background image

Figure 3-10 Diagram of Wooden or Plastic Plug

Figure 3-11 Installation Holes of the Electric Box Rear Cover

fig.3–9 is a simple installation procedure of centralized controller. Please pay

attention to the following matters:

(1) Before installation, first cut off the power supply of indoor unit. The power

must be cut off during the whole installation process.

(2) During the installation, be careful not to damage to touch screen.

(3) Before installation, please make the following preparations:

1) In case that the centralized controller is installed on wall, dig a hole that is

the size of 180mm×107mm×62mm and peg 4 wooden or plastic plugs on

the wall according to fig.3–10.

2) In case that the centralized controller is installed inside the control

cabinet, dig 4 installation holes on the surface of the control cabinet

according to fig.3–11.

Centralized Controller

Содержание SCC-36

Страница 1: ...CENTRAL CONTOLLER SCC 36 USER S MANUAL EN...

Страница 2: ...ion manual is a universal manual some functions are only applicable to particular product All the illustrations and information in the instruction manual are only for reference and control interface s...

Страница 3: ...above special places please adopt special product with anti corrosive or anti explosion function 2 User Notice 1 All indoor units must be supplied with unified power 2 Make sure communication cord is...

Страница 4: ...secure the rear cover of controller Rear cover of controller Rubber band QTY 1 4 1 6 No Name Screw M4 12 used to secure earthing wire Screw ST4 2 16 FA used to secure electric box cover Electric box c...

Страница 5: ...2 0 75 2 1 25 2 AW G18 2 A WG16 L 1000m L 3280 5 6feet If cord size is 2 1mm2 2 AWG16 communication cord can be stretched longer But the total length can t exceed 1500m 4921 1 4feet Outdoor network L...

Страница 6: ...re units might be splashed by water 3 2 Wiring Instructions 3 2 1 Wiring Ports Port print G1 G2 F1 F2 A2 B2 A3 B3 L N Meaning CAN comm port fire alarm port reserved port L CAC Split Unit port Power po...

Страница 7: ...l up to 36 UNI SPLIT units 2 If the centralized controller is to be connected with UNI SPLIT units connect according to fig 3 7 The controller must connect with terminal unit of UNI SPLIT system Conne...

Страница 8: ...ancel or Swing Enter to save the setting and exit Under the setting status if no action is taken within 20 seconds system will exit from the setting and return to the display mode of OFF status Settin...

Страница 9: ...r is to be connected with Wired Controller SWC 02 communication line one end is two core terminal the other end is the bare wire Code 420400060252 need to be purchased separately The quantity of commu...

Страница 10: ...P switch should be manually pulled to position on and position off respectively The DIP switches of other wired controllers should be kept at the initial ex factory status 1 bit and 2 bit are set at p...

Страница 11: ...e whole installation process 2 During the installation be careful not to damage to touch screen 3 Before installation please make the following preparations 1 In case that the centralized controller i...

Страница 12: ...on a safe place 5 In step connect the communication cords to A3 B3 terminals and connect the neutral wire and live wire to the N L terminal connect the ground wire to position on the electric box rea...

Страница 13: ...o page 3 Setting button Press this button to enter setting page 4 Single Control button Press this button to enter UNI SPLIT or MULTI VARIABLE unit page 5 Touch button Press the Touch Button to turn o...

Страница 14: ...ress this button to enter Group control page IDU Sort Press this button to enter IDU sort page Edit Press this button to edit the group or schedule Delete Press this button to delete group or schedule...

Страница 15: ...s 2 Icon Text According to the meaning of words turn on or off or select a certain function or enter a certain page This type of button has 2 or 3 kinds of status based on the specific function Meanin...

Страница 16: ...ning on off of corresponding function or the corresponding page will pop in Figure 4 2 Zone Buttons on the Homepage of Schedule 5 FUNCTIONS DESCRIPTION 5 1 Help Info On the homepage press to enter int...

Страница 17: ...or Down button to adjust temperature Press this button once to increase or decrease temperature 1 Press or hole this button and the temperature will increase or decrease continuously 4 Fan speed sett...

Страница 18: ...5 3 Schedule Management On the homepage press button to enter into the page of schedule management Figure 5 8 Page of Schedule Centralized Controller...

Страница 19: ...dule Press to enter the page of schedule editing Press to enter the page of schedule editing 1 Setting method of schedule control parameters is the same with that of the single indoor unit control 2 A...

Страница 20: ...tting page of schedule exception The calendar will pop in user can select the date to activate or cancel exception Press to save the selected date Notes When schedule exception has been set air condit...

Страница 21: ...running mode will be displayed in the following way auto cool dry fan heat 4 Icon of set temperature Display when the unit is ON It means set temperature of the device 5 Icon of malfunction If the un...

Страница 22: ...trol icon for 5S to enter the page of settings Then you may set the name and icon for the unit UNI SPLIT and MULTI VARIABLE unit control parameters include general control parameters and advanced cont...

Страница 23: ...buttons to adjust temperature Each time pressing the button will increase decrease the temperature by 1 Holding down the button can increase decrease temperature continuously Pressing the button can...

Страница 24: ...tatus 2 Absence function can only be enabled in Heat mode When Absence function is enabled set temperature is 8 3 When All Shield function is enabled other shield buttons are ineffective 5 5 Local Set...

Страница 25: ...t saving time DST 4 User password Press the button can activate or inactivate user password When password is activated it can be set or changed in 4 10 numbers or characters Original password is blank...

Страница 26: ...cons of indoor units and other relevant ex factory default settings 1 When switching between indoor network and outdoor network or reset unit IP restore the ex factory setting for centralized controll...

Страница 27: ......

Страница 28: ...are making an important contribution to the protection of our environment Please ask your local council where your nearest disposal station is located In case of quality problem or other please conta...

Отзывы: