, which can't be used 

    for other purposes.

3. The grounding resistance should comply with national electric safety regulations.

4. The appliance must be positioned so that the plug is accessible.

5. An all-pole disconnection switch having a contact separation of at least 3mm in 

6. Including an air switch with suitable capacity, please note the following table. Air 

    switch should be included magnet buckle and heating buckle function, it can 

    protect the circuit-short and overload. (Caution: please do not use the fuse only 

    for protect the circuit)

Содержание SYMPHONY MS-H09AISW PT

Страница 1: ...USER S MANUAL MS H09AISW MS H12AISW MULTI SYSTEM SYMPHONY...

Страница 2: ...Original instructions...

Страница 3: ...tainable reuse of mate rial resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for env...

Страница 4: ...Please contact dealer when you need to repair air conditioner Do not block air inlet It may cause malfunction person can perform the work Otherwise it may cause personal injury or damage injury or da...

Страница 5: ...tual products Display content or position may be different from above graphics please refer to actual products Indoor Unit remote controller air inlet panel horizontal louver air outlet heating indica...

Страница 6: ...on Set temperature Set time X FAN function TIMER ON TIMER OFF Child lock Up down swing Left right swing Set fan speed Light Temp display type Set temp Outdoor ambient temp Indoor ambient temp Sleep mo...

Страница 7: ...peration mode in accordance with the room temperature to make indoor room comfortable As for cooling only unit it won t have any action when it receives the signal of heating operation This button is...

Страница 8: ...last setting sleep curve and blink display temperature display will resume to original setting temperature Sleep3 the sleep curve setting under Sleep mode by DIY could be inquired The user could acco...

Страница 9: ...tting press TIMER ON button to confirm will be constantly displayed Press T OFF button to initiate the auto off timer To cancel the auto timer program simply press the button again TIMER OFF setting i...

Страница 10: ...three times At unit OFF press MODE and buttons simultaneously to switch between and Combination of and buttons About lock About Back lighting Function Combination of MODE and buttons About switch bet...

Страница 11: ...an and Maintenance Note Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not wash the air conditioner with water to avoid electric s...

Страница 12: ...Open panel Pull out the panel to a certain Use dust catcher or water to the water below 45 to clean it and then put it in a shady and cool place to dry panel cover tightly Note operation environment c...

Страница 13: ...roded If yes please contact dealer 5 Check whether drainage pipe is damaged 1 Disconnect power supply 2 Clean filter and indoor unit s panel 3 Check whether mounting bracket for outdoor unit is damage...

Страница 14: ...oom Pull out the plug Reinsert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re cei...

Страница 15: ...r temperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set temp...

Страница 16: ...n the unit again Outdoor unit has vapor Heating mode is turned on During defrosting under he ating mode it may generate vapor which is a normal phenomenon Water noise Air conditioner is turned on or t...

Страница 17: ...ation of error code Above indicator diagram is only for reference Please refer to actual product for the actual indicator and position When below phenomenon occurs please turn off air conditioner and...

Страница 18: ...15 Installation dimension diagram At least 250cm At least 15cm At least 300cm Space to the ceiling Space to the obstruction At least 15cm At least 15cm Space to the wall Space to the wall...

Страница 19: ...be installed 2 5m 7 Don t install the indoor unit right above the electric appliance Indoor unit 1 The place with strong heat sources 8 Please try your best to keep way from fluorescent lamp or volat...

Страница 20: ...e keep the interconnec tion cable away from the copper tube 9 The appliance shall be installed in accordance with national wiring regulations grounding with specialized grounding device by a professio...

Страница 21: ...le should be a little lower than the wall mounted frame shown as below Step three open piping hole 2 Open a piping hole with the diameter of 55 on the selected outlet pipe position In order to drain s...

Страница 22: ...ing out the pipe from left or right please cut off the corresponding hole on the bottom case cut off the hole left right 1 The pipe can be led out in the direction of right rear right left or rear lef...

Страница 23: ...screw on the wiring cover and then take Step seven connect wire of indoor unit 4 Wrap the indoor pipe and joint of con then wrap it with tape Step six install drain hose Installation of indoor unit to...

Страница 24: ...parting and the contact parting distance should be more than 3mm 3 Remove the wire clip connect the power connection wire to the wiring terminal according to the color tighten the screw with wire clip...

Страница 25: ...parately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom drain hose band connection pipe indoor power cord Step nine hang the i...

Страница 26: ...unit grounded securely It may cause electric leakage Does the power cord follow the speci fication It may cause malfunction or damaging the parts Is there any obstruction in the air inlet and outlet I...

Страница 27: ...length of liquid pipe The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Additional refrigerant charging amount prolong...

Страница 28: ...r of connection pipe Liquid pipe mm Gas pipe mm 6 6 or 9 52 9 52 or 12 12 16 19 22 2 16 or 19 19 or 22 2 25 4 or 31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350 120 120 5...

Страница 29: ......

Страница 30: ...ble natural resources and help in preventing potential negative impacts to environment and human health which could be consequence of incorrect disposal of waste Ask for more details from local author...