Sinclair SDV5-22HA Скачать руководство пользователя страница 30

No

Description 

Part Code 

Note

Qty  Price Code 

1

Panel

12122000A02212

1

2

Panel frame assembly

12122000001983

1

3

Horizontal louver assembly

12122000005101

1

4

Evaporator assembly

15826000002333

1

4.1

Pipr temp sensor assembly

11201007003022

1

4.2

Evaporator input pipe ass'y

15426000000476

1

4.3

Evaporator output pipe ass'y

15126000001231

1

4.4

Evaporator

15826000000359

1

4.5

Evaporator

15826000000358

1

4.6

Evaporator

15826000000357

1

5

VRF IDU display box assembly

17226000002938

1

6

Brushless DC Motor

11002015000248

1

7

Butting Connector

11201707000001

3

8

Cover of electronic control box

12122000004994

1

9

E-part box assembly

17226000002835

1

9.1

Electronic control box

12122000004565

1

9.2

Indoor unit main control board

17126000003568

1

10

Electronic control box

12122000004586

1

11

Air freshening filter

12100204000685

1

11

Air filter

12100204000626

2

12

Installation plate

12222000000012

1

13

Chassis assembly

12122000009005

1

13.1

Stepper motor

11002010000143

1

14

Bearing

12122000007617

1

15

Bearing base

12622000000006

1

16

Bearing holder

12122000000350

1

17

Cross flow fan

12100102000074

1

18

Temp. sensor fixed card

12100303000128

1

19

Drainage plug

12600801000081

1

20

Motor cover ass'y

12126000000283

1

21

pipe clamp board

12122000000445

1

22

Electrical appliance box

12126000001743

1

24

E-Part box fire-proof plate

12226000003840

1

27

Temperature sensor

11201007000879

1

27

Pipe temperature sensor

11201007000102

1

28

Drain hose

12100501000004

1

29

Copper nut

15500406000012

1

30

Drain pipe

12126000000144

1

MODEL: SDV5-28HA WALL-MOUNTED UNIT

The data are subject to change without notice.

Содержание SDV5-22HA

Страница 1: ...INDOOR WALL MOUNTED UNITS SDV5 XXHA C O M M E R C I A L A I R C O N D I T I O N E R S S D V 5...

Страница 2: ...Original instructions IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference...

Страница 3: ...3 1 Specifications 4 2 Dimensions 6 3 Unit Placement 7 4 Piping Diagram 8 5 Wiring Diagram 9 6 Capacity Tables 12 7 Electrical Characteristics 20 8 Sound Levels 21...

Страница 4: ...31 31 30 30 35 34 33 33 32 31 31 Sound power level dB A 46 45 45 45 44 44 44 46 45 45 45 44 44 44 48 47 47 46 46 45 45 50 49 48 48 47 46 46 Unit Net dimensions 5 WxHxD mm 835 280 203 990 315 223 Pack...

Страница 5: ...39 38 3 7 36 48 46 45 43 41 4 0 38 Sound power level dB A 53 52 51 51 50 4 9 49 59 58 57 54 53 5 2 51 59 58 57 54 53 5 2 51 63 61 60 58 56 5 5 53 Unit Net dimensions 5 WxHxD mm 990 315 223 1194 343 2...

Страница 6: ...6 2 Dimensions 2 1 Unit Dimensions Figure 2 1 Wall mounted dimensions unit mm SDV5 22HA SDV5 28HA SDV5 36HA SDV5 45HA SDV5 56HA SDV5 71HA SDV5 80HA SDV5 90HA...

Страница 7: ...midity may occur such as a laundry Units should be installed in positions where The ceiling is horizontal and is able to bear the unit s weight There are no obstructions that could impede the airflow...

Страница 8: ...iping diagram flare nut flare nut T2B gas side motor heat exchanger fan EXV liquid side T2 T1 Legend T1 Indoor ambient temperature sensor T2 Indoor heat exchanger mid point temperature sensor T2B Indo...

Страница 9: ...wing motor Electronic expansion valve Room temp sensor Mid pipe temp sensor Outlet pipe temp sensor Water level switch Connectors nted wiring diag gram CN7 CN30 CN22 CN21 ENC1 CN13 CN4 CN300 CN1 CN2 C...

Страница 10: ...alve Room temp sensor Mid pipe temp sensor Outlet pipe temp sensor Water level switch Connectors mounted wiring CN12 CN5 CN7 CN30 ON SW1 ON SW2 ENC1 ON SW3 CN20 diagram 1 2 1 2 1 2 1 2 ON SW4 1 2 ON S...

Страница 11: ...rvice eng g diagram CN9 1 2 ON SW1 CN17 CN11 SW8 CN18 C N 1 1 N 1 6 CN13 ntenance mu n accordance dance with a with all appli curely fasten ntenance the or electric sh y setting is f witch ENC1 m re t...

Страница 12: ...1 5 1 3 1 8 1 4 2 1 1 5 2 2 1 5 2 2 1 5 2 3 1 3 2 3 1 4 44 0 1 5 1 3 1 8 1 4 2 1 1 5 2 2 1 5 2 2 1 5 2 3 1 3 2 3 1 4 46 0 1 5 1 3 1 8 1 4 2 1 1 5 2 2 1 5 2 2 1 5 2 3 1 3 2 3 1 4 2 8 10 0 1 9 1 6 2 3...

Страница 13: ...4 2 3 3 6 2 4 3 7 2 4 3 8 2 3 3 8 2 1 44 0 2 5 1 9 2 9 2 1 3 4 2 3 3 6 2 4 3 7 2 4 3 8 2 3 3 8 2 1 46 0 2 5 1 9 2 9 2 1 3 4 2 3 3 6 2 4 3 7 2 4 3 8 2 3 3 8 2 1 4 5 10 0 3 1 2 4 3 7 2 6 4 2 2 8 4 5 2...

Страница 14: ...3 3 3 5 6 3 4 5 7 3 4 5 8 3 2 6 0 3 1 44 0 3 9 2 7 4 6 3 0 5 3 3 3 5 6 3 4 5 7 3 4 5 8 3 2 6 0 3 1 46 0 3 9 2 7 4 6 3 0 5 3 3 3 5 6 3 4 5 7 3 7 5 8 3 2 6 0 3 1 7 1 10 0 4 9 3 6 5 8 4 0 6 7 4 3 7 1 4...

Страница 15: ...4 9 7 5 5 3 8 0 5 5 8 1 5 3 8 3 5 0 8 6 4 9 44 0 5 5 4 4 6 6 4 9 7 5 5 3 8 0 5 5 8 1 5 3 8 3 5 0 8 6 4 9 46 0 5 5 4 4 6 6 4 9 7 5 5 3 8 0 5 5 8 1 5 3 8 3 5 0 8 6 4 9 9 0 10 0 6 2 4 9 7 3 5 3 8 4 5 8 9...

Страница 16: ...40 2 33 2 21 2 02 9 80 11 00 2 54 2 54 2 40 2 33 2 21 2 02 11 80 13 00 2 64 2 59 2 40 2 33 2 21 2 02 13 70 15 00 2 71 2 59 2 40 2 33 2 21 2 02 2 8 20 19 8 1 79 1 79 1 79 1 79 1 79 1 79 19 18 8 1 92 1...

Страница 17: ...3 68 3 36 9 80 11 00 4 24 4 24 4 00 3 88 3 68 3 36 11 80 13 00 4 40 4 32 4 00 3 88 3 68 3 36 13 70 15 00 4 52 4 32 4 00 3 88 3 68 3 36 4 5 20 19 8 2 80 2 80 2 80 2 80 2 80 2 80 19 18 8 3 00 3 00 3 00...

Страница 18: ...5 80 5 29 9 80 11 00 6 68 6 68 6 30 6 11 5 80 5 29 11 80 13 00 6 93 6 80 6 30 6 11 5 80 5 29 13 70 15 00 7 12 6 80 6 30 6 11 5 80 5 29 7 1 20 19 8 4 48 4 48 4 48 4 48 4 48 4 48 19 18 8 4 80 4 80 4 80...

Страница 19: ...0 8 73 8 28 7 56 9 80 11 00 9 54 9 54 9 00 8 73 8 28 7 56 11 80 13 00 9 90 9 72 9 00 8 73 8 28 7 56 13 70 15 00 10 17 9 72 9 00 8 73 8 28 7 56 9 0 20 19 8 5 60 5 04 5 60 5 60 5 60 5 60 19 18 8 6 00 5...

Страница 20: ...02 0 25 SDV5 28HA 50 220 240 198 264 0 32 15 0 02 0 25 SDV5 36HA 50 220 240 198 264 0 45 15 0 058 0 36 SDV5 45HA 50 220 240 198 264 0 47 15 0 058 0 37 SDV5 56HA 50 220 240 198 264 0 58 15 0 058 0 46...

Страница 21: ...in situ operation sound pressure levels may be higher as a result of ambient noise Figure 8 1 Wall mounted sound pressure level measurement 8 2 Octave Band Levels Figure 8 2 SDV5 22 28HA octave band...

Страница 22: ...enter frequency Hz Octave band center frequency Hz 0 10 20 30 40 50 60 70 80 63 125 250 500 1000 2000 4000 8000 0 10 20 30 40 50 60 70 80 63 125 250 500 1000 2000 4000 8000 0 10 20 30 40 50 60 70 80 6...

Страница 23: ...SDV5 22 28HA Exploded View...

Страница 24: ...SDV5 36 45HA Exploded View...

Страница 25: ...SDV5 71 80 90HA Exploded View...

Страница 26: ...WALL MOUNTED UNITS SDV5 22 90HA C O M M E R C I A L A I R C O N D I T I O N E R S S D V 5...

Страница 27: ...SDV5 22HA...

Страница 28: ...00003568 1 10 Electronic control box 12122000004586 1 11 Air freshening filter 12100204000685 1 11 Air filter 12100204000626 2 12 Installation plate 12222000000012 1 13 Chassis assembly 12122000009005...

Страница 29: ...SDV5 28HA...

Страница 30: ...r unit main control board 17126000003568 1 10 Electronic control box 12122000004586 1 11 Air freshening filter 12100204000685 1 11 Air filter 12100204000626 2 12 Installation plate 12222000000012 1 13...

Страница 31: ...SDV5 36HA...

Страница 32: ...6 1 8 6 Fire proof Plate of Electrical Control Box CoverBox 12222000000419 1 8 7 Fire proof Plate of Electrical Control Box CoverBox 12222000000391 1 8 8 Electric control box cover assembly 1222600000...

Страница 33: ...SDV5 45HA...

Страница 34: ...re joint 17400401002576 1 8 6 Fire proof Plate of Electrical Control Box CoverBox 12222000000419 1 8 7 Fire proof Plate of Electrical Control Box CoverBox 12222000000391 1 8 8 Electric control box cov...

Страница 35: ...SDV5 56HA...

Страница 36: ...oint 17400401002576 1 8 6 Fire proof Plate of Electrical Control Box CoverBox 12222000000419 1 8 7 Fire proof Plate of Electrical Control Box CoverBox 12222000000391 1 8 8 Electric control box cover a...

Страница 37: ...SDV5 71HA...

Страница 38: ...inal 17400401000020 1 9 5 Wire joint 17400401001516 1 9 6 Fire proof Plate of Electrical Control Box CoverBox 12222000000380 1 10 Chassis assembly 12122000004184 1 11 VRF IDU display box assembly 1722...

Страница 39: ...SDV5 80HA...

Страница 40: ...inal 17400401000020 1 9 5 Wire joint 17400401001516 1 9 6 Fire proof Plate of Electrical Control Box CoverBox 12222000000380 1 10 Chassis assembly 12122000004184 1 11 VRF IDU display box assembly 1722...

Страница 41: ...SDV5 90HA...

Страница 42: ...inal 17400401000020 1 9 5 Wire joint 17400401001516 1 9 6 Fire proof Plate of Electrical Control Box CoverBox 12222000000380 1 10 Chassis assembly 12122000004184 1 11 VRF IDU display box assembly 1722...

Страница 43: ...containing fluorinated gases included in the Kyoto protocol The maintenance and the liquidation must be carried out by qualified personnel Type of refrigerant R410A The composition of the cooling med...

Отзывы: