Malfunction analysis

● Power failure?
● Is plug loose?
● Air switch trips off or fuse is

   burnt out?

● Wiring has malfunction?
● Unit has restarted immediately 

   after stopping operation?

● Whether the function setting 

   for remote controller is 
   correct?

● Reset the function.

● Wait for 3min, and then turn

   on the unit again.

● Ask professional to replace it.

● Ask professional to replace 

   air switch or fuse.

● Reinsert the plug.

● Wait until power recovery.

Air condit-
ioner can’t 
operate

Mist is em-
itted from 
indoor unit’s 
air outlet

● Indoor temperature and hum-

   idity is high?

● Because indoor air is cooled 

   rapidly. After a while, indoor 
   temperature and humidity will 
   be decrease and mist will 
   disappear.

Phenomenon

Check items

Solution

Set temper-
ature can’t 
be adjusted

● Unit is operating under auto 

   mode?

● Temperature can’t be adju-

   sted under auto mode. 
   Please switch the operation 
   mode if you need to adjust 
   temperature.

● Your required temperature 

   exceeds the set temperature 
   range?

● Set temperature range: 

   16

~30

.

Cooling 
(heating) 
effect is 
not good.

● Voltage is too low?

● Wait until the voltage 

   resumes normal.

● Filter is dirty?

● Clean the filter.

● Set temperature is in proper

   range?

● Adjust temperature to proper

   range.

● Door and window are open?

● Close door and window.

24

Содержание ASH-13AIA PT

Страница 1: ...ARCTIC SERIES indoor unit ASH 13AIA PT ASH 18AIA PT USER S MANUAL ...

Страница 2: ... Original instruction ...

Страница 3: ...trol The remote controller shall be matched with the air conditioner before operation otherwise the remote control will be invalid Before operation please read the instructions in this page carefully and then do the corresponding matching operation Note When the unit is under standby status please get close to the air conditioner within 2m and then hold on pressing button for 3s The remote control...

Страница 4: ...ppliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Do not wash the air conditioner with water to avoid electric ...

Страница 5: ...damage Precautions WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not spill water on the remote controller otherwise the electric shock or damage Please contact dealer when you need to repair air conditioner Do not repair air conditioner by yourself It may cause object...

Страница 6: ...bles before using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket Properly connect the live wire neutral wire and any work related to electricity and safety Be sure to cut off the power supply before proceeding Including an circuit break with suitable capacity please...

Страница 7: ...onnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only Precautions WARNING wire which can t be used for other purposes The grounding resistance should comply with national electric safety regulations The air conditioner is the first class electric appliance It keep the interconnection cable away from the copper tube The temperature of refrige...

Страница 8: ...st be installed in the line For the air conditioner without plug an circuit break Select a location which is out of reach for children and For the air conditioner with plug the plug should be Working temperature range NOTICE Indoor side DB WB C Outdoor side DB WB C Maximum cooling 32 23 54 26 Maximum heating 27 24 18 The operating temperature range outdoor temperature for cooling is 18 54 The oper...

Страница 9: ...Indoor Unit air inlet panel filter power wire horizontal louver remote controller air outlet tem display power display NOTICE Actual product may be different from above graphics please refer to actual products 10 ...

Страница 10: ...ity button Health button Air button 10 T ON T OFF button 8 Mode button 5 Fan button battery power Send signal 8 heating function I feel function Set fan speed Temp display type Set temp Outdoor ambient temp Indoor ambient temp Heat mode Fan mode Dry mode Cool mode Auto mode Operation mode humidity functions Temp display type Healthy mode Set temperature INTELLIGENT HOUR ON OFF WIFI Up down swing L...

Страница 11: ...t will change accordingly Temperature can t be adjusted under auto mode Introduction for buttons on remote controller Note After putting through the power the air conditioner will give out a sound Operation indictor is ON red indicator After that you can operate the air conditioner by using remote controller Under on status pressing the button on the remote controller the signal icon on the displa...

Страница 12: ...as below I FEEL button 6 Press this button to start I FEEL function and will be displayed on the remote controller After this function is set the remote controller will send the detected ambient temperature to the controller and the unit will automatically adjust the indoor temperature according to the detected temperature Press this button again to close I FEEL function and will disappear Please ...

Страница 13: ...ting mode the air conditioner operates under heat mode Press or button to adjust set temperature Press FAN button to adjust fan speed Press button to adjust fan blowing angle Cooling only unit won t receive heating mode signal If setting heat mode with remote controller press ON OFF button can t start up the unit Note For preventing cold air after starting up heating mode indoor unit will delay 1 ...

Страница 14: ...resumes displaying Cancel T OFF Under the condition that T OFF is started up press T OFF button to cancel it Note Under on and off status you can set T OFF or T ON simultaneously Before setting T ON or T OFF please adjust the clock time After starting up T ON or T OFF set the constant circulating valid After that air conditioner will be turned on or turned off according to setting time ON OFF butt...

Страница 15: ...L or DRY mode the icon is displayed and the indoor fan will continue operation for 2 minutes in order to dry the indoor unit even though you have turned off the unit After energization X FAN OFF is defaulted X FAN is not available in AUTO FAN or HEAT mode This function indicates that moisture on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould Having set X FAN func...

Страница 16: ...d on the features of siesta press AIR button to confirm the setting Note In the above setting or inquiry procedure if there is no button pressing within 10s remote controller will automatically exit the sleep curve setting and resume the original display If ON OFF MODE TIMER HUMIDIFY SLEEP COOLING or HEATING button is pressed during the setting or inquiry procedure remote controller will also exit...

Страница 17: ... turning off the unit by pressing ON OFF button About AUTO RUN When AUTO RUN mode is selected the setting temperature will not be displayed on the LCD the unit will be in accordance with the room temp automatically to select the suitable running method and to make ambient comfortable About lock Press and buttons simultaneously to lock or unlock the keyboard If the remote co ntroller is locked the ...

Страница 18: ...r of battery box signal sender battery Cover of battery box remove reinstall NOTICE During operation point the remote control signal sender at the receiving window on indoor unit The distance between signal sender and receiving window should be no more than 8m and there should be no obstacles between them Signal may be interfered easily in the room where there is fluorescent lamp or wireless telep...

Страница 19: ...maintenance Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not wash the air conditioner with water to avoid electric shock Do not use volatile liquid to clean the air conditioner Clean surface of indoor unit When the surface of indoor unit is dirty it is recommended to use a soft dry cloth or wet cloth to wipe it NOTICE Do not r...

Страница 20: ...nto a certain angle less than 60 do not open the panel too forcibly along the arrow direction from the two sides of panel the water below 45 to clean it and then put it in a shady and cool place to dry panel cover tightly operation environment clean frequency can be increased WARNING 21 ...

Страница 21: ...l method 1 Check whether air inlets and air outlets are blocked 2 Check whether air switch plug and socket are in good condition 4 Check whether mounting bracket for outdoor unit is damaged or corroded If yes please contact dealer 5 Check whether drainage pipe is damaged 1 Disconnect power supply 3 Check whether mounting bracket for outdoor unit is damaged or corroded If yes please contact dealer ...

Страница 22: ...m Pull out the plug Reinsert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re ceiving window on indoor unit Check the batteries If the power of batteries is too low please replace them Take the remote controller close to indoor unit Turn off the fluoresent lamp and then try it again...

Страница 23: ...temperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set temper ature can t be adjusted Unit is operating under auto mode Temperature can t be adju sted under auto mode Please switch the operation mode if you need to adjust temperature Your required temperature e...

Страница 24: ...it again Outdoor unit has vapor Heating mode is turned on During defrosting under he ating mode it may generate vapor which is a normal phenomenon Water flowing noise Air conditioner is turned on or turned off just now The noise is the sound of refrigerant flowing inside the unit which is a normal phenomenon Cracking noise Air conditioner is turned on or turned off just now This is the sound of fr...

Страница 25: ...restarting the unit If not please It can be eliminated after restarting the unit If not please When below phenomenon occurs please turn off air conditioner and discon for service Power cord is overheating or damaged There s abnormal sound during operation Air switch trips off frequently Air conditioner gives off burning smell Indoor unit is leaking If the air conditioner operates under abnormal co...

Страница 26: ...Installation dimension diagram At least 250cm At least 15cm At least 300cm Space to the ceiling Space to the obstruction At least 15cm At least 15cm Space to the wall Space to the wall 27 ...

Страница 27: ...allation location 1 Level meter 2 Screw driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench 7 Open end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 12 Universal meter 13 Inner hexagon spanner 14 Measuring tape Note Please contact the local agent for installation Basic requirement Indoor unit Installing the unit in the following pla ces maycause malfunctio...

Страница 28: ...aced by the manufacturer its 8 The temperature of refrigerant circuit will be high please keep the interconnec tion cable away from the copper tube 9 The appliance shall be installed in accordance with national wiring regulations grounding with specialized grounding device by a professional Please make sure it is always grounded effectively otherwise it may cause electric shock 2 The yellow green ...

Страница 29: ...ould be a little lower than the wall mounted frame shown as below Step three open piping hole 2 Open a piping hole with the diameter of Φ55 on the selected outlet pipe position In order to drain smoothly slant the piping hole on the wall slightly downward to the outdoor side with the gradient of 5 10 13K 18K Left Wall Φ55mm Right Mark in the middle of it Level meter Rear piping hole Wall Space to ...

Страница 30: ...g out the pipe from left or right please cut off the corresponding hole on the bottom case cut off the hole left right 1 The pipe can be led out in the direction of right rear right left or rear left left rear left right rear right Step four outlet pipe Installation of indoor unit union nut pipe joint pipe Note Pay attention to dust prevention and take relevant safety measures when opening the hol...

Страница 31: ... 45 55 60 65 70 75 15 20 insulating pipe 1 Connect the drain hose to the outlet pipe of indoor unit 2 Bind the joint with tape outlet pipe drain hose drain hose tape outlet pipe drain hose insulating pipe Note Add insulating pipe in the indoor drain hose in order to prevent condensation The plastic expansion particles are not provided 1 Open the panel remove the screw on the wiring cover and then ...

Страница 32: ... than 3mm 3 Remove the wire clip connect the power connection wire to the wiring terminal with wire clip After finishing wiring of 18K unit clamp the grounding wire yellow green wire into the wire crossing groove as shown in the following figure in order to avoid pressing the wire when closing the electric box cover power connection wire cable cross hole 2 Make the power connection wire go through...

Страница 33: ...rately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom drain hose band connection pipe indoor power cord Step nine hang the indoor unit 1 Put the bound pipes in the wall pipe and then make them pass through the wall hole 2 Hang the indoor unit on the wall mounting frame 3 Stuff the gap between pipes and wall hole with sealing...

Страница 34: ...ant charging vent 2 Connect the charging hose of piezometer to the refri gerant charging vent of gas valve and then connect the other charging hose to the vacuum pump 3 Open the piezometer com pletely and operate for 10 15min to check if the pressure of piezometer re mains in 0 1MPa 4 Close the vacuum pump and maintain this status for 1 2min to check if the pres sure of piezometer remains in 0 1MP...

Страница 35: ...it grounded securely It may cause electric leakage Does the power cord follow the speci fication It may cause malfunction or damaging the parts Is there any obstruction in the air inlet and outlet It may cause insufficient cooling heating capacity The dust and sundries caused during installation are removed It may cause malfunction or damaging the parts The gas valve and liquid valve of connection...

Страница 36: ...nt charging amount per meter When the length of connection pipe is above 5m add refrigerant according to the prolonged length of liquid pipe The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Cooling capacity Cooling capacity 5000Btu h 1465W 24000Btu h 7032W 7000Btu h 2051W 28000Btu h 8204W 9000Btu h 2637W 36000Btu h 1...

Страница 37: ...ction pipe Liquid pipe mm Gas pipe mm Φ6 Φ6 or Φ9 52 Φ12 Φ16 Φ19 Φ22 2 Φ9 52 or Φ12 Φ16 or Φ19 Φ19 or Φ22 2 Φ25 4 or Φ31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350 120 120 50 20 Outdoor unit throttle Configuration of connection pipe 38 ...

Страница 38: ...itable insulating pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe union pipe pipe E Expand the port Expand the port with expander Note A is different according to the diameter please refer to the sheet below expander hard mold pipe F Inspection Check the quality of expanding port If there is any blemish expand the p...

Страница 39: ...40 ELECTRIC SCHEMATIC DIAGRAM ASH 13AIA PT indoor ASH 18AIA PT indoor ...

Страница 40: ...41 RATING LABEL ...

Страница 41: ...42 ENERGY LABEL ...

Страница 42: ...is located INFORMATION CONCERNING USED REFRIGERANT MEDIUM This unit is containing fluorinated gases included in the Kyoto protocol The maintanance and the liquidation must be carried out by qualified personel Type of refrigerant R410A The composition of the cooling medium R410A 50 HFC 32 50 HFC 125 The quantity of the refrigerant please see the unit label The value GWP 2088 GWP Global Warming Pote...

Отзывы: