background image

 
 
 
 

SINBON Electronics Co., Ltd. 

4F-13, No. 79, Sec. 1, Hsin Tai Wu Rd., 
Hsi-Chih, Taipei Hsien 221, Taiwan 
Tel: +886-2 2698-9999 Fax: +886-2 2698-9660 
www.sinbon.com

 

12. Safety Notices. 

(1). Follow these instructions. 

(2). Heed all warning. 

 

WARING:  The installation  and repair service should be provided only by a qualified service 

technician!

 

 

WARING:

 

The  device is not direct  for outdoor application. Please the installation conditions must 

have at indoors or inside the outdoor control box!

 

 

WARNING: Avoid using this product during an electrical storm. There may be a remote risk of 

electric shock from lightning!

 

 

WARING:  Compliance is required with respect to voltage, frequency, and current requirements 

indicated on the manufacturer’s label. Connection to a different power source than those specified 

may result in improper operation, damage to the equipment or pose a fire hazard if the limitations 

are not followed! 

 

13. FCC Statement 

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 

of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a 

residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed 

and used in accordance with the instructions, may cause harmful interference to radio communications. However, 

there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful 

interference to radio or television reception, which can be determined by turning the equipment off and on, the user 

is encouraged to try to correct the interference by one or more of the following measures: 

—Reorient or relocate the receiving antenna. 

—Increase the separation between the equipment and receiver. 

—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 

—Consult the dealer or an experienced radio/TV technician for help. 

FCC Radiation Exposure Statement 

This device complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment 

must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter 

must be installed to provide a separation distance of at least 20 cm from all persons. 

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 

(1) this device may not cause harmful interference, and 

(2) this device must accept any interference received, including interference that may cause undesired operation. 

Caution! 

Any changes or modifications not expressly approved by the party responsible for compliance could void the user's 

This document contains confidential and proprietary information, all information are reserved by SINBON Electronics Co., LTD.

 

 

20 

Содержание SG-70

Страница 1: ...w sinbon com SG 70 Solar Gateway User s Quick Start Guide Version 1 0 Date Feb 08 2018 DMIS RD Department User s Guide Data Sheet Operation Manual Approved by Reviewed by Prepared by Bruce Lin Asuka Wu Happy Chen This document contains confidential and proprietary information all information are reserved by SINBON Electronics Co LTD 1 ...

Страница 2: ...r s Start Guide Doc No M 170061 Revision Notes Date Status Comments 1 0 Feb 08 2018 Preliminary release We reserve all rights in this document and in the information contained therein Reproduction use or disclosure to third parties without express authority is strictly forbidden This document contains confidential and proprietary information all information are reserved by SINBON Electronics Co LT...

Страница 3: ...ar Gateway installation 5 5 The Solar gateway basic local network configuration 15 6 LED Status descriptions 17 7 Reset to the factory default setup instruction 17 8 Troubleshooting 18 9 Product specifications 18 10 Label 19 11 Dimension 19 12 Safety Notices 20 13 FCC Statement 20 Contents This document contains confidential and proprietary information all information are reserved by SINBON Electr...

Страница 4: ...is designed to guide you through the installation and setup of this product 2 Package contents 1 2 3 4 5 SG 70 Solar Gateway 1pcs 5 dBi Dipole Antenna 1pcs Waterproof connector 1set M4 0 7 12 Brss screw 4pcs Clamp core for Ethernet cable 1pcs 3 Hardware overview This document contains confidential and proprietary information all information are reserved by SINBON Electronics Co LTD 4 ...

Страница 5: ...aults Ethernet port This Ethernet port is connect to the POE port at the POE adapter the POE LAN port connector to your network router or connector to PC or NB can set up DHCP 4 Solar Gateway installation Installation Checklist SG 70 Solar gateway 1 pcs In the Solar gateway package POE adapter 1 pcs without attach the device need to check installation status Antenna 1 pcs In the Solar gateway pack...

Страница 6: ...tions must have at indoors or inside the outdoor control box WARING Service should be provided only by a qualified service technician The LAN port used Ethernet cable assembly with waterproof connector the kits have 4 parts Please do not discard the waterproof washer It will be used later Step1 The LAN cable through the part 1 This document contains confidential and proprietary information all inf...

Страница 7: ...i Hsien 221 Taiwan Tel 886 2 2698 9999 Fax 886 2 2698 9660 www sinbon com Step2 The LAN cable through the part 2 Step3 The LAN cable through the part 2 This document contains confidential and proprietary information all information are reserved by SINBON Electronics Co LTD 7 ...

Страница 8: ...8 9999 Fax 886 2 2698 9660 www sinbon com Step4 The L part 3 through the part 2 Step5 The part 1 Spin pre installation and lock into the part 3 assembly complete Please don t lock it This document contains confidential and proprietary information all information are reserved by SINBON Electronics Co LTD 8 ...

Страница 9: ...8 9660 www sinbon com Step6 The waterproof connector kits part 4 waterproof washer set on the Ethernet port at the Solar gateway Step7 Connect the Ethernet cable to the Ethernet port at the Solar gateway This document contains confidential and proprietary information all information are reserved by SINBON Electronics Co LTD 9 ...

Страница 10: ...p8 First lock the waterproof connector part 3 until to locked then until locked the part1 Step9 The Second LAN cable for WAN port used after the RJ45 connector front end 12cm the Ethernet cable around 1 circle on the clamp core This document contains confidential and proprietary information all information are reserved by SINBON Electronics Co LTD 10 ...

Страница 11: ...nbon com Step10 Connect the POE Adapter power cord to AC power 100 240V 50 60Hz after connecting the blue light LED is fixed light Step11 The LAN ports Ethernet cable is connect with the POE port at the POE adapter This document contains confidential and proprietary information all information are reserved by SINBON Electronics Co LTD 11 ...

Страница 12: ...886 2 2698 9999 Fax 886 2 2698 9660 www sinbon com Step12 The WAN port Ethernet cable is connect with the LAN port at the POE adapter and others side connect to the PC or NB This document contains confidential and proprietary information all information are reserved by SINBON Electronics Co LTD 12 ...

Страница 13: ...21 Taiwan Tel 886 2 2698 9999 Fax 886 2 2698 9660 www sinbon com Step13 Use screws locked the Solar gateway on the wall Pure wall hanging type box hanging type This document contains confidential and proprietary information all information are reserved by SINBON Electronics Co LTD 13 ...

Страница 14: ...nstallation Antenna confirm the locked Waterproof connector confirm the locked POE adapter 2 LAN cable confirm the connected POE adapter power cord confirm the connected Solar gateway power LED is light Database activity and Wireless activity LEDS after complete all system setting will be function in the stage no light is right This document contains confidential and proprietary information all in...

Страница 15: ...cian 5 1Fixed IP address mode set up steps Step1 Change the Router local network TCP IP address please enter to the same area as Gateway E g IP address 192 168 0 1 Step2 Open browser key in the URL http 192 168 0 100 after complete press enter In the login page enter the following information complete press Login User Name admin Password admin This document contains confidential and proprietary in...

Страница 16: ...an compare to time E g pool ntp org VPN Server IP Address Enter the URL for the VPN option Confirm finish to setup enter confirm Automatically link to the new URL http 192 168 0 100 In the login page enter the following information complete press Login User Name admin Password admin Step4 In the wire page the local networks default setting as follows Change DHCP setup to ON finish enter the Confir...

Страница 17: ...ed Fixed off The device no connect with database Light blinks The device data is transmitting to database Wireless LED Fixed light The device is connect with sensor and transmits data to far end database Fixed off No connect with sensor or no data transmits to far end database 7 Reset to the factory default setup instruction Step1 At the system turn on mode press and hold the SG 70 the reset butto...

Страница 18: ...atus 9 Product specifications SG 70 Solar gateway specifications Dimensions L x W x H 185 x 167 x 45 mm without cable and antenna length Weight 0 373 kg Processor NXP i MX6 Solo 1GHz Memory DDR3L 1GB Storage NAND Flash 8GB Ethernet 100Mbps RJ45 Ethernet port Wireless IEEE802 15 4 LEDs 3 LEDS Power Database connectivity Wireless connectivity Button Reset button Max power 6W Max Power supply AC 100 ...

Страница 19: ...Fax 886 2 2698 9660 www sinbon com 10 Label Item Description 1 Label location A9310451 001 SG 7 0 Label location_201 2 Certification label A9310451 001 SG 7 0 Reg label_2017120 11 Dimension This document contains confidential and proprietary information all information are reserved by SINBON Electronics Co LTD 19 ...

Страница 20: ...nterference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the recei...

Страница 21: ... Wu Rd Hsi Chih Taipei Hsien 221 Taiwan Tel 886 2 2698 9999 Fax 886 2 2698 9660 www sinbon com authority to operate the equipment This document contains confidential and proprietary information all information are reserved by SINBON Electronics Co LTD 21 ...

Отзывы: