Press this button to set clock time. "     " icon on remote controller will blink. Press 

"+" or "-" button within 5s to set clock time. Each pressing of "+" or "-" button, clock

time will increase or decrease 1 minute. If hold "+" or "-" button, 2s later, time will 

change quickly. Release this button when reaching your required time. Press

 "CLOCK" button to confirm the time. "     " icon stops blinking.

Note:

● Clock time adopts 24-hour mode.

 The interval between two operation can’t exceeds 5s. Otherwise, remote contro-

   ller will quit setting status. Operation for TIMER ON/TIMER OFF is the same.

CLOCK button

9

TIMER ON / TIMER OFF button

10

 TIMER ON button

   "TIMER ON" button can set the time for timer on. After pressing this button, "     "

   icon disappears and the word "ON" on remote controller blinks. Press "+" or "-" 

   button to adjust TIMER ON setting. After each pressing "+" or "-" button, TIMER 

   ON setting will increase or decrease 1min. Hold "+" or "-" button, 2s later, the 

   time will change quickly until reaching your required time. 

   Press "TIMER ON" to confirm it.

 The word "ON" will stop blinking. "     " icon 

   resumes displaying. Cancel TIMER ON: Under the condition that TIMER ON is

8

Press this button can select up&down swing angle. Fan blow angle can be selected 

circularly as below:

● When selecting "     ", air conditioner is blowing fan automatically

. Horizontal 

   louver will automatically swing up & down at maximum angle.

● When selecting "   

    

    

   

  ", air conditioner is blowing fan at fixed 

   position. Horizontal louver will stop at the fixed position.

● When selecting "     

   

   " , air conditioner is blowing fan at fixed angle. 

   Horizontal louver will send air at the fixed angle.

● Hold "    "button above 2s to set your required swing angle. When reaching your

   required angle, release the button.

Note:

● "    

   

   " may not be available. When air conditioner receives this signal, the 

   air conditioner will blow fan automatically.

    button

no display

(horizontal louvers stops

at current position)

6

Содержание MV-D BI Series

Страница 1: ......

Страница 2: ......

Страница 3: ...Contents 1 Safety Precautions 1 2 Operation of remote controller 3 3 Error Analysis 10 4 Maintenance 11 5 Safety operat ion of flammable refriger ant 12...

Страница 4: ......

Страница 5: ...minutes later after power recovery During installation the communication cable and the power cord must not be twisted together but instead separated with an interval of at least 2cm otherwise the unit...

Страница 6: ...it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased Th...

Страница 7: ...ose recommended by the manufacture Should repair be necessary contact your nea rest authorized Service Centre Any repairs carried out by unqualified personnel may be dangerous The appliance shall be s...

Страница 8: ...ge meanwhile it should be insulated to prevent condensing otherwise the improper installation would cause water leakage and then wet the household wares in the room Do not use or place any inflammable...

Страница 9: ...ening rod or phone cable s earth lead Turn off the unit after it runs at least five minutes otherwise its service life will be shortened Do not allow children operate this unit Do not operate this uni...

Страница 10: ...button Send signal Turbo mode X fan mode Set temperature Set time TIMER ON TIMER OFF Child lock Up down swing Set fan speed AIR function I feel Light Temp display type Set temp Outdoor ambient temp In...

Страница 11: ...de signal If setting heat mode with remote controller press ON OFF button can t start up the unit Note For preventing cold air after starting up heating mode indoor unit will delay 1 5 minutes to blow...

Страница 12: ...emperature or low temperature in order to avoid detecting inaccurate ambient temperature Press this button to set HEALTH function ON or OFF After the unit is turned on it defaults to HEALTH function O...

Страница 13: ...TIMER ON setting will increase or decrease 1min Hold or button 2s later the time will change quickly until reaching your required time Press TIMER ON to con rm it The word ON will stop blinking icon r...

Страница 14: ...tting time ON OFF button has no effect on setting If you don t need this function please use remote controller to cancel it X FAN button 11 12 Press this button under cool and dry mode to start up x f...

Страница 15: ...ss this button again to turn on display light icon is displayed SLEEP button LIGHT button 14 15 When selecting with remote controller temperature indicator on indoor unit displays outdoor ambient temp...

Страница 16: ...n of polar and polar are correct 3 Reinstall the cover of battery box signal sender battery Cover of battery box remove reinstall NOTICE During operation point the remote control signal sender at the...

Страница 17: ...ature is too high poor heating effect The air filter screen is too dirty or clogged The door or window is not closed fully The set temperature is too low uncontrollable controller If the remote contro...

Страница 18: ...oning unit is used under the environment with heavy dust the air filter should be cleaned often generally once every two weeks b Maintenance before seasonal use 1 Check if the air inlet outlet of the...

Страница 19: ...m 12 5 Safety operation of flammable refrigerant Qualification requirement for installation and maintenance man All the work men who are engaging in the refrigeration system should bear the valid cert...

Страница 20: ...UM This unit is containing fluorinated gases included in the Kyoto protocol The maintenance and the liquidation must be carried out by qualified personnel Type of refrigerant R32 The quantity of the r...

Отзывы: