4.3
Accept mode activation ALL - SIN.EQRPT868XT
a)
It is used when the commissioning is carried out after with respect to the installation of the heat
cost allocators
b)
To activate the accept ALL mode on a newly installed SIN.EQRPT868XT
1.
Press button 2 (2s. < T < 6s)
2.
When pressing button 2, the LED (8.1) flashes every second. When the key 2 is released, the LED
(8.1.) remains lit to indicate the activation of the accept ALL mode.
3.
RPT receives and takes charge of all devices transmitting in W.M-Bus including frames in
Installation Mode (SND_IR) - The first green LED lights up permanently - Scan duration without
user intervention 12 hours
4.
press the button 2 (no coded pressure time) to stop the scan manually
Note: if during the scan the RPT connects into the MESH network the mode of operation will automatically
change with the value set on the RTU.