background image

24

Table 4 Meaning of Each Error

Error

Code

Error 

Error

Error 

Code 

F1

Drive board communication error

P6

F2

Compressor overheating protection

H3

Return  air  temperature  sensor  open/short 

circuited

b5

Indoor and outdoor units unmatched

LP

evaporator temperature sensor  open/short 

circuited

b7

dn

IPM temperature sensor open/short circuited

P7

Indoor unit liquid valve temperature sensor 

open/short circuited

E7

F3

Fo

Pump-down 

F4

Indoor gas valve temperature sensor open/

short circuited

Defrost or oil return 

Outdoor unit condenser mid-tube temperature 

sensor open/short circuited

Communication  line  misconnected  or 

expansion valve error

F5

Forced defrosting

H1

Indoor and outdoor communication error

E6

Compressor startup failure

Lc

DC bus under-voltage protection

PL

High discharge temperature protection

E4

DC bus over-voltage protection

PH Overload protection

E8

Outdoor ambient temperature sensor open/

short circuited

U1

Whole unit over-current protection

E5

Compressor demagnetization protection

HE Over phase current protection

P5

PFC protection

Hc

Compressor desynchronizing

H7

P8

IPM Current protection

H5

Over-power protection

L9

IPM Temperature Protection

Discharge  temperature  sensor  open/short 

circuited

Ld

F0

F8

Capacitor charging error

PU

Compressor  phase  current  sensing  circuit 

error

Frequency restricted/reduced with whole 

unit current protection

Compressor  phase  lo ss/reversal 

protection

En

High pressure protection

E1

System  charge  shortage  or  blockage 

protection

F9

Low pressure protection

E3

Frequency restricted/reduced with IPM 

current protection

FH

Compressor stalling

LE

Frequency restricted/reduced with high 

discharge temperature

F6

Over-speeding

LF

dc

U0

Frequency restricted/reduced with anti-

freezing protection

EU

Drive board temperature sensor error

PF

Indoor unit full water error

E9

AC contactor protection

P9

Anti-freezing protection

E2

PE

Temperature drift protection

AC input voltage abnormal

PP

Sensor connection protection

Pd

Whole unit current sensing circuit error

U5

DC bus voltage drop error

U3

4-way valve reversing error

U7

Outdoor fan 1 error protection

L3

Motor stalling

Indoor fan tripping error

H6

Outdoor fan 2 error protection

Frequency  restricted/reduced  with 

overload protection

LA

PG motor zero-crossing protection

U8

Frequency restricted/reduced with IPM 

temperature protection

compressor inhalation temperature sensor error

Wired Controller 

SWC-04

Содержание SWC-04

Страница 1: ... Ver WIRED CONTROLLER SWC 04 EN User Manual 01 19 07 2021 ...

Страница 2: ... R I G I N A L I N S T R U C T I O N S I M P O R TA N T N O T E Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference ...

Страница 3: ...esen Link ein Termék kézikönyvének letöltéséhez írja be a modell megnevezését az alábbi linkre Za prenos navodil za uporabo tega izdelka vnesite ime modela na tej po vezavi Per scaricare il manuale di questo pro dotto inserisci il nome del modello a questo link Чтобы загрузить руководство для этогопродукта введитеобозначение модели по следующей ссылке Para descargar el manual de este pro ducto ing...

Страница 4: ...ose set temperature is adjustable under auto mode the wired controller will receive the mode signal of remote controller rather than its set temperature under the auto mode The wired controller is the universal component When indoor unit has connected with the wired controller display status of indoor unit is decided by the indoor unit Valid status and invalid status are all belong to normal statu...

Страница 5: ...tting 7 3 6 Up Down Swing Setting 6 3 15 Health Setting 3 8 Fresh Air Function Setting 3 9 Sleep Setting 3 10 Turbo Setting 3 11 Energy Saving Function Setting 3 12 E heater Setting 3 13 X fan Setting 3 14 Quiet Function Setting 15 14 13 3 16 Absent Setting 16 12 11 9 8 10 3 18 WiFi Function Setting 18 3 17 I Demand Setting 17 3 19 Other Functions 18 4 1 Connection of the Signal Line of the Wired ...

Страница 6: ...ontroller SWC 04 1 Fig 2 LCD of the Wired Controller Fig 1 Outside View of the Wired Controller 1 2 LCD of the Wired Controller Wired Controller SWC 04 1 Symbols on LCD 1 1 Outside View of the Wired Controller ...

Страница 7: ...is set 15 Display when up and down swing function is set Slave wired controller 16 Fan speed 17 No card 18 No card in gate control system Left right swing 19 Display when left and right swing function is set Icon of slave wired controller it will display when slave wired controller is set this function is unavailable for this unit X fan The fan speed set currently including auto low medium low med...

Страница 8: ...e 04 is displayed on the timer display area By pressing them at the same time under off state of the unit will be displayed on the wired controller for the cooling only unit while displayed on the wired controller for the cooling and heating unit Reset the WiFi function Under off status press FUNCTION FAN combination buttons on its wired controller for 5s Once oC is displayed this indicates that r...

Страница 9: ...nge is 16 C 30 C 61 F 86 F In the Auto mode the setting temperature is unadjustable Wi Fi Under the ON state of the unit press MODE to switch the operation modes as the following sequence Auto Cooling Dry Fan Heating Note The state shown in Fig 4 indicates the OFF state of the unit after power on The state shown in Fig 5 indicates the ON state of the unit after power on Wi Fi Note If the wired con...

Страница 10: ...mer on setting press Timer and then LCD will display xx x hour with hour blinking In this Under the ON State of the unit press Fan and then fan speed of the indoor unit will change circularly as shown in Fig 7 Timer off setting press Timer if LCD won t display xx x hour and then it means the timer setting is canceled Auto High Low Medium low Medium Medium high SWING ENTER Wired Controller SWC 04 ...

Страница 11: ...de is turned off When it is set to be fixed swing press SWING ENTER button the unit will circularly switch the swing mode according to the order shown below There are two ways for up and down swing mode simple swing and fixed swing Under off status press SWING ENTER button and button simultaneously for 5 seconds then switch for simple swing and fixed swing is done Timer range 0 5 24hr Every press ...

Страница 12: ...s function Press SWING ENTER button to cancel swing Swing On Press FUNCTION under on state of the unit to activate the swing function In this case will blink After that press SWING ENTER to make a confirmation Swing Off When the Swing function is on press FUNCTION to enter the Swing setting interface Sleep Turbo or X fan setting is the same as the Swing setting After the setting has been done it h...

Страница 13: ...resh air valve setting mode Previous temperature display position will display the level of fresh air valve Press or button to adjust the level of fresh air valve within the range from 1 to 10 Then press SWING ENTER button to activate this function valve function option When icon flashes if you press SWING ENTER button without pressing or button fresh air valve function will be canceled if you pre...

Страница 14: ...ENTER button to cancel sleep Press SWING ENTER button to turn on sleep Sleep off When the Sleep function is activated press FUNCTION to enter the Sleep setting interface After that press SWING ENTER to can this function Sleep on Press FUNCTION under on state of the unit till the unit enters the Sleep setting interface Press SWING ENTER to confirm the setting Wired Controller SWC 04 ...

Страница 15: ...e quick cooling or heating so that the room temperature can quickly approach the setting value In the Cooling or Heating mode press FUNCTION till the unit enters the Turbo setting interface Press SWING ENTER to turn on turbo function When the Turbo function is activated press FUNCTION to enter the Turbo setting interface and then press SWING ENTER to cancel this function Press SWING ENTER to turn ...

Страница 16: ...energy saving function will be canceled if you press SWING ENTER button after pressing or button energy saving function will be activated When the unit runs under the HEAT mode press FUNCTION button to select SAVE function option with SAVE flashing and then press or to adjust the upper limit after that press SWING ENTER button to activate this function Note under energy saving setting mode press M...

Страница 17: ...eating mode E heater is allowed to be Once the wired controller or the remote controller enters the Heating mode this function turned on automatically Wi Fi Press FUNCTION in the Heating mode to enter the E heater setting interface and then press SWING ENTER to cancel this function Wi Fi Wi Fi Press FUNCTION button into this function Press FUNCTION button into auxiliary electric heating function W...

Страница 18: ...tically evaporated to avoid mildew In the Cooling or Dry mode press FUNCTION till the unit enters the X fan setting interface and then press SWING ENTER to active this function When the X fan function is activated press FUNCTION to the X fan setting interface and then press SWING ENTER to cancel this function When the X fan function is activated if turning off the unit by pressing ON OFF or by the...

Страница 19: ...ion If quiet function has been set press FUNCTION button on the panel to select Quiet function option Wi Fi When Quiet or Auto quiet flashes if you press SWING ENTER button without pressing or button quiet function will be canceled if you press SWING ENTER button after pressing or button quiet function will be activated Wi Fi Press FUNCTION button to select the Quiet function option Turn on the un...

Страница 20: ...unction is activated press FUNCTION to enter the Health setting interface After that press SWING ENTER to cancel this function Wi Fi Wi Fi Wi Fi Wi Fi Wi Fi Press FUNCTION button into health state Turn on the unit without turning on health function Press FUNCTION button into health state Press SWING ENTER button to turn off health function Press SWING ENTER button to turn on health function Wired ...

Страница 21: ...NG ENTER to confirm the setting 2 setting and fan speed setting are shielded 3 4 This function will be cancelled when switching modes When this function has been set set temperature is displayed in 8 C 46 F In this case temperature Fig 18 Absent Setting This function and sleep function cannot be on simultaneously If Absent function is set firstly and then sleep quiet function is set Absent functio...

Страница 22: ...d function 1 This function is only available in cooling mode 2 and fan speed setting are shielded When this function has been set set temperature is displayed in SE In this case temperature setting 3 This function will be cancelled when switching modes 4 This function and sleep function cannot be on simultaneously If I demand function is set firstly and then sleep quiet function is set I demand fu...

Страница 23: ...nder on state of the unit till the unit enters the WiFi setting interface the temperature area will display the WiFi status Press or button to turn on WiFi ON is displayed or turn off WiFi OFF is displayed and then press SWING ENTER button to confirm it Note factory setting Under off status press FUNCTION FAN combination buttons on its wired controller for 5s Once oC is displayed this indicates th...

Страница 24: ...tric control box of the indoor unit Let the single line of the wired controller through the soleplate of wired controller Connect the signal line of the wired controller to the 4 pin socket of the indoor unit The communication distance between the main board and the wired controller can Under the commissioning status if there is no any operation in 20 seconds after the last button press it will ba...

Страница 25: ...dle stand s basing on the requirement Fig 21 shows the installation steps of the wired controller but there are some issues that need your attention 1 Prior to the installation please firstly cut off the power supply of the wire buried in the installation hole that is no operation is allowed with electricity during the whole installation 2 Pull out the four core twisted pair line from the installa...

Страница 26: ...3 Schematic diagram of connection wire Connect terminal with wired terminal of patch cord at first connect the connection wire with the patch cord according to fig 25 and then insert the terminal of connection wire into the needle stand CN1 of wired controller and insert the terminal of patch cord into the terminal of wired controller of air conditioner as well controller CN1 connect terminal with...

Страница 27: ...tem connection SWC 04 can connect the smart zone controller integrated control system n indicates the number of communication node address programmable wired controller SWC 04 The complete system is composed of the smart zone controller wired controller SWC 04 and communication cable The wired controller SWC 04 can support 16 communication node addresses at the most n 16 Terminal A and terminal B ...

Страница 28: ...to electromagnetic interference 4 3 Dismantlement of the Wired Controller then the signal and communication lines of the wired controller must be the shielding twisted pair lines If there is an error occurring during the operation of the system the error code will be displayed on the LCD as show in Fig 28 If multi errors occur at the same time their codes will be displayed circularly Note In event...

Страница 29: ...rotection H5 Over power protection L9 IPM Temperature Protection Discharge temperature sensor open short circuited Ld F0 F8 Capacitor charging error PU Compressor phase current sensing circuit error Frequency restricted reduced with whole unit current protection Compressor phase loss reversal protection En High pressure protection E1 System charge shortage or blockage protection F9 Low pressure pr...

Страница 30: ...Error Error Code Communication error between IDU and grid connection Communication error between ODU and grid connection Ln LM y2 y3 Main error at grid connection side yb IDU network address error Ip address allocation overflow Wired Controller SWC 04 ...

Страница 31: ...n W1F 7LD Great Britain www sinclair world com This product was manufactured in China Made in China R E P R E S E N TAT I V E SINCLAIR Global Group s r o Purkynova 45 612 00 Brno Czech Republic T E C H N I C A L S U P P O R T SINCLAIR Global Group s r o Purkynova 45 612 00 Brno Czech Republic Tel 420 800 100 285 Fax 420 541 590 124 www sinclair solutions com info sinclair solutions com I N F O R M...

Страница 32: ...N O T E S ...

Страница 33: ...N O T E S ...

Страница 34: ...N O T E S ...

Страница 35: ...esen Link ein Termék kézikönyvének letöltéséhez írja be a modell megnevezését az alábbi linkre Za prenos navodil za uporabo tega izdelka vnesite ime modela na tej po vezavi Per scaricare il manuale di questo pro dotto inserisci il nome del modello a questo link Чтобы загрузить руководство для этогопродукта введитеобозначение модели по следующей ссылке Para descargar el manual de este pro ducto ing...

Страница 36: ...66139901148 ...

Отзывы: