background image

When unit is turned off, mode, temperature, fan speed and swing can’t be

set.

(2) Mode setting

Press

 

the

 

Mode

 

buttons

 

to

 

set

 

 

UNI

 

SPLIT

 

unit

 

operation

 

mode.

 

Modes

 

for

 

indoor

 

units

 

of

 

different

 

series

 

are

 

not

 

all

 

the

 

same.If

 

a

 

certain

 

mode

 

is

 

not

 

available

 

in

 

the

 

indoor

 

unit,

 

the

 

icon

 

of

 

the

corresponding

 

mode

 

cannot

 

be

 

selected.

Note:

1)

 

Auto

 

mode

 

can

 

only

 

be

 

set

 

in

 

the

 

master

 

indoor

 

unit.

2)

 

Heat

 

recollection

 

system

 

have

 

no

 

master

 

indoor

 

unit.

 

When

 

the

 

indoor

 

unit

of

 

the

 

same

 

branch

 

is

 

connected

 

into

 

one

 

indoor

 

unit,

 

the

 

auto

 

mode

 

can

be

 

set;

 

when

 

the

 

quantity

 

of

 

indoor

 

unit

 

in

 

the

 

same

 

branch

 

is

 

more

 

than

one

 

set,

 

the

 

auto

 

mode

 

cannot

 

be

 

set;

 

other

 

modes

 

can

 

be

 

freely

switched.

(3) Temperature setting

Press the up or down buttons to adjust temperature. Each time pressing the

button will increase/decrease the temperature by 1. Holding down the button

can increase/decrease temperature continuously.

Pressing the

button can display the “indoor temp” and “outdoor temp”.

(4)

 

Fan

 

speed

 

setting

Press

 

the

 

fan

 

speed

 

button

 

to

 

set

 

 

UNI

 

SPLIT

 

unit

 

fan

 

speed.

Note:

 

Unit

 

defaults

 

to

 

low

 

fan

 

speed

 

in

 

drying

 

mode.

 

Fan

 

speed

 

cannot

 

be

 

set

in

 

drying

 

or

 

floor

 

heating

 

mode.

(5)

 

Swing

 

setting

Pressing

 

the

 

button

 

“Up&Down

 

Swing”

 

or

 

“Left&Right

 

Swing”

 

can

 

turn

 

on

 

or

off

 

the

 

swing

 

function.

Note:

 

Swing

 

types

 

for

 

indoor

 

units

 

of

 

different

 

series

 

are

 

not

 

all

 

the

 

same.

(6)

 

Malfunction

 

View

When indoor unit fails to function well, the will turn red. then press the button

to view the information of malfunctions.

5.4.3

Advanced Control Parameters

Press the advanced button to enter the advanced page.

Press the icons to turn on or off related functions.

Centralized Controller

Содержание SCC-36

Страница 1: ...CENTRAL CONTOLLER SCC 36 USER S MANUAL EN...

Страница 2: ...ion manual is a universal manual some functions are only applicable to particular product All the illustrations and information in the instruction manual are only for reference and control interface s...

Страница 3: ...above special places please adopt special product with anti corrosive or anti explosion function 2 User Notice 1 All indoor units must be supplied with unified power 2 Make sure communication cord is...

Страница 4: ...secure the rear cover of controller Rear cover of controller Rubber band QTY 1 4 1 6 No Name Screw M4 12 used to secure earthing wire Screw ST4 2 16 FA used to secure electric box cover Electric box c...

Страница 5: ...2 0 75 2 1 25 2 AW G18 2 A WG16 L 1000m L 3280 5 6feet If cord size is 2 1mm2 2 AWG16 communication cord can be stretched longer But the total length can t exceed 1500m 4921 1 4feet Outdoor network L...

Страница 6: ...re units might be splashed by water 3 2 Wiring Instructions 3 2 1 Wiring Ports Port print G1 G2 F1 F2 A2 B2 A3 B3 L N Meaning CAN comm port fire alarm port reserved port L CAC Split Unit port Power po...

Страница 7: ...l up to 36 UNI SPLIT units 2 If the centralized controller is to be connected with UNI SPLIT units connect according to fig 3 7 The controller must connect with terminal unit of UNI SPLIT system Conne...

Страница 8: ...ancel or Swing Enter to save the setting and exit Under the setting status if no action is taken within 20 seconds system will exit from the setting and return to the display mode of OFF status Settin...

Страница 9: ...r is to be connected with Wired Controller SWC 02 communication line one end is two core terminal the other end is the bare wire Code 420400060252 need to be purchased separately The quantity of commu...

Страница 10: ...P switch should be manually pulled to position on and position off respectively The DIP switches of other wired controllers should be kept at the initial ex factory status 1 bit and 2 bit are set at p...

Страница 11: ...e whole installation process 2 During the installation be careful not to damage to touch screen 3 Before installation please make the following preparations 1 In case that the centralized controller i...

Страница 12: ...on a safe place 5 In step connect the communication cords to A3 B3 terminals and connect the neutral wire and live wire to the N L terminal connect the ground wire to position on the electric box rea...

Страница 13: ...o page 3 Setting button Press this button to enter setting page 4 Single Control button Press this button to enter UNI SPLIT or MULTI VARIABLE unit page 5 Touch button Press the Touch Button to turn o...

Страница 14: ...ress this button to enter Group control page IDU Sort Press this button to enter IDU sort page Edit Press this button to edit the group or schedule Delete Press this button to delete group or schedule...

Страница 15: ...s 2 Icon Text According to the meaning of words turn on or off or select a certain function or enter a certain page This type of button has 2 or 3 kinds of status based on the specific function Meanin...

Страница 16: ...ning on off of corresponding function or the corresponding page will pop in Figure 4 2 Zone Buttons on the Homepage of Schedule 5 FUNCTIONS DESCRIPTION 5 1 Help Info On the homepage press to enter int...

Страница 17: ...or Down button to adjust temperature Press this button once to increase or decrease temperature 1 Press or hole this button and the temperature will increase or decrease continuously 4 Fan speed sett...

Страница 18: ...5 3 Schedule Management On the homepage press button to enter into the page of schedule management Figure 5 8 Page of Schedule Centralized Controller...

Страница 19: ...dule Press to enter the page of schedule editing Press to enter the page of schedule editing 1 Setting method of schedule control parameters is the same with that of the single indoor unit control 2 A...

Страница 20: ...tting page of schedule exception The calendar will pop in user can select the date to activate or cancel exception Press to save the selected date Notes When schedule exception has been set air condit...

Страница 21: ...running mode will be displayed in the following way auto cool dry fan heat 4 Icon of set temperature Display when the unit is ON It means set temperature of the device 5 Icon of malfunction If the un...

Страница 22: ...trol icon for 5S to enter the page of settings Then you may set the name and icon for the unit UNI SPLIT and MULTI VARIABLE unit control parameters include general control parameters and advanced cont...

Страница 23: ...buttons to adjust temperature Each time pressing the button will increase decrease the temperature by 1 Holding down the button can increase decrease temperature continuously Pressing the button can...

Страница 24: ...tatus 2 Absence function can only be enabled in Heat mode When Absence function is enabled set temperature is 8 3 When All Shield function is enabled other shield buttons are ineffective 5 5 Local Set...

Страница 25: ...t saving time DST 4 User password Press the button can activate or inactivate user password When password is activated it can be set or changed in 4 10 numbers or characters Original password is blank...

Страница 26: ...cons of indoor units and other relevant ex factory default settings 1 When switching between indoor network and outdoor network or reset unit IP restore the ex factory setting for centralized controll...

Страница 27: ......

Страница 28: ...are making an important contribution to the protection of our environment Please ask your local council where your nearest disposal station is located In case of quality problem or other please conta...

Отзывы: