background image

No

Description 

Part Code 

Note

Qty 

Price 
Code 

1 Decorative Board sub-assy

20196011

1

AN

2 Decorative Board

20196006S

1

AK

3 Decorative Block

20196013

1

AC

4 Decorative Strip

20196012

1

AE

5 Front Panel

20006059

1

AW

6 Front Panel Sub-Assy

20006061

1

AL

7 Display Board

30567012

1

AS

8 Button

45036021

1

AE

9 Fan Motor

1501603903

1

AY

10 Motor holder (upper)

26156043

1

AU

11 Electric Box Assy

01406016

1

BC

12 Main Board

30137003

1

AZ

13 Ambient Temperature Sensor

390000451

1

AD

14 Tube Sensor

390000594

1

AD

15 Transformer

43110295

1

AH

16 Capacitor CBB65

33010743

1

AK

17 Capacitor CBB61

33010027

1

AE

18 Capacitor CBB61

33010025

1

AE

19 Electric Box Cover

01416010

1

AD

20 Chassis Sub-assy

01206038P

1

AF

21 Gear Sub-Assy

10546005

1

AC

22 Centrifugal Fan

10316058

1

AM

23 Guide Louver 1

10516051

1

AD

24 Guide Louver 2

10516052

1

AD

25 Diversion Circle (upper)

10376035

1

AE

26 Stepping Motor

1521210301

1

AF

27 Left Axile Bush

10512037

3

AB

28 Mid-Clapboard

20056095

1

AL

29 Water Tray

20186072

1

AM

30 Evaporator Assy

01006050

1

BH

31 Filter Sub-assy

11126011

1

AD

32 Rear Plate Sub-Assy

20056105

1

AU

33 backboard 1

20056096

1

AR

34 Remote control box

20116012

1

AD

35 Cover of Remote control box

20126072

1

AE

36 Cable Cross Plate

26116060

1

AD

37 Female Clip

70810302

1

AB

38 Condenser Assy

0110610301

1

BK

39 Motor holder b (lower)

26156046

1

AP

40 Fan Motor

1501603902

1

AY

41 Centrifugal Fan

10316058

1

AM

42 Diversion Circle (lower)

10376034

1

AP

43 Discharge Tube

03616079

1

AG

44 Capillary Sub-Assy

03006095

1

AU

45 Inhalation Tube

03626095

1

AK

46 Compressor and Fittings

00103781

1

BL

PART 1

MODEL: AMC-12AN

Содержание AMC-12AN

Страница 1: ...SERVICE MANUAL AMC 12AN MOBILE SERIES ...

Страница 2: ......

Страница 3: ...Summary and features MODEL AMC 12AN FAN AUTO OPER HEALTH AIR FILTER TURBO ON OFF BLOW HOUR HUMIDITY ON OFF MODE FAN BLOW TURBO TEMP TIMER SLEEP LIGHT YB1F2 ...

Страница 4: ...ap 3 1 6 Coil length l x height H x coil width L 363X285X38 1 Swing Motor Model MP28GA Output of Swing Motor W 28 Fuse A PCB 3 15A Sound Pressure Level dB A H M L 58 56 52 Indoor Side EER C O P W W Energy Class Air Flow Volume m3 h H M L Dehumidifying Volume l h Total Capacity W Btu h Power Input W Rated Input W Rated Current A Function Rated Voltage Rated Frequency Model Product Code 2 Specificat...

Страница 5: ...e Excessive Operating Pressure for the Discharge Side MPa Permissible Excessive Operating Pressure for the Suction Side MPa Output of Fan Motor W Fan Motor RLA A Fan Motor Capacitor ȝF Climate Type Sound Pressure Level dB A H M L Sound Power Level dB A H M L Defrosting Method Fan Motor Speed rpm H M L Rows Fin Gap mm Coil length l x height H x coil width L Fan Type Piece Fan Diameter mm Starting M...

Страница 6: ...Model AMC 12AN Front Rear Air outlet Controller panel Handle Remote box Upper air inlet grille Air exhaust outlet Lower air inlet grille 3 Construction Views ...

Страница 7: ...Outline and installation dimension Unit 460 Model AMC 12AN 4 Outline and installation Dimension ...

Страница 8: ...5 Refrigerant System Diagram HEAT EXCHANGE EVAPORATOR COMPRESSOR ...

Страница 9: ...Model AMC 12AN 6 1 Electrical wiring 6 Schematic Diagram ...

Страница 10: ...6 2 Printed Circuit Board Models AMC 12AN 6 2 1 Dispay board TOP VIEW BOTTOM VIEW ...

Страница 11: ...OOM Temperature for indoor pipe TUBE Swing motor SWING Compressor relau K201 Zero line copper fin N3 Transformer output TR OUT Zero line copper fin N1 N2 Protective tube FU201 Piezoresistance RV201 Transformer input TR IN Indoor fan motor FAN Outdoor fan motor FAN Kick motor control WATER Model AMC 12AN 6 2 2 Control board ...

Страница 12: ...and down button below Press this button the running mode will change as Mode button MODE FAN AUTO OPER HEALTH AIR FILTER TURBO ON OFF BLOW HOUR HUMIDITY ON OFF MODE FAN BLOW TURBO TEMP TIMER SLEEP LIGHT could turn on or turn off the Up and down swing function When unit is turned off synchronously press and Up and down swing buttons it could be switched between the simpleness swing mode and station...

Страница 13: ... off will stop flickering If the time of that no press timer button under flickering status is above 5s the timer setting will quit If the timer has been set press this button once again to quit it press this key once again to fix the time There is no this function for this unit If press this key the main unit will click but it also runs under original status Temp display button TEMP Save energy f...

Страница 14: ... in the displayer When the LIGHT is on the icon will be displayed and the indi cators light in the displayer will be on When the LIGHT is off the icon will be disappeared and all the indicators light in the displayer will be off Light button LIGHT Press this button enter into SLEEP state when repressed it will quit The sleep function and FAN mode will be canceled with the stop of the unit There is...

Страница 15: ...on to set Blow function on or off 5 Press TURBO button to set this function on or off Guide for operation optional operation Introduction for special function This function indicates that moisture on evaporator of indoor unit will be blowed after the unit About blow function is stopped to avoid mould 1 Having set blow function on After turning off the unit by pressing ON OFF button indoor fan will...

Страница 16: ...position on remote controller will display H1 If switch to heat mode the position will display H1 which flickers for 5s in which case press button H1 will disappear and setting temp be displayed After remote controller is powered on the new defrost function will be defaulted to be closed ƾ ƾ ƾ ƾ ƾ About lock About AUTO RUN About new function of defrosting The appliance of the defrosting function i...

Страница 17: ...mpressor is started the unit is off without the temperature change in 6min Ƶ Working conditions and process of cooling a When Tabm Tpreset 1ć 2 the unit will start to run in cooling mode the compressor and kick motor start to run and fan motor runs under preset fan speed b When Tabm Tpreset 1ć 2 the compressor and kick motor stop to run and fan motor runs under preset fan speed c When Tpreset 1ć 2...

Страница 18: ...4 2 Med fan ć Tamb T preset Low fan b There is 3 5min delay for auto fan shift Ŷ TIMER Function Ɣ General timer a TIMER ON It can set timer on when the system is off the setting time range is 0 5h 24h when the time of setting timer on reaches and the system runs with the previous setting mode b TIMER OFF It can set timer on when the system is on the setting time range is 0 5h 24h when the time of ...

Страница 19: ...compressor stops fan motor runs with setting fan speed When the anti freeze protection is canceled and reaches to the 3min time delay it runs with the original status Temperature sensor failure inspection e Environment temperature sensor is open short circuit dual 8 displays F1 the cooling indicator lamp goes out 3S and blinks 1 time and it will light up 0 5S and go out 0 5S when it is blinking f ...

Страница 20: ...Failure Display Code Failure Name Dual 8 Display Indicator Lamp Repair Method 1 Environment temperature sensor is open short circuit F1 Cooling indicator lamp goes out 3S blinks 1 time and lights up 0 5S goes out 0 5S If loose text resistance value if normal by universal meter 2 Temperature sensor for indoor pipe temperature is open short circuit F2 Cooling indicator lamp goes out 3S blinks 2 time...

Страница 21: ...utdoor unit is good Check the flow process of failure is Turn on the unit Display Display Replace control board Replace control board board control Replace Check if the indoor temperature sensor is connected tightly Check if the indoor temperature sensor s connected tightly i Replace temperaure sensor Replace temperaure sensor Adjust connection Adjust connection Failure is cancelled Failure is can...

Страница 22: ...r level switch is damaged Check the flow process of failure is Turn on the unit Display H8 If the defrosting tray is over blow Refer to the indication of instruction to discharge the water of chassis Connection line of water level switch is tight Failure is cancelled Adjust connection Failure is cancelled Replace the switch of water level Failure is cancelled Replace control board End ...

Страница 23: ... point ƽ If the motor does not rotate Check the flow process of failure is Turn on the unit Motor does not rotate If the connection line is tight Replace control board Adjust connection Failure is cancelled Failure is cancelled Replace control board Replace motor Failure is cancelled End ...

Страница 24: ...k the switch of water level and circuit Turn on the fan and the compressor does not start up Turn on or turn off compressor frequently under cooling or dry mode abnormal anti freeze protection Filter is dirty Clean the filter The inlet and outlet port are blocked Move the barrier or move the unit ro empty place The rotational speed of fan is slow or fan does not rotate Check if the fan motor s sup...

Страница 25: ...the connection wire of motor is loosen and failure for capacity or motor Set cooling dry mode but no cool air blow out Indoor temperature is less than preset temperature under cooling Normal phenomena adjust lower preset temperature Evaporator is frosting The system is defrost and abnormally runs after defrost Abnormal noise Sparepart is loose Bind the spareparts The fan is decentred Replace the f...

Страница 26: ...t note need lift at full tilt because of clasps on both sides clasp display plate Disassemble front panel 1 Disassemble front panel unscrew the 7 screws of front panel lift the panel upwards to remove it 2 Separate panel after lift front panel remove the display of panel from clasp then the front panel can be separated 11 Removal Procedure ...

Страница 27: ... 5 screws on the rear and both sides per 1 screw break the clasps of both sides outwards to remove the rear panel Disassemble electric box 1 Disassemble electric box unscrew the 3 screws of electric box cover to remove the electric box cover 2 After remove the electric box cover pull out the related electric wire cut the wire clip and unscrew the 3 screws of the electric box to remove the electric...

Страница 28: ... whole subassembly Disassemble supporting plate Unscrew the related screws of supporting plate to remove the supporing plate middle inner cover Disassemble bottom duct subassembly Unscrew the screw of middle inner cover first then unscrew the 9 screws of bottom duct subassembly after unscrew the screw lift a little middle inner cover to remove the bottom duct subassembly ...

Страница 29: ... motor fan Disassemble electric heating subassembly not valid for cooling unit 1 Disassemble electric heating shell unscrew the 4 screws of electric heating shell then it can be separated from top duct subassembly 2 Disassemble unscrew the 4 screws of electric heating subassembly to remove the electric heating subassembly step motor Disassemble protection grill nets 1 Disassemble step motor unscre...

Страница 30: ...screw to remove the protection grill nets refer to the right diagram to see the screw position protection grill nets screw position Disassemble bottom duct motor 1 Disassemble propeller housing unscrew the 4 screws of propeller housing to remove the propeller housing 2 Disassemble fan bottom unscrew the nut of a fan and remove the two gaskets to remove the fan 3 Disassemble motor after remove the ...

Страница 31: ...ssor and remove the related gasket to remove the compressor Disassemble kick motor subassembly Unscrew the 2 screws on the outside bottom of subassembly to remove the kick motor subassembly Disassemble liquid level switch Unscrew the 2 screws of subassembly to remove the liquid level switch ...

Страница 32: ...PARTS GUIDE AMC 12AN MOBILE SERIES ...

Страница 33: ... ...

Страница 34: ...9 1 Exploded View Model AMC 12AN ...

Страница 35: ...21 Gear Sub Assy 10546005 1 AC 22 Centrifugal Fan 10316058 1 AM 23 Guide Louver 1 10516051 1 AD 24 Guide Louver 2 10516052 1 AD 25 Diversion Circle upper 10376035 1 AE 26 Stepping Motor 1521210301 1 AF 27 Left Axile Bush 10512037 3 AB 28 Mid Clapboard 20056095 1 AL 29 Water Tray 20186072 1 AM 30 Evaporator Assy 01006050 1 BH 31 Filter Sub assy 11126011 1 AD 32 Rear Plate Sub Assy 20056105 1 AU 33 ...

Страница 36: ... Water Level Switch 45010211 1 AL 54 Castor 24236051 4 AC 55 Motor Sub assy Flutter 15006032 1 AZ 56 Fan Motor 150162122 1 AX 57 Pump Fan 10336003 1 AL 58 Exhaust Pipe Sub Assy 05236034 1 AT 59 Rear Clip 2611601001 1 AF 60 Remote Controller 305100611 1 AT 61 Power Cord 400204648 1 AF 62 Drain Pipe 05230013 3 Crank 10582070 1 Tie in 1 06646021 1 Joint3 26116064 1 Foam Propeller Housing 12316036 1 P...

Отзывы: