3. ELECTRIC SCAFETY REQUIREMENT
NOTE
Do not cut off the ground wire of the main power switch in any
circumstance.
Do not use damaged power wires. Change the damaged power
wires once they are detected.
Connect the power supply of the air conditioner for preheating it
for at least 12 hours before using the air conditioner. Besides
that, please be keep in mind that do not cut off the power supply
immediately, for the unit completely shut down needs to spend a
day-night.( In order to prevent the compressor drive-up by
forced, then heating the crankcase.)
Do not block the air inlet and outlet, if that so the performance
would reduce and the unit couldn’t be start for which protect
device is on service.
Wire distribution must be performed by duly qualified electri-
cians.
All wire distribution must comply with electric safety specifica-
tions.
Ensure that the air coditioner is grounded properly. Namely, the
main switch of the air conditioner must have reliable ground
wires.
Provide the air conditioner with a separate power supply compli-
ant with the nominal parameter values.
Electric performance requirements:
4. FUNCTIONS & FEATURES
Nested in the ceiling, space-saving and noble.
High capacity of cooling/heating, efficient, and energy-saving.
Innovative air supply, which provides homogeneous condition-
ing of the room temperature.
Remote control or wire control function.
Low noise design,the A-weighted sound pressure level is
below 70 dB.
The air outlet is laid out in the way you desire.
Use refrigerant to transmit cool/heat directly, which provides a
high transmitting efficiency.
It is suitable be used for office, hospital, commerical place and
home, the air conditioner will creat the comfortable and
elegance enviroment for you.
Table 3-1
Type
Power
supply
The main
switch
specification
Indoor
unit
Outdoor
unit
Fuse
specification
Fig.5-1
5. NAMES AND FUNCTIONS OF AIR
CONDITIONER COMPONENTS
outdoor unit
Refrigerant pipe
Indoor unit
Electrical control box
Remote controller
Air outlet pipe, mute box(option)
Air return duct(option)
Remote controls signal
reciving board
Fixed rated wire controller
220-240V~
ASDH-96AI
50Hz
16A
16A
380-415V 3N~
ASDH-96AI
40A
40A
50Hz
(Option.)
NOTE
12 hours preheating is imperative after turn on the power
switch. Please do not shut down the power when the unit
is supposed to stop running in 24h or shorter time. (This is
to warm the crankcase heat box to avoid compulsive start
of condenser.)
Pay attention not to block the air inlet and outlet.
Blocks may decrease the efficiency of the unit or startup the
protector, which will stop running.