If a roof vent opening is not used,a new opening(see figure 1)will be cut into the vehicl roof.
A matching opening will also have to be cut into the interior vehicle ceiling,be careful when 
cutting the ceiling opening because if the ceiling opening is carpeted,snagging could occur. After 
the opening in the roof and interior ceiling are the correct size,a framed support structure must 
be placed between the exterior roof top and interior ceiling.The reinforced framed structure must 
follow the follwing guidelines:

1.

It must be capable of supporting both the

weight of the roof top air conditioner and

the interior ceiling assembly.

3.

There must be an opening through the

frame for the power supply wiring.Route

the supply wiring through the frame at the

same time the support frame is being

installed.

2.

It must be capable of holding the roof outer

surface and interior ceiling apart and

supporting them, so that when the roof top

air conditioner and ceiling assembly are

bolted together,no collapsing occurs. A

typical support frame is shown in Figure 1.

CAUTION

1

.

The roof top air conditioner must be mounted on a level plane from front to rear and side to

side when the vehicle is parked on a level plane. Figure 

2

 shows maximum allowable degrees

that the unit can be mounted above or below level.

2

.

If the roof of the vehicle is sloped (not level) such that the roof top air conditioner cannot be

mounted within the maximum allowable degree specifications, an exterior leveling shim will

need to be added to make the unit level. A typical leveling shim is shown in Figure 

3

.

3

.

Once the roof top air conditioner has been leveled, some additional shimming may be required

above the interior ceiling assembly. The roof top air conditioner and the interior ceiling assembly

must be square with each other before they are secured together.

4

.

After the mounting hole area is properly prepared, remove the carton and shipping pads from

around the roof top air conditioner. Carefully lift the unit on top of the vehicle. Do not use the outer

plastic shroud for lifting. Place the roof top air conditioner over the prepared mounting hole.

5

.

The point end (nose) of the shroud must face toward the front of the vehicle.

Hole for

Wires

CASE B.

1

4

 -

Содержание ASV-25AS WIFI

Страница 1: ...CAMPER TRAILER ASV 25AS WIFI ASV 35AS WIFI USER S MANUAL EN...

Страница 2: ...t intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concern...

Страница 3: ...l or fumes in the air 5 The place with sulfureted gas 6 Other places with special circumstances 7 This air conditioner unit is only used for the vehicle without concave and convex surface on the top o...

Страница 4: ...roceeding any work related to electricity and safety 4 5 with specialized grounding device by a professional Please make sure it is always grounded effectively otherwise it may cause electric shock ca...

Страница 5: ...6 The Electric schematic diagram are subject to change without notice Please refer to which one on the unit Check the available power supply and resolve any wiring problems BEFORE installing and opera...

Страница 6: ...sembly YEGN YEGN PE PE M1 4YV VT VT 4WAY N CN5 IN_FAN AP1 MAIN BOARD BN OUT_FAN OUT_FAN1 BU N1 AC L1 YEGN POWER PE BU RD M2 M3 BU C YEGN YEGN PE PE OUTDOOR TUBE SENSOR TUBE SENSOR OUTROOM SENSOR 4 WAY...

Страница 7: ...8 remote controller Double sided gummed paper Sunk screw 2 remote controller holder Remote controller holder Foam up Foam accessory Sponge foam accessory Mounting plate sub assy Insulating sheath Bolt...

Страница 8: ...embrane LED TIMER ON Display content or position may be different from above graphics please refer to actual products LIGHT remote controller Outdoor Unit Outer case Air in grille Drainage outlet Chas...

Страница 9: ...ton TURBO button 13 SLEEP button 14 LIGHT button CLOCK button button ON OFF MODE _ FAN CLOCK LED TURBO TIMER OFF LIGHT TEMP SLEEP 13 Turbo mode Send signal Set temperature Set time TIMER ON TIMER OFF...

Страница 10: ...ed circularly Auto mode is default while power on Under Auto mode the temperature will not be displayed Under Heat mode the initial value is 28 82 Under other modes the initial value is 25 77 AUTO COO...

Страница 11: ...the wireless adjustable low fan speed is imperative button 7 Press this button the clock can be set up signal blink and display Within 5 seconds the value can be adjusted by pressing or button if cont...

Страница 12: ...l that will return to display the setting temperature if the users haven t set up the temperature displaying status that will display the setting temperature This function is applicable to partial of...

Страница 13: ...low fan speed 10s later the unit will turn off If start this function the unit will run at super high fan speed to cool or heat quickly so that the ambient temp approachs the preset temp as soon as p...

Страница 14: ...ote when it is powered on the guide louver of main unit will close automatically Pressing or button to set the desired temperatur It isunnecessary to set the temp at AUTO mode Pressing FAN button set...

Страница 15: ...e receiving window on indoor unit The distance between signal sender and receiving window should be no more than 8m and there should be no obstacles between them or wireless telephone remote controlle...

Страница 16: ...ating temperature of the 1 ON OFF button Operation starts when pressing this button and stops when pressing this button again 5 MODE button Select the operation mode COOL FAN HEAT 6 FILTER CHECK indic...

Страница 17: ...res Once the location for your air conditioner has been determined A reinforced and framed roof hole opening must be cut if there is no hole or you may use existing vent holes CASE A If a roof vent is...

Страница 18: ...ing occurs A typical support frame is shown in Figure 1 CAUTION 1 The roof top air conditioner must be mounted on a level plane from front to rear and side to side when the vehicle is parked on a leve...

Страница 19: ...x Below Level 0 Max Figure 2 Note Try you best to put the unit on the horizontal surface for operation The unit can only operate for a short time at the maximum sloping angle of 5 for preventing water...

Страница 20: ...ille at the back of outer case see Figure4 1 2 Fix the outdoor unit at the roof of vehicle and then drill holes 1 Place the outdoor unit at the roof of vehicle lift the outdoor unit and then place the...

Страница 21: ...long See fig 5 1 Then carry the outdoor unit to the vehicle s top and align with the openings on the vehicle s top Use 2 sets of mounting plate assembly and 4 screw bolts to mount the outdoor unit See...

Страница 22: ...foam Num 3 14mm sponge Num3 5mm wind path foam foam under fig 5 2 fig 5 3 STEP 4 ELECTRICAL WIRING ROUTING 220 240V AC WIRING 18 WARNING Make sure that all power supply to the unit is disconnected bef...

Страница 23: ...insulating jacket to enclose the wiring terminals and sponge Then glue the thermal insulating jacket and fasten it with cable ties Note 1 Cable ties must be attached to the area with both sponge and t...

Страница 24: ...tus 4 screw wind path front panel front grill fig 10 filter Install the healthy filter and air intake grill Press PUSH and lock with clasps 2 3 Check the thermostat position Make sure the thermostat i...

Страница 25: ...ear and side to side when the vehicle is parked Make sure that the mounting of the air conditioner is correct and level Reset the remote control to a lower temperature setting Remove and clean the fil...

Страница 26: ...core and insert it as Figure a is shown The inserted depth is about 3mm as shown in Figure c which the clasp is detachable When you hear a sound buckle the clasp base with your hands to take out the c...

Страница 27: ...iate length that fits your hand feeling WARNING FAILURE TO FOLLOWING INSTRUCTIONS COULD RESULT IN SERIOUS PERSONAL INJURY 2 Be careful when you maintain the refrigeration system which has the high int...

Страница 28: ...REFRIGERANT MEDIUM This unit is containing fluorinated gases included in the Kyoto protocol The maintanance and the liquidation must be carried out by qualified personel Type of refrigerant R410A The...